21
Routing the electrical cables
When routing the cables, be sure that:
•
the cables cannot get jammed,
•
no mechanical load (such as pulling, pushing or bending) will be put on the cables, and
•
the cables cannot be damaged in any way.
Fasten all cables (especially the mains cable) to the end product using sufficient strain relief and
kink prevention methods. Be sure that the design of the end product prevents the mains cable from
coming into contact with the floor during transport.
6.2.3
Dismantling
CAUTION
Electrical components should be connected or disconnected only when the mains
power cord and the battery plug (when present) are unplugged.
Certain details may change because of technical changes.
1
Move your product into a position where it is supporting no load.
CAUTION
Be sure to carry out work on the drive in a position so that no loads are bearing on it.
Only in this way can you be sure to avoid any risks of crushing or injury.
2
Unplug the mains power plug and the battery plug (when present)!
3
If multiple drives are connected electrically, they should be disconnected from each other.
4
Disconnect the drive from the control unit or double drive.
NOTICE
Be sure to support the drive's weight while you are loosening the bolt.
5
Remove the security clips and the mounting bolt.