4.   Fitting

Included in the supply package is the 

drive control unit

 and 

depending on the order a DC 

power supply, a handset

 and up one to five 

slave drives

. The components are prewired 

and ready to plug in. 

a) 

Installation  

The 

CU155

 drive control unit can be screwed to the application at the 4 fixing points using 

suitable screws (e.g. M4x50 screws). The surface onto which the controls are mounted 

must

 be level and 

flat

. It is important in the application that no mechanical forces (e.g. 

torsional forces etc.) are brought to bear on the drive controls or casing parts. Such forces 
can bring about damage (e.g. cracks) to the casing parts. 

b) 

Electrical connection 

In the 

Operating Instructions

 to be issued by you, point out to the operator that if leads, in 

particular the 

mains

 

connection lead

, are 

driven over

 they could sustain damage. 

Mechanical loads should also be avoided.

When routing the cables make sure that they

Ÿ

cannot get entangled or trapped,

Ÿ

are not subjected to mechanical loads (i.e. do not pull, apply pressure or bend),

Ÿ

cannot get damaged in any other way.

Make sure that the cables, in particular the 

connection lead 

of the voltage supply, are 

fastened to the application with adequate 

strain relief

 and 

kink protection

 and that suitable 

constructional measures prevent the 

connection lead from trailing on the floor

 when the 

application is being 

moved

First connect the 

slave drives and controls

, as shown (see page 11). Make sure that any 

sockets not being used are sealed off with 

blind plugs

- otherwise the protection category 

is not guaranteed. Do not insert the mains plug of the 

 DC power supply until all 

DewertOkin

the components have been connected to the 

CU155

 control unit. Afterwards fit the plug pull-

out safeguard (see page 7)

.

 

Caution!

 

Only ever connect or disconnect electrical components when they are voltage-free.

44

60

129

Ø 4,2

fixing

points

7

d)     Fitting the plug pull-out protection

Fit the 

plug pull-out protection (1)

 to the 

drive control unit (2)

 by allowing it to engage 

into the 

guides (3)

. Additionally, it can be firmly connected to the drive control system using 

suitable 

screws (4)

 (ST 2.9 x 6.5; ISO7049). 

e) 

Dismantling

Operate the application to travel to the starting position and disconnect the drive system 
from the mains voltage, then the drive control unit from the DewertOkin DC power supply. 
Pull-off the 

 (1)

, take this off first and then the cables from the 

plug pull-out protection

respective sockets. Loosen the retaining screws - the drive control system can now be 

 

removed from the application.

Caution!

For your own safety!

There is a 

risk of sustaining

 injury by getting trapped if the mechanical 

connections between the fitting and the drive system are loosened.

1

2

4

3

c) 

     

Fitting the reverter-plug

In order to fit the 

reverter-plug (5)

, a 

fin

 

(6)

 must be broken off the 

plug pull-out safeguard 

(1)

 at the relevant socket. This is easy to do by hand. The 

motor cable plug

 

(7)

 is then 

inserted into the 

reverter-plug

 

(5)

 which in turn is inserted into the corresponding socket of 

the control system. The plug then sits at the front of the

 plug pull-out protection

 

(1)

.

6

1

5

1

7

 CU155 

03/2020

ID 49623 3.0

03/2020

ID 49623 3.0

Summary of Contents for DewertOkin CU155

Page 1: ...I n s t a l l a t i o n I n s t r u c t i o n s Issue 03 2020 CU155 Installation Instructions Translation of the original installation instructions 03 2020 ID 49623 3 0...

Page 2: ...upply includes an earth free electric circuit which is isolated DewertOkin from the supply voltage via double or reinforced insulation DewertOkin accepts no liability for damage caused as a result of...

Page 3: ...ourself unless you are a qualified electrical engineer or you should entrust this work to suitably qualified persons only Conformity according to EC Directives The CU155 drive control unit is supplied...

Page 4: ...page 3 or by persons who have taken part and successful completed the corresponding training programmes offered by DewertOkin In the Operating Instructions to be drawn up by yourselves it is essentia...

Page 5: ...s Length x width x height of the control system 157 x 128 5 x 44 mm Weight approx 0 3 kg Ambient conditions for operation storage and transport Transport storage temperature from 20 C to 50 C from 4 F...

Page 6: ...oads should also be avoided When routing the cables make sure that they cannot get entangled or trapped are not subjected to mechanical loads i e do not pull apply pressure or bend cannot get damaged...

Page 7: ...pull out protection respective sockets Loosen the retaining screws the drive control system can now be removed from the application Caution For your own safety There is a risk of sustaining injury by...

Page 8: ...ped with up to 10 adjustment keys The control elements are assigned as follows T1 T2 T7 T5 T6 T10 T9 T3 T4 T8 Key Function T1 Motor 1 up T2 T3 T4 T5 T6 Motor 1 down Motor 1 2 Reset up Motor 1 2 Reset...

Page 9: ...shorter intervals Regular visual checks for damage of all kinds Check the housing for cracks and fractures and the mains connection lead for signs of pinching and shearing off Also check the strain r...

Page 10: ...ung CU155 Article type designation Xxxxx Article number U0 max 38V No load voltage U max 24V Rated voltage n Max 8 00A Current consumption Duty cycle 2min ON 18 min OFF Intermittent operations 2 minut...

Page 11: ...s shown This can otherwise result in damage to the drive controls Pos Part Designation Description 1 4 slave drive e g MEGAMAT MULTITRAXX DewertOkin 5 handset e g COMFORT DewertOkin 6 DC power supply...

Page 12: ...0 minutes Contact your supplier dealer Check the lead if necessary restoring contact Drives suddenly no longer respond no movement takes place Possible Cause Remedy Problem Handset or drive system wit...

Page 13: ...eaner nor spray liquids onto it You otherwise risk damaging the equipment When cleaning take care not to damage the connection lead Do not use any solvents such as benzene alcohol or similar substance...

Page 14: ...Low Voltage Directive 2014 35 EU COMMISSION DELEGATED DIRECTIVE EU 2015 863 of 31 March 2015 amending Annex II to Directive 2011 65 EU of the European Parliament and of the Council as regards the list...

Page 15: ...15 03 2020 ID 49623 3 0...

Page 16: ...DewertOkin GmbH Weststra e 1 32278 Kirchlengern Germany Phone 49 0 5223 979 0 Fax 49 0 5223 75182 http www dewertokin de Info dewertokin de CU155 03 2020 ID 49623 3 0...