6
4.
Fitting
Attention!
a) Installation (see illustration
1)
drive (2) into mounting (1)
BEK bolt (3)
security clip (4)
fasten stroke pipe clevis (5)
BEK bolt (8)
security clip (9)
(7)
DEWERT control unit. Secure cable (6) to prevent it
from being pulled out
Recommendation:
release “GQR“, „ER“ versions
top and bottom end-of-travel positions
)
Push and fasten it there using and secure
with .
Now with and onto
mounting .
Now connect the drive to the
(please also refer to the Installation Instructions supplied with
the DEWERT control units).
Please bear in mind that installing mechanical
limit stops into your end product considerably
increases the safety standard.
In conjunction with the (
), it is
absolutely imperative that mechanical limit stops are installed in your
end product at the , in order
to prevent mechanical damage to the drive system.
2)
3)
Attention!
Attention!
The version of the drive system with loose nut seat a fixed
mechanical stop in the end product in order to prevent the stroke tube from being
pulled out. This could otherwise damage the drive system.
MEGAMAT 2
requires
For technical reasons or to save costs, mechanical limit stops are not always provided.
In safety-critical drives we therefore recommend using an additional safety limit switch
which in the event of a defective top limit switch protects against dangerous excess
travel and failure. The safety limit switch puts the drive permanently out of action as
soon as any overshooting of the regular limit switch takes place. The safety limit switch
is integrated directly into the drive and does not require any additional fitting. However
this can increase the fitting dimension of the drive by 23 mm.
Caution!
Only ever connect or disconnect electrical components when they are voltage-free.
MEGAMAT
2
11/2008
ID-Nr. 48148