4 Maintenance

4.1 Air Filter

The Phoenix R150 is equipped with a pleated media air filter 

that must be checked regularly. The standard filter is a MERV-

8 high efficiency filter. Operating the unit with a dirty filter will 

reduce the dehumidifier’s capacity and efficiency and may 

cause the compressor to cycle off and on unnecessarily. The 

filter can generally be vacuumed clean several times before 

needing replacement. Replacement filters can be ordered 

from the manufacturer or purchased locally if available 

IMPORTANT: DO NOT operate the unit without the filter or 
with a less effective filter as the coils inside the unit could 
become clogged and require disassembly to clean.

4.2 Storage

There are two issues to consider when the Phoenix  

R150 is stored between uses and both pertain to the water 

trapped in the unit: damage caused by freezing or biological 

growth. The effect of the trapped water can be greatly 

reduced if precautions are taken to remove as much as 

possible before storage.
1.   Use the pump PURGE button to reduce the water level in 

the reservoir

2.   Walk out the hose to drain it completely
In order to reduce biological growth flush the unit with a 

biofungicide that is approved for use with copper, aluminum, 

polyethylene and ABS. To flush:
1.   Run the hose to a drain
2.   Plug in the unit but do not turn it on
3.   Remove the air filter. Slowly pour a pint of the chemical 

through the top so that it drains into the heat exchanger

4.   Use PURGE button to remove chemicals in reservoir. Run 

PURGE until hose runs dry

5.   Walk out hose to drain completely
6.   Replace air filter

5 Service

WARNING: Servicing the Phoenix R150 with its high 
pressure refrigerant system and high voltage circuitry 
presents a health hazard which could result in death, 
serious bodily injury, and/or property damage. Only 
qualified service people should service this unit. 

CAUTION: Do not operate unit without the front housing in 
place.

5.1 Technical Description

The Phoenix R150 uses a refrigeration system similar to an 

air conditioner’s to remove heat and moisture from incoming 

air and to add heat to the air that is discharged.
Hot, high pressure refrigerant gas is routed from the 

compressor to the condenser coil. The refrigerant is cooled 

and condensed by giving up its heat to the air that is about 

to be discharged from the unit. The refrigerant liquid then 

passes through a filter/drier and capillary tubing which cause 

the refrigerant pressure and temperature to drop. It next 

enters the evaporator coil where it absorbs heat from the 

incoming air and evaporates.
The evaporator operates in a flooded condition, which means 

that all the evaporator tubes contain liquid refrigerant during 

normal operation. A flooded evaporator should maintain 

constant pressure and temperature across the entire coil, 

from inlet to outlet.
The mixture of gas and liquid refrigerant enter the 

compressor after leaving the evaporator coil. The compressor 

evacuates the cool refrigerant gas from the accumulator and 

compresses it to a high pressure and temperature to repeat 

the process.

Refrigeration system

Summary of Contents for R150

Page 1: ... drying Energy Efficiency Removes 75 pints at AHAM while drawing only 5 5 amps Patented Bypass Technology Extends operating range to 110 F 150 CFM Optimized process air speeds drying and provides static pressures for ducting More Grain Depression Drier air from an LGR gets your jobs done quicker Focused Airflow Patented Focused outlet directs air downward across the wet surface Outlet Ducting 10 e...

Page 2: ...uct Options Outlet 10 Lay Flat Warranty Five years 1st year 100 of Parts and Labor 2nd 5th year 100 of Parts of sealed refrigeration system Size 30 high x 20 wide x 17 deep Weight 82 lbs Patent 7 246 503 7 281 389 7 540 166 3 Operation Place dehumidifier inside structure place condensate hose into a drain or a very large container and turn on To decrease drying times make sure all windows and door...

Page 3: ...ll continue to run causing air to flow through the evaporator coil and melt the ice when the compressor is off When the air temperature and or humidity increases the evaporator temperature will rise and the thermistor will end the defrost cycle at the temperature set point 3 6 POWER Button Press the POWER button to turn the dehumidifier on or off When starting the dehumidifier the display will sho...

Page 4: ...o that it drains into the heat exchanger 4 Use PURGE button to remove chemicals in reservoir Run PURGE until hose runs dry 5 Walk out hose to drain completely 6 Replace air filter 5 Service WARNING Servicing the Phoenix R150 with its high pressure refrigerant system and high voltage circuitry presents a health hazard which could result in death serious bodily injury and or property damage Only qua...

Page 5: ... compressor overload 5 Defective compressor 6 Defective control board Air mover does not run Compressor runs briefly but cycles on and off 1 Loose connection in blower circuit 2 Obstruction prevents impeller rotation 3 Defective air mover Unit removes some water but not as much as expected 1 Air temperature and or humidity have dropped 2 Humidity meter and or thermometer used are out of calibratio...

Page 6: ...place the pump hose wiring bolts and housing in the reverse order 6 Options Accessories 4026315 Air Filter Pleated 12 x 12 x 1 MERV 8 4025568 Air Filter Pleated 12 x 12 x 1 MERV 11 4024935 Lay Flat Duct 10 Round x 250 Roll To order contact Therma Stor LLC at 1 800 533 7533 5 3 Air Mover The motorized impeller has a PSC motor and internal thermal overload protection If defective the complete assemb...

Page 7: ...2 BLK 16 WHT 2 WHT 7 BLK 3 GRN BLU 8 BLK 4 BLK 11 YEL YEL BLU YEL YEL 10 RED 9 WHT 7 BLK GRY WHT 6 CONTROL BOARD RUN CAP FAN MOTOR PUMP SAFETY NO NC FLOAT WHT PUMP FAN LEVEL SWITCH THERMISTOR 1 LINE 2 NEUT 3 COMP RUN CAP PLUG 5 4 C R S COMPRESSOR BLK 15 BLK P N 4031273 REV C Wiring diagram 7 Wiring Diagram ...

Page 8: ... 1 4030483 9 Thermistor Probe 1 4034716 02 10 Capacitor Impeller 6 0 μF 1 4033031 03 11 Hex Bolts 1 4 20 x 1 25 6 1154012 12 Handle Bar 1 4031267 13 Handle Grip 1 4031268 14 Wheel 12 Black 2 4026851 15 Cotter Pin 2 1284404 16 Hub Cap Wheel Black 2 4027138 17 Handle Knob Lanyard 2 4033372 18 Control Board 1 4034457 19 Power Cord 1 4032297 Items listed are not shown Description Qty Part No Hose 1 4 ...

Page 9: ...The end user is responsible for normal care This warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control Limitation and Exclusions If any Phoenix R150 Dehumidifier part is repaired...

Reviews: