Shutting down the CONTROL UNIT in the event of an emergency 

In an emergency, disconnect the mains power plug from its socket in order to shut off the connect-

ed drive, the accessory, and the vibration motors. The power plug must always be accessible dur-

ing operations so that it is possible to shut down the CONTROL UNIT. 

 

Avoiding cable damage 

Be sure that your operating instructions inform the user about the possible cable risks. 
 

  CAUTION 

Risk of accident 

The cables (particularly the connecting cable) should not be run over. In order to prevent injuries 

or damage to the drive and CONTROL UNIT, no mechanical strain should be placed on the ca-

bles.

 

 
 

7.2 

Configuring the hand-held remote and app 

The hand-held remote and app can be paired automatically (see chapter 7.2.1, page 17) or manu-

ally (see chapter 7.2.2, page 18). 
In order to use the hand-held remote RF1058 or a 

Bluetooth

®

 device, establish the radio link with 

the CONTROL UNIT. 

Requirement:

 To operate your system with a 

Bluetooth

®

 device (e.g.: 

smartphone/tablet), download the "OKIN" app from the appropriate platform and install it on your 

device. 
 

7.2.1 

Automatic configuration 

  The floor lighting will flash twice to acknowledge successful completion of the process. 

 

Insert the power plug into a power outlet. 

The CONTROL UNIT remains in pairing mode for 120 seconds. The pairing mode is split as fol-

lows: 

 

A RF1058 hand-held remote can be paired in the first 60 seconds. 

 

Bluetooth

®

 device can be paired in the second 60 seconds. 

  During the RF1058 pairing phase, the floor (under-bed) LED and the paring LED on the CON-

TROL UNIT light up. 

Press the 

 + 

 buttons on the RF1058 hand-held remote simultaneously (see RF1058 

hand-held remote instructions). A successful pairing will be acknowledged. 

  The floor lighting will switch off after the pairing process for the hand-held remote RF1058 is fin-

ished. The pairing LED for pairing a 

Bluetooth

®

 device starts flashing. 

  The pairing LED switches off when the 

Bluetooth

®

 pairing process has timed out or when the 

device has connected successfully. A successful pairing will be acknowledged. 

 

Summary of Contents for Dewert Okin CU458-2

Page 1: ...CONTROL UNIT CU458 2 Installation Instructions Translation of the original installation instructions...

Page 2: ......

Page 3: ...ended to be used by the end product manufacturer They should not be given to the operator of the end product The factual information contained within may be used as a basis when creating the end produ...

Page 4: ...and intended usage 6 2 2 Selection and qualification of personnel 7 2 3 Ratings plate 8 3 Possible combinations 9 4 Description 10 4 1 Components 10 5 Technical specifications 11 6 Installation 13 6 1...

Page 5: ...llowing the guidelines during installation and connection procedures will help to minimize the risk of accident and injury and damage to the CONTROL UNIT or the end product These installation instruct...

Page 6: ...product The CONTROL UNIT should not be used in any environment where combustible or explosive gases or vapours e g anaesthesiology may be present in the proximity of open fires or other heat sources s...

Page 7: ...areful there is a risk of electrical shock Before installing make sure that you disconnect the external DewertOkin power supply for the CONTROL UNIT from the power outlet The CONTROL UNIT should not b...

Page 8: ...Model No Model number 24 29 V 6 00 A Input voltage and current consumption Duty cycle 2 min ON 18 min OFF Intermittent operations 2 minutes 18 minutes Prod Date Calendar week year 2 4GHz Radio freque...

Page 9: ...been approved by DewertOkin A tailored system consists of the combination of control unit drive vibration motor accessories and hand held remote DewertOkin has separate system instruction manuals cont...

Page 10: ...bration motors and various accessories Multiple drives e g the Del ta drive and Alpha drive and vibration motors can be connected to the CONTROL UNIT Figure 2 Connections and ports on the CONTROL UNIT...

Page 11: ...x 30 mm Weight Approx 300 g Ambient conditions for operation storage and transport Transport storage temperature From 20 C to 50 C From 4 F to 122 F Operating temperature From 10 C to 40 C From 50 F...

Page 12: ...Technical specifications CU458 2 12 93728 1 0 Figure 3 Dimensions of the CONTROL UNIT top view in mm Figure 4 Dimensions of the CONTROL UNIT side view in mm 11 132 135 30 182...

Page 13: ...Okin components can be ensured by using the proper construction methods as described below 6 2 Installation procedure Before installing and connecting the CONTROL UNIT make sure that you are observing...

Page 14: ...re 6 Use the mounting holes shown in Figure 5 located on the control unit Use screws meeting the requirements of DIN 7049 with 4 8 mm diameter and of suitable length 5 mm plus the screw in depth into...

Page 15: ...cannot be damaged in any way Fasten all cables especially the connecting cables to the end product using sufficient kink preven tion methods Be sure that the design of the end product prevents the co...

Page 16: ...e note the following after plugging the power plug into the power outlet There is a delay after the supply voltage is applied before the device actually turns on Wait at least 2 seconds before initial...

Page 17: ...dio link with the CONTROL UNIT Requirement To operate your system with a Bluetooth device e g smartphone tablet download the OKIN app from the appropriate platform and install it on your device 7 2 1...

Page 18: ...r outlet 2 Press the Reset button on the CONTROL UNIT twice in quick succession see Figure 2 page 10 The floor lighting and the pairing LED light up The CONTROL UNIT remains in pairing mode for 120 se...

Page 19: ...vibration motor or accessory is defective Please contact your supplier or sales agent Hand held remote not paired Pair the hand held remote The hand held remote batteries are empty Replace the batter...

Page 20: ...e CONTROL UNIT as needed using a dry cloth NOTICE Always disconnect the power supply plug before you start to clean Never clean the CONTROL UNIT in an automated washing system or with a high pressure...

Page 21: ...2008 98 EC Waste Framework Directive WFD as of 12 12 2008 10 2 Components in the control unit The CONTROL UNIT consists of electronic components cables and metal and plastic parts You should observe...

Page 22: ...ipment IC Warning This device complies with Industry Canada RSS 210 standard s Operation is subject to the fol lowing two conditions 1 this device may not cause interference and 2 this device must ac...

Page 23: ...e determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase...

Page 24: ...erference that may cause undesired operation of the device L metteur r cepteur exempt de licence contenu dans le pr sent appareil est conforme aux CNR d Innovation Sciences et D veloppement conomique...

Page 25: ...DewertOkin GmbH Weststrasse 1 Kirchlengern 32278 Germany Tel 49 0 5223 979 0 Fax 49 0 5223 75182 http www dewertokin de Info dewertokin de ID No 93728...

Reviews: