6
4. Fitting
Included in the supply package is the
drive control unit
and
depending on the order a DC
power supply, a handset
and up one to five
slave drives
. The components are prewired
and ready to plug in.
a)
Installation
The
CU155
drive control unit can be screwed to the application at the 4 fixing points using
suitable screws (e.g. M4x50 screws). The surface onto which the controls are mounted
must
be level and
flat
. It is important in the application that no mechanical forces (e.g.
torsional forces etc.) are brought to bear on the drive controls or casing parts. Such forces
can bring about damage (e.g. cracks) to the casing parts.
b)
Electrical connection
In the
Operating Instructions
to be issued by you, point out to the operator that if leads, in
particular the
mains
connection lead
, are
driven over
they could sustain damage.
Mechanical loads should also be avoided.
When routing the cables make sure that they
Ÿ
cannot get entangled or trapped,
Ÿ
are not subjected to mechanical loads (i.e. do not pull, apply pressure or bend),
Ÿ
cannot get damaged in any other way.
Make sure that the cables, in particular the
connection lead
of the voltage supply, are
fastened to the application with adequate
strain relief
and
kink protection
and that suitable
constructional measures prevent the
connection lead from trailing on the floor
when the
application is being
moved
.
First connect the
slave drives and controls
, as shown (see page 11). Make sure that any
sockets not being used are sealed off with
blind plugs
,
- otherwise the protection category
is not guaranteed. Do not insert the mains plug of the
DC power supply until all
DewertOkin
the components have been connected to the
CU155
control unit. Afterwards fit the plug pull-
out safeguard (see page 7)
.
Caution!
Only ever connect or disconnect electrical components when they are voltage-free.
44
60
129
Ø 4,2
fixing
points
7
d) Fitting the plug pull-out protection
Fit the
plug pull-out protection (1)
to the
drive control unit (2)
by allowing it to engage
into the
guides (3)
. Additionally, it can be firmly connected to the drive control system using
suitable
screws (4)
(ST 2.9 x 6.5; ISO7049).
e)
Dismantling
Operate the application to travel to the starting position and disconnect the drive system
from the mains voltage, then the drive control unit from the DewertOkin DC power supply.
Pull-off the
(1)
, take this off first and then the cables from the
plug pull-out protection
respective sockets. Loosen the retaining screws - the drive control system can now be
removed from the application.
Caution!
For your own safety!
There is a
risk of sustaining
injury by getting trapped if the mechanical
connections between the fitting and the drive system are loosened.
1
2
4
3
c)
Fitting the reverter-plug
In order to fit the
reverter-plug (5)
, a
fin
(6)
must be broken off the
plug pull-out safeguard
(1)
at the relevant socket. This is easy to do by hand. The
motor cable plug
(7)
is then
inserted into the
reverter-plug
(5)
which in turn is inserted into the corresponding socket of
the control system. The plug then sits at the front of the
plug pull-out protection
(1)
.
6
1
5
1
7
CU155
03/2020
ID 49623 3.0
03/2020
ID 49623 3.0
Summary of Contents for DewertOkin CU155