Calibration
In case of using the mode 1 or 2 it is required to set the time of output closure.
In this case alarm will set exact durations, which are necessary for number of flashes used
when indicating the alarm status.
Before calibration the correct mode (1 or 2) in the Programming menu 2 must be set.
Procedure:
1. Switch the hazard light button on – car lights are flashing.
2. Open the door, turn ignition on and press the brake pedal.
3. Long press button
III
– siren beeps once.
4. Push the button on RPS sensor and hold it at duration of 10 lights flashes.
5. After loosing the button, siren will beep twice.
6. Calibration is successfully completed. Turn the hazard light button off, turn the
ignition off and release the brake pedal.
7. Connect the light output wire (CN1-3 or 4) to the hazard light switch wire (Figure
No.1). Check the polarity of common wire CN1-2. After this connection the alarm
will control flashing of the lights.
If the calibration has been done incorrectly, siren will beep 3 times. In this case repeat the
whole procedure.
VII. VALET MODE
You can access the valet mode of the alarm system even without the remote control (in case
of a lost or damaged remote). You can enter valet mode without using a PIN code or with a
PIN code (Programming menu 1-10).
Entering valet mode without a pin code.
Armed. Opened doors will trigger the alarm will be triggered. Wait for 30 second until siren
is mute. Within 3 seconds repeat the following 3 steps:
1.
Turn the key to the “Ignition On” position. When the ignition is on, the
lights on the dashboard will be turned on. In most vehicles, this
position is located two “clicks” forward from the “Off” position.
2.
Turn the ignition off. The lights on the dashboard should be turned off.
3.
Steps 1 and 2 must be repeated for a total of three times within three
seconds. Once this has been done, the alarm will be turned off and
valet mode will be activated.
Entering valet mode with PIN code.
1. Armed.
2. By opening the door, the alarm will be triggered. Siren will chirp.
3. Within 3 sec turn the ignition on/off three times.
4. Lights will flash once.
5. Push the button on RPS as many times, as your first number is. Intervals between the
click/pushes must not be longer than 1.5 sec.
6. Lights will flash once.
7. Push the button on RPS as many times, as your second number is.
8. Lights will flash twice. Siren is off.
Valet mode is activated.
Valet mode available functions:
Button
I
(0,5s) – door lock/unlock
Buttons
I+III
(0,5s) – Valet mode
Button
IV
(0,5s) – Car status check (only armed/disarmed)
Button
III
(2x short push) – 10 sec. the remote display backlight.
Buttons
II + III
(2s) – Programming the remote menu.