background image

9

www.UsePhoenix.com • [email protected]

Toll-Free 1-800-533-7533

Phoenix R150 Dehumidifier Limited Warranty

Warrantor:

Therma-Stor LLC
4201 Lien Rd.
Madison, WI 53704
Telephone: 1-800-533-7533

Who Is Covered:

 This warranty extends only to the original end-user of the Phoenix R150 

dehumidifier and may not be assigned or transferred.

Year One:

 Therma-Stor LLC warrants that, for one (1) year the Phoenix R150 dehumidifier will operate 

free from any defects in materials and workmanship, or Therma-Stor LLC will, at its option, repair or 

replace the defective part(s), free of any charge.

Year(s) Two Through Five:

 Therma-Stor LLC further warrants that for a period of five (5) years, the 

condenser, evaporator, and compressor of the Phoenix R150 dehumidifier will operate free of any 

defects in material or workmanship, or Therma-Stor LLC, at its option, will repair or replace the 

defective part(s), provided that all labor and transportation charges for the part(s) shall be borne by 

the end-user.

Year(s) One Through Seven:

 Materials and workmanship of the housing are covered.

End-User Responsibilities: 

Warranty service must be performed by a Servicer authorized by 

Therma-Stor LLC. If the end-user is unable to locate or obtain warranty service from an authorized 

Servicer, he should call Therma-Stor LLC at the above number and ask for the Therma-Stor Service 

Department, which will then arrange for covered warranty service. Warranty service will be performed 

during normal working hours.
The end-user must present proof of purchase (lease) upon request, by use of the warranty card or 

other reasonable and reliable means. The end-user is responsible for normal care. This warranty 

does not cover any defect, malfunction, etc. resulting from misuse, abuse, lack of normal care, 

corrosion, freezing, tampering, modification, unauthorized or improper repair or installation, accident, 

acts of nature or any other cause beyond Therma-Stor LLC’s reasonable control.

Limitation and Exclusions:

 If any Phoenix R150 Dehumidifier part is repaired or replaced, the new 

part shall be warranted for only the remainder of the original warranty period applicable thereto 

(but all warranty periods will be extended by the period of time, if any, that the Phoenix R150 

Dehumidifier is out of service while awaiting covered warranty service).
UPON THE EXPIRATION OF THE WRITTEN WARRANTY APPLICABLE TO THE PHOENIX R150 

DEHUMIDIFIER OR ANY PART THEREOF, ALL OTHER WARRANTIES IMPLIED BY LAW, INCLUDING 

MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL ALSO EXPIRE. ALL 

WARRANTIES MADE BY THERMA-STOR LLC ARE SET FORTH HEREIN, AND NO CLAIM MAY BE MADE 

AGAINST THERMA-STOR LLC BASED ON ANY ORAL WARRANTY. IN NO EVENT SHALL THERMA-STOR 

LLC, IN CONNECTION WITH THE SALE, INSTALLATION, USE, REPAIR OR REPLACEMENT OF ANY 

PHOENIX R150 DEHUMIDIFIER OR PART THEREOF BE LIABLE UNDER ANY LEGAL THEORY FOR 

ANY SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION WATER 

DAMAGE (THE END-USER SHOULD TAKE PRECAUTIONS AGAINST SAME), LOST PROFITS, DELAY, OR 

LOSS OF USE OR DAMAGE TO ANY REAL OR PERSONAL PROPERTY.
Some states do not allow limitations on how long an implied warranty lasts, and some do not 

allow the exclusion or limitation of incidental or consequential damages, so one or both of these 

limitations may not apply to you. 

Legal Rights:

 This warranty gives you specific legal rights, and you may also have other rights which 

vary from state to state.

Summary of Contents for R150

Page 1: ... drying Energy Efficiency Removes 75 pints at AHAM while drawing only 5 5 amps Patented Bypass Technology Extends operating range to 110 F 150 CFM Optimized process air speeds drying and provides static pressures for ducting More Grain Depression Drier air from an LGR gets your jobs done quicker Focused Airflow Patented Focused outlet directs air downward across the wet surface Outlet Ducting 10 e...

Page 2: ...uct Options Outlet 10 Lay Flat Warranty Five years 1st year 100 of Parts and Labor 2nd 5th year 100 of Parts of sealed refrigeration system Size 30 high x 20 wide x 17 deep Weight 82 lbs Patent 7 246 503 7 281 389 7 540 166 3 Operation Place dehumidifier inside structure place condensate hose into a drain or a very large container and turn on To decrease drying times make sure all windows and door...

Page 3: ...ll continue to run causing air to flow through the evaporator coil and melt the ice when the compressor is off When the air temperature and or humidity increases the evaporator temperature will rise and the thermistor will end the defrost cycle at the temperature set point 3 6 POWER Button Press the POWER button to turn the dehumidifier on or off When starting the dehumidifier the display will sho...

Page 4: ...o that it drains into the heat exchanger 4 Use PURGE button to remove chemicals in reservoir Run PURGE until hose runs dry 5 Walk out hose to drain completely 6 Replace air filter 5 Service WARNING Servicing the Phoenix R150 with its high pressure refrigerant system and high voltage circuitry presents a health hazard which could result in death serious bodily injury and or property damage Only qua...

Page 5: ... compressor overload 5 Defective compressor 6 Defective control board Air mover does not run Compressor runs briefly but cycles on and off 1 Loose connection in blower circuit 2 Obstruction prevents impeller rotation 3 Defective air mover Unit removes some water but not as much as expected 1 Air temperature and or humidity have dropped 2 Humidity meter and or thermometer used are out of calibratio...

Page 6: ...place the pump hose wiring bolts and housing in the reverse order 6 Options Accessories 4026315 Air Filter Pleated 12 x 12 x 1 MERV 8 4025568 Air Filter Pleated 12 x 12 x 1 MERV 11 4024935 Lay Flat Duct 10 Round x 250 Roll To order contact Therma Stor LLC at 1 800 533 7533 5 3 Air Mover The motorized impeller has a PSC motor and internal thermal overload protection If defective the complete assemb...

Page 7: ...2 BLK 16 WHT 2 WHT 7 BLK 3 GRN BLU 8 BLK 4 BLK 11 YEL YEL BLU YEL YEL 10 RED 9 WHT 7 BLK GRY WHT 6 CONTROL BOARD RUN CAP FAN MOTOR PUMP SAFETY NO NC FLOAT WHT PUMP FAN LEVEL SWITCH THERMISTOR 1 LINE 2 NEUT 3 COMP RUN CAP PLUG 5 4 C R S COMPRESSOR BLK 15 BLK P N 4031273 REV C Wiring diagram 7 Wiring Diagram ...

Page 8: ... 1 4030483 9 Thermistor Probe 1 4034716 02 10 Capacitor Impeller 6 0 μF 1 4033031 03 11 Hex Bolts 1 4 20 x 1 25 6 1154012 12 Handle Bar 1 4031267 13 Handle Grip 1 4031268 14 Wheel 12 Black 2 4026851 15 Cotter Pin 2 1284404 16 Hub Cap Wheel Black 2 4027138 17 Handle Knob Lanyard 2 4033372 18 Control Board 1 4034457 19 Power Cord 1 4032297 Items listed are not shown Description Qty Part No Hose 1 4 ...

Page 9: ...The end user is responsible for normal care This warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control Limitation and Exclusions If any Phoenix R150 Dehumidifier part is repaired...

Reviews: