5.3.2 5 Decimal Point (400
Ω
/4000
Ω
)
Menu <–> Selection
0.0
0.00
0.000
0.0000
Please note:
The decimal point is only visual. It influences neither
the measuring accuracy nor the actual resolution,
that means for example, shifting 2 digits left results
in a display in unit of hundreds.
After the decimal point is set up, the leading zeros
will be suppressed.
5.3.2 6 Changing the scaling scope (400
Ω
/4000
Ω
)
Menu <–> Selection
use the current characteristics curve
5.5 Monitoring parameter
21
Enter or alter scaling scope
5.4 Setting the scaling scope
18
➱
➱
5.3.3 Input range 0 ... 100 mV DC
Menu <–> Select
5.3.3.1 Decimal Point for Displayed Value
Menu <–> Selection
0.0
0.00
0.000
0.0000
Please note:
The decimal point is only visual. It influences neit-
her the measuring accuracy nor the actual resolu-
tion, that means for example, shifting 2 digits left re-
sults in a display in unit of hundreds.
After the decimal point is set up, the leading zeros
will be suppressed.
5.3.3.2 Changing the Scaling slope
Menu <–> Selection
use the current scaling slope
5.5 Monitoring parameter
21
Enter or alter scaling slope
5.4 Setting the scaling slope
18
➱
➱
press key
to accept
press key
to accept the selection
press key
to accept the selection
press key
to accept the selection
press key
to accept the selection
Page 17
5.3.4 Input range –100 ... 100 mV DC, bipolar
Menu <–> Selection
5.3.4.1 Select Decimal Point
Menu <–> Selection
0.0
0.00
0.000
0.0000
Please note:
The decimal point is only visual. It influences neit-
her the measuring accuracy nor the actual resolu-
tion, that means for example, shifting 2 digits left
results in a display in unit of hundreds.
After the decimal point is set up, the leading zeros
will be suppressed.
5.3.4.2 Changing the Range Limits
The given limits for the input range can be
entered as is, or adjusted.
Parameter Parameter
Possible range of values
Possible range of values
0 ... 100 mV
not adjustable 0.0
not adjustable 100.0
–100 ... 100 mV
–100.00 ... 100.00
–100.00 ... 100.00
If the measured signal falls below or ex-
ceeds the programmed value, then the
display alternates between
and
the measured value or between
and the the measured value.
Setting values out of the range is not pos-
sible. It is only possible to continue with
the set-up, using the
keys, when the
settings are correct.
Menu <–> Selection
Example.: –50,00
Select digit
Set digit
Select digit
Set digit
Lower Limit
When the input signal falls below the
value set here, then
will be di-
splayed
Under-range: When the input signal falls
below –135 mV, then
will be di-
splayed.
english
press key
to accept the selection
press key
to accept the selection
press key
to accept the selection