2.10   Phoenix Controls Cables 

Cable

Type

Plenum

Rated

Function

Wire 

Gauge

Primary 

Vendor/Part #

Alternate Vendor/

Part #

Color Code

Notes

2C Round

No

24 Vac power  

18

Belden 9409

1: Red
2: Black

Must be stranded

24 Vac power

14

Belden 9411

2C Round

Yes

24 Vac power

18

Belden 82740

Windy City 
NP002360

1: Red
2: Black

Must be stranded

24 Vac power 

14

Windy City NP007960

TP

NO

FTT-10 (4,500 FT)
TP1250 (425 FT)

22

Windy City 107500
www,smartwire.com

1: White with Blue Stripe
2: Blue with White Stripe

FTT-10 (8,000 FT)

16

Windy City 109600
www,smartwire.com

TP

Yes

FTT-10 (4,500 FT)
TP1250 (425 FT)

22

Windy City 105500
S=SPOOL B=BOX

1: White with Blue Stripe
2: Blue with White Stripe

FTT-10 (8,000 FT)

16

Windy City 109500
www,smartwire.com

3C Round

No

Signal

22

Belden 8443

1: Red 
2: Black 
3: Green

Must be stranded

3C or 4C  
Round

Yes

Signal

22

Belden 88444

Windy City 004380

1: Red 
2: Black
3: Green
4: White (not used as 3C)

Must be stranded

4C Round

No

Signal

22

Belden 8444

Manhattan M13304

1: White 
2: Green
3: Black 
4: Red  

Must be stranded

5C Round

No

Signal

22

Belden 8445

Manhattan M13305

1: White
2: Brown 
3: Black 
4: Red  
5: Green

Must be stranded

8C 

No

Signal

22

Belden 9421

Manhattan M13308

1: White
2: Orange
3: Black
4: Red
5: Green
6: Yellow
7: Blue
8: Brown

No substitutes

8C 

Yes

Signal

22

Comtran 4956

1: White 
2: Orange
3: Black
4: Red
5: Green
6: Yellow
7: Blue
8: Brown 

No substitutes

3C 
MS/TP

No

Shielded

22

Belden 3106A 
(120 ohm)

1: White with Orange stripe
2: Orange with White stripe
3: Blue with White stripe   

Shielded with 
drain

3C 
MS/TP

Yes

Shielded

22

Connect-Air W223C-
2060YPC

1: Black
2: White
3: Red

Foil shield with 
drain wire

Phoenix and Phoenix Controls are trademarks of Honeywell International, Inc. 

The material in this document is for information purposes only and is subject to change without notice. Phoenix Controls assumes no responsibility for any errors 
or for consequential damages that may result from the use or misrepresentation of any of the material in this publication.

Phoenix Controls is a business of Honeywell International, Inc.

For additional information and a listing of our global offices, please visit our Web site at www.phoenixcontrols.com or call (800) 340-0007.

Summary of Contents for PCS300-x

Page 1: ...g recommendations It is recommended that the sensor s be kept at room temperature for at least 24 hours before installation to allow any condensation that may have accumulated due to low temperature d...

Page 2: ...wire through the wall and out of the 1 2 hole leaving about six inches free 6 Pull the wire through the hole in the base plate 7 Secure the base to the drywall anchors using the 6 x 1 inch mounting sc...

Page 3: ...s are possible when AC power wiring is present in the same conduit as the signal lines If you are experiencing any of these difficulties please contact your Phoenix Controls Representative Local and n...

Page 4: ...Terminal Applicable to Option Description OVR1 and OVR2 PCS300 x DOS only O Occupancy override status N O contact output 300 mA 24 Vdc SET1 and SET2 PCS300 x DOS only S Temperature setpoint 0 20 K ou...

Page 5: ...300 mA 30 Vdc SET1 and SET2 PCS300 x DOS only S Temperature setpoint 0 20 K output SEN1 and SEN2 PCS300 x and PCS300 x DOS Temperature sensor 10K 2 thermistor output EXT OVR PCS300 x DOS only D Exter...

Page 6: ...default display shows current temperature toggled every 5 seconds with space humidity When the setpoint slider is moved enough to change the setpoint by 0 5 degrees the setpoint will be displayed as...

Page 7: ...to the first closing of the DO EXT OVR grounded the unit will behave as described in Local Occupancy Override above 2 4 Optional Technicians Adjustments This section details optional adjustments a tec...

Page 8: ...isplay toggles through selections 3 Even when the temperature setpoint is not displayed the terminations SET1 and SET2 are active sending a 0 to 20 K signal out PCS300 x DOS Adjustment Parameters Para...

Page 9: ...emperature Determine that the temperature sensor s wires are connected to the correct controller input terminals and are not loose Check the wires at the sensor and controller for proper connections D...

Page 10: ...Format Default Temperature and Humidity toggled every 5 seconds Temp Setpoint only when slider moved Temp Setpoint Slide pot Cool Warm Down Up Configurable at valve UI Absolute 32 122 F 0 50 C Relativ...

Page 11: ...nction entirely on their own and are not a part of another system or piece of equipment For this reason Phoenix Controls products are exempt from the WEEE Directive Nevertheless Phoenix Controls produ...

Page 12: ...anded 4C Round No Signal 22 Belden 8444 Manhattan M13304 1 White 2 Green 3 Black 4 Red Must be stranded 5C Round No Signal 22 Belden 8445 Manhattan M13305 1 White 2 Brown 3 Black 4 Red 5 Green Must be...