DUOMAT 9
Maintenance
79338 4.0
35
9.
Maintenance
You should only use spare parts which have been manufactured or approved by DewertOkin.
Only these parts will guarantee a sufficient level of safety.
9.1
Maintenance
Type of check
Explanation
Time interval
Check the function and
safety of the electrical sys-
tem.
A qualified electrician should carry
out this inspection. (Refer to the
"Electrical connection" section in the
"Installation" Chapter.)
Periodic inspections can
be carried out at intervals
based on the risk assess-
ment which you conduct
for your end product.
Look over the housing peri-
odically for any signs of dam-
age.
Check the housing for breaks or
cracks. The IP-class protection will
be impaired by any breakage or
cracks.
At least every six
months.
Look over the plug-in con-
nections and electrical ac-
cess points for signs of dam-
age.
Check that all electrical cables and
connections are firmly seated and
correctly positioned.
At least every six
months.
Look over the cables for any
signs of damage.
Check the connecting cables for
pinching or shearing. Also check the
strain relief and kink protections
mechanisms, in particular after any
mechanical load.
At least every six
months.
Periodic functional test of the
end switches.
Move the drive to the end positions
in order to test the end switches.
At least every six
months.
Check periodically to see if
the rechargeable battery is
ready and operational.
If you can no longer move the drive
in both directions with a fully
charged battery, then you should re-
place the battery.
At least every four
weeks.
A periodic check that the me-
chanical reset function is
functioning properly.
Check that the mechanical reset
function is functioning properly (refer
to the "Optional: Mechanical reset "
section in Chapter "Operating
notes").
If the mechanical reset function is
not triggered then the drive is bro-
ken.
At least every six
months.
Periodic visual inspections,
cleaning, and then a me-
chanical-reset functionality
test (for the Bowden cable).
Check to see if the mechanical reset
function (for the Bowden cable) is
dirty. Clean and check function
again.
At least every six
months.