CAN Controllers and Acceptance Filter
176
Philips Semiconductors
Preliminary User Manual
LPC2119/2129/2292/2294
ARM-based Microcontroller
Figure 37: Detailed Example of Acceptance Filter Tables and ID Index Values
FULLCAN MODE
When fullCAN mode is enabled, the Acceptance Filter itself takes care of receiving and storing messages for selected Standard
ID values on selected CAN buses, in the style of “FullCAN” controllers.
In order to set this bit and use this mode, two other conditions must be met with respect to the contents of Acceptance Filter RAM
and the pointers into it:
SFF_sa
0 d := 000 h := 0 0000 0000 b
column_lower
column_upper
0
1
2
3
22
23
24
25
SFF_GRP_sa
52 d := 034 h := 0 0011 0100 b
EFF_sa
100 d := 64 h := 0 0110 0100 b
EFF_GRP_sa 112 d := 70 h := 0 0111 0000 b
ENDofTable
128 d := 080 h := 0 1000 0000 b
lower_boundary 3
lower_boundary 41
upper_boundary
lower_boundary 42
upper_boundary
lower_boundary 3 5 upper boundary
6
ID Index #
Look-up Table RAM
88d =
84d =
52d =
00d =
04d =
44d =
48d = 30h
34h
54h
58h
00h
04h
2Ch
VPB BASE+
Address
22
1
3
23
0
2
25
24
2
4 upper boundary
26 d
34 d
35 d
100d =64h
38
38 d
92d = 5Ch
lower_boundary 3 6 upper boundary
36
68h
d
39
39 d
104d =
112d =70h
41 d
116d =74h
120d =78h
42
124d =7Ch
d