7.  Information about creating your Operating Manual

The factual information contained within may be used when you are creating the end-product man-

ual. The installation instructions do not contain all information required for the safe operation of the 

end product. They only describe the assembly and operation of the CONTROL UNIT as a partially 

assembled piece of machinery. 
 

  When creating the operating instructions, remember that the installation instructions are intend-

ed for qualified specialists and are not for typical users of the end product. 

 

7.1 

General information 

  You should only connect drives, vibration motors and accessories from DewertOkin to the 

CONTROL UNIT. Only DewertOkin components have been verified to work when combined to-

gether. 

 

Delayed start-up 

Please note the following after plugging the power plug into the power outlet:

 

  There is a delay after the supply voltage is applied before the device actually turns on. Wait at 

least 2 seconds before initial commissioning. 

 

Power-on time / intermittent operations 

The CONTROL UNIT has been designed for intermittent operations. Intermittent operation is an op-

erational mode where the drive must pause after a specified maximum period of operation (power-on 

time). This protects the drive from overheating. Extreme overheating can cause a malfunction. 

  The ratings plate specifies the maximum power-on time and the required pause intervals. 

 

Avoiding electrical risks 

 

  CAUTION 

Electric shock 

Make sure that no live (current-carrying) parts of the control system and power supply can be 

touched. In particular, be sure that unused power and control unit connections are covered ade-

quately.

 

 

  CAUTION 

Risk of accident 

Please follow these operating instructions carefully. You could be injured by fire or electrical 

shock if you do not follow these assembly instructions.

 

 

 

 

Summary of Contents for Dewert Okin CU458-2

Page 1: ...CONTROL UNIT CU458 2 Installation Instructions Translation of the original installation instructions...

Page 2: ......

Page 3: ...ended to be used by the end product manufacturer They should not be given to the operator of the end product The factual information contained within may be used as a basis when creating the end produ...

Page 4: ...and intended usage 6 2 2 Selection and qualification of personnel 7 2 3 Ratings plate 8 3 Possible combinations 9 4 Description 10 4 1 Components 10 5 Technical specifications 11 6 Installation 13 6 1...

Page 5: ...llowing the guidelines during installation and connection procedures will help to minimize the risk of accident and injury and damage to the CONTROL UNIT or the end product These installation instruct...

Page 6: ...product The CONTROL UNIT should not be used in any environment where combustible or explosive gases or vapours e g anaesthesiology may be present in the proximity of open fires or other heat sources s...

Page 7: ...areful there is a risk of electrical shock Before installing make sure that you disconnect the external DewertOkin power supply for the CONTROL UNIT from the power outlet The CONTROL UNIT should not b...

Page 8: ...Model No Model number 24 29 V 6 00 A Input voltage and current consumption Duty cycle 2 min ON 18 min OFF Intermittent operations 2 minutes 18 minutes Prod Date Calendar week year 2 4GHz Radio freque...

Page 9: ...been approved by DewertOkin A tailored system consists of the combination of control unit drive vibration motor accessories and hand held remote DewertOkin has separate system instruction manuals cont...

Page 10: ...bration motors and various accessories Multiple drives e g the Del ta drive and Alpha drive and vibration motors can be connected to the CONTROL UNIT Figure 2 Connections and ports on the CONTROL UNIT...

Page 11: ...x 30 mm Weight Approx 300 g Ambient conditions for operation storage and transport Transport storage temperature From 20 C to 50 C From 4 F to 122 F Operating temperature From 10 C to 40 C From 50 F...

Page 12: ...Technical specifications CU458 2 12 93728 1 0 Figure 3 Dimensions of the CONTROL UNIT top view in mm Figure 4 Dimensions of the CONTROL UNIT side view in mm 11 132 135 30 182...

Page 13: ...Okin components can be ensured by using the proper construction methods as described below 6 2 Installation procedure Before installing and connecting the CONTROL UNIT make sure that you are observing...

Page 14: ...re 6 Use the mounting holes shown in Figure 5 located on the control unit Use screws meeting the requirements of DIN 7049 with 4 8 mm diameter and of suitable length 5 mm plus the screw in depth into...

Page 15: ...cannot be damaged in any way Fasten all cables especially the connecting cables to the end product using sufficient kink preven tion methods Be sure that the design of the end product prevents the co...

Page 16: ...e note the following after plugging the power plug into the power outlet There is a delay after the supply voltage is applied before the device actually turns on Wait at least 2 seconds before initial...

Page 17: ...dio link with the CONTROL UNIT Requirement To operate your system with a Bluetooth device e g smartphone tablet download the OKIN app from the appropriate platform and install it on your device 7 2 1...

Page 18: ...r outlet 2 Press the Reset button on the CONTROL UNIT twice in quick succession see Figure 2 page 10 The floor lighting and the pairing LED light up The CONTROL UNIT remains in pairing mode for 120 se...

Page 19: ...vibration motor or accessory is defective Please contact your supplier or sales agent Hand held remote not paired Pair the hand held remote The hand held remote batteries are empty Replace the batter...

Page 20: ...e CONTROL UNIT as needed using a dry cloth NOTICE Always disconnect the power supply plug before you start to clean Never clean the CONTROL UNIT in an automated washing system or with a high pressure...

Page 21: ...2008 98 EC Waste Framework Directive WFD as of 12 12 2008 10 2 Components in the control unit The CONTROL UNIT consists of electronic components cables and metal and plastic parts You should observe...

Page 22: ...ipment IC Warning This device complies with Industry Canada RSS 210 standard s Operation is subject to the fol lowing two conditions 1 this device may not cause interference and 2 this device must ac...

Page 23: ...e determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase...

Page 24: ...erference that may cause undesired operation of the device L metteur r cepteur exempt de licence contenu dans le pr sent appareil est conforme aux CNR d Innovation Sciences et D veloppement conomique...

Page 25: ...DewertOkin GmbH Weststrasse 1 Kirchlengern 32278 Germany Tel 49 0 5223 979 0 Fax 49 0 5223 75182 http www dewertokin de Info dewertokin de ID No 93728...

Reviews: