![Phobos MAGICAR M881 Installation Manual Download Page 35](http://html1.mh-extra.com/html/phobos/magicar-m881/magicar-m881_installation-manual_1551036035.webp)
35
Programming menu No. 1
When the door is open and ignition is on keep buttons
I
and
II
pressed simultaneously for
2 sec.
Options
No.
Function
Button I
Button II
Button III
Button IV
1-04
Emergency code RPS
Off
On
-
-
1-06
Flashing when the doors
are open
Off
On
-
-
1-08
Flashing when the trunk
is open
Off
On
-
-
1-10
PIN code
Off
On
-
-
1-11
Start kill/IG kill
IG kill
Start kill
-
-
1-12
Dome light delay
Off
5 sec
15 sec
50 sec
1-14
CAN mode
Read only
Read and Write
Read, Write and
close windows
-
Functions description:
1-04
When on, you can enter a 4-digit emergency code to cancel the alarm and open the
car.
1-06
When on, alarm will warn of the door opened by flashing the lights.
1-08
When on, alarm will warn that the hood is open by flashing the lights.
1-10
It allows you to enter the valet mode in two ways:
- simple access – by turning ignition on/off 3 times in row
- secure access – by turning ignition on/off 3 times in row and entering a 2-digit PIN code by
the button on the back side of RPS.
1-11
In case of using the
IG kill
function, the blocking output is – active (on -250mA) when
armed, - inactive during a remote starting and disarmed; in case of using the PANIC function
when disarmed, the output will be activated after 30 sec. In case of using the S
tart kill
function,
blocking output is – active when armed and remotely started, - inactive when disarmed; in
case of using the PANIC function when disarmed, the output will be activated immediately.
1-12
It is possible to set up a delayed reaction to opened door contacts when turning on the
alarm. The function is supposed to be used with indirect closed doors scanning (from the roof
light, etc.)
1-14
This function is available with CAN BUS Magicar module. In case of using the
Read only
function, Magicar only read CAN information (open door, trunk, hood, lock/unlock with OEM
remote, etc.)
In case of using the
Read and Write
function, Magicar can also control lock/unlock,
lights and klaxon except closing windows.
In case of using the
Read, Write and close windows
, Magicar can also close windows
when armed.*
* See possible function Module CAN BUS Magicar in Table of functions depending on car
type.
Programming menu No.2
When the doors are opened and ignition is on, keep the buttons
I
and
IV
pressed for 2
sec.
Options
No.
Function
Button I
Button II
Button III
Button IV
2-01
Trunk output time
0.5 sec
2 sec
3 sec
4 sec
2-02
Door lock impulse
0.8 sec
4 sec
2 x 0.8 sec
15 sec
2-03
Door unlock impulse
0.8 sec
4 sec
2 x 0.8 sec
-
2-06
Parking lights
Normal mode Continuous mode
Pulse mode
-
2-08
AUX 1
0.5 sec
5 sec
40 sec
Latch
2-09
AUX 2
0.5 sec
5 sec
40 sec
Latch
2-11
Shock sensor on/off
during AUX output
On
Off
-
-
2-13
Arm/disarm by OEM
remote control
Enabled
Disabled
-
-