6. Important information
This PS24FHDCR complies with appropriate medical EMC standards on emissions to, and interference
from surrounding equipment. Operation is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any interference received, including interfer-
ence that may cause undesired operation.
Interference can be determined by turning the equipment off and on.
If this equipment does cause harmful interference to, or suffer from harmful interference of, surrounding
equipment, the user is encouraged to try to correct the interference by one or more of the following mea-
sures:
•
Reorient or relocate the receiving antenna or equipment.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•
Consult the dealer or an experienced technician for help.
Electromagnetic immunity
The PS24FHDCR is intended for use in the electromagnetic environment speci
fi
ed below. The customer
or the user of the PS24FHDCR should assure that it is used in such an environment.
Immunity test
IEC 60601
Test levels
Compliance level
Electromagnetic
environment –
guidance
Electrostatic discharge
(ESD)
IEC 61000-4-2
± 6kV contact
± 8kV air
± 6kV contact
± 8kV air
Floors should be wood,
concrete or ceramic tile.
If
fl
oors are covered with
synthetic material, the
relative humidity should
be at least 30%
Electrical fast
transient/burst
IEC 61000-4-4
± 2kV for power supply
lines
± 1kV for input/ output
lines
± 2kV for power supply
lines
± 1kV for input/ output
lines
Mains power quality
should be that of a typical
commercial or hospital
environment
Surge
IEC61000-4-5
± 1 kV line(s) to line(s)
± 2 kV line(s) to earth
± 1 kV line(s) to line(s)
± 2 kV line(s) to earth
Mains power quality
should be that of a typical
commercial or hospital
environment
Voltage dips, short
interruptions and voltage
variations on power
supply input lines
IEC 61000-4-11
< 5% U
T
1
(> 95% dip in
U
T
) for 0.5 cycle
40% U
T
(60% dip in U
T
)
for 5 cycles
70% U
T
(30% dip in U
T
)
for 25 cycles
< 5% U
T
(>95% dip in
U
T
) for 5s
< 5% U
T
(> 95% dip in
U
T
) for 0.5 cycle
40% U
T
(60% dip in U
T
)
for 5 cycles
70% U
T
(30% dip in U
T
)
for 25 cycles
< 5% U
T
(>95% dip in
U
T
) for 5s
Mains power quality
should by that of a typical
commercial or hospital
environment. If the user
of the PS24FHDCR
requires continued
operation during power
mains interruptions,
it is recommended
that the PS24FHDCR
be powered from an
uninterruptible power
supply or a battery.
Power frequency (50/60
Hz) magnetic
fi
eld
IEC 61000-4-8
3 A/m
Not applicable
2
Power frequency
magnetic
fi
elds should
be at levels characteristic
of a typical location in
a typical commercial or
hospital environment.
Conducted RF
3 Vrms
3 V
Portable and mobile
RF communications
1. is the a.c. mains voltage prior to application of the test level.
2. PS24FHDCR doesn’t contain susceptible components to magnetic fields. Nevertheless, the PS24FHDCR has been tested up to 30
A/m.
30
K5902096 (451920611523) PS24FHDCR 08/03/2018
Summary of Contents for PS24FHDCR
Page 1: ...User Guide 24 FHD Color LCD Monitor PS24FHDCR ...
Page 4: ...Table of contents 2 K5902096 451920611523 PS24FHDCR 08 03 2018 ...
Page 8: ...1 Welcome 6 K5902096 451920611523 PS24FHDCR 08 03 2018 ...
Page 24: ...4 Advanced operation 22 K5902096 451920611523 PS24FHDCR 08 03 2018 ...
Page 26: ...5 Cleaning your display 24 K5902096 451920611523 PS24FHDCR 08 03 2018 ...
Page 43: ......
Page 44: ......
Page 45: ......