Technical specifications
DUOMAT 9
18
79338 4.0
5.
Technical specifications
Mains power supply connection
100 V - 240 V AC, 50/60 Hz (refer to the ratings plate on
the drive)
Current consumption at rated load
4.0 A
– 1.5 A (depending on power connection)
Push force
Max. 6000 N, depending on version (refer to the ratings
plate on the drive)
Pushing force of the ER/SB
Max. 4500 N, depending on version (refer to the ratings
plate on the drive)
Mode of operation
1
under max. rated
load.
Intermittent duty 2 min./18 min.
Protection class
II
Noise level
≤ 65 dB(A)
Current consumption of all drives
2
Max. 5 A DC for intermittent duty 2 min / 18 min
Drive type
Double drive
Drive options
DUOMAT 9, DUOMAT 9+1, DUOMAT 9+2
Protection degree
IPX4
Stroke
87, 81, 69 mm
Length x width x height
733 mm x 191 mm x 131 mm
733 mm x 193 mm x 131 mm (ER/SB)
Axle gap distance
581 ±2 mm
Diameter of axle support
Ø 25 mm, Ø 34 mm (depending on application)
Weight
Max. 6.3 kg
Ambient conditions for operation, storage and transport
Transport / storage temperature
From -20 °C to +50 °C
From -4 °F to +122 °F
Operating temperature
From +10 °C to +40 °C
From +50 °F to +104 °F
Relative humidity
From 30% to 75%
Air pressure
From 800 hPa to 1060 hPa
Height
< 2000 m
1
Mode of operation: intermittent duty 2 min./18 min. This means that after the unit is operated with its rated
load for up to two minutes it must then be paused for 18 minutes. The system can malfunction if this pause
is not observed!
2
No more than two drives may be operated at rated load simultaneously!