background image

THREE YEAR LIMITED WARRANTY

The Philips Controls product, when properly installed and under normal conditions of use 

(without overload, abuse or alteration), is warranted to you, the original user, for a period 

of three years form the date of original retail purchase, to be free from defects in materials 

and workmanship. If during the warranty period you believe the purchased product or any 

part thereof has such a defect, you must return the product (or part) at your cost during 

such period, with proof of purchase (or if installed by a third-party a written explanation 

of installation transaction with proof of date), to Philips Controls, 2828 Trade Center Dr. 

Ste. 130B, Carrollton, TX 75007, for repair or replacement (or to an authorized Philips 

Controls supplier which agrees in advance to handle the return and replacement by factory 

authorization). If the product or part is found by Philips Controls to have been defective in 

material or workmanship it will be repaired or replaced (as deemed necessary by Philips 

Controls), and the replacement will be returned to you free of charge. The original user is 

solely responsible for any costs associated with removal and 

re-installation of the product and shipping to Philips Controls or its authorized supplier.

PHILIPS CONTROLS LIMITS THE DURATION OF THE IMPLIED WARRANTY OF 

MERCHANTABILITY WITH RESPECT TO THE PRODUCT TO THE LIMITED 

WARRANTY PERIOD SET FORTH ABOVE, AND OTHERWISE DISCLAIMS ALL 

IMPLIED WARRANTIES WITH RESPECT TO THE PRODUCT AND ITS PARTS. 

Some states disallow certain limitations on implied warranties so you should consult your 

state law if you have a questions regarding this limitation and disclaimer. Philips Controls 

disclaims any and all liability for incidental, consequential, special or indirect damage 

arising out of any claimed breach of warranty or otherwise. However, some states do not 

allow exclusion or limitation of such damages, so this disclaimer may not apply to you.

The remedy provided in the Limited Warranty for defective products is the user’s sole and 

exclusive remedy, subject to your state law. Further, this Warranty gives the user specific 

legal rights, and the user may also have other rights which may vary from state to state.

If you believe warranty claim is warranted, you may contact your nearest authorized 

Philips Controls supplier. If one does not exist in your area, please contact Philips 

Controls Customer Service at the above address (or at 1-800-526-2731), or please visit us 

at www.lolcontrols.com.

Summary of Contents for LIGHTOLIER CONTROLS LYTESCENE ILSCLTSII

Page 1: ......

Page 2: ... a Philips Controls brand This manual is for informational use only and is subject to change without notice Lightolier Controls assumes no responsibility or liability for any claims resulting from errors or inaccuracies that may appear in this manual Version as of December 15 2008 Document 85 6355A0 LyteScene II Touch Screen Master Station User s Guide 2008 Philips Controls All Rights Reserved ...

Page 3: ...g a Scene 13 Recalling a Scene 14 Skipping the Fade Rate 14 Turning Lights Off 14 Configuring a Master 15 Naming a Master 15 Setting Global Remotes 15 Configuring IR Room 16 Setting LED Intensity 16 Naming a Scene 17 Excluding Channels From a Scene 17 Designer Scenes 18 Naming a Channel 19 Assigning Non Dim Channels 19 Setting Automatic Cycle Mode 20 Enabling Panel Remote Lock 20 Configuring Alarm...

Page 4: ...CE LYTESCENE II TOUCH SCREEN USER S GUIDE 2 Customer Service Technical and Sales assistance for Lytemode products are available worldwide Phone 1 800 526 2731 In the United States and Canada 1 214 647 7880 Worldwide ...

Page 5: ... easily programmed using the front panel buttons without removing the Master Station from the wall and without the need for a computer Lytemode Master Stations are compatible with both Lightolier Controls Insulated Gate Bipolar Transistor IGBT Dimming Cabinets as well as Silicon Controlled Rectifier SCR Dimming Panels Lytemode products are controlled by the Intelligent Lytemode System ILS protocol...

Page 6: ...enes along with individual channel adjustments for any Lytemode network device can be made on the LyteScene II Touch Screen with just a few simple commands The Touch Screen is available in two mounting configurations ILSCLTSII LyteScene II Touch Screen with integral timeclock for wall mount ILSCLTSIIRM LyteScene II Touch Screen with integral timeclock for rack mount Both models feature a Real Time...

Page 7: ...rough appropriate knock out hole and install rough in box sold separately into wall Figure 1 Step 3 Connect ILS network cable to Touch Screen ILS connector Step 4 Install Touch Screen onto rough in box using four 6 flat head screws Figure 1 Installing ILSCLTSII Wall Mount Touch Screen Rough In Box Knock Out Hole Touch Screen Assembly Wall Mount Version ILS 9 Pin Connector From ILS Network Part ILS...

Page 8: ...mounting hardware Figure 2 Installing ILSCLTSIIRM Rack Mount Touch Screen Touch Screen Unit Rack Mount Version Rack Mount Screw 4 ILS 9 Pin Connector 1 WH OR Data 2 OR Data 3 SHIELD 4 WH GN Volts 5 GN Ground 6 WH BL Volts 7 BL Ground 8 WH BR Volts 9 BR Ground PIN SIGNAL WARNING Remove power from house service before connecting any wiring or cables to the LyteScene II Touch Screen From ILS Network ...

Page 9: ...Screen saver activation times and backlight off settings can be configured using the Settings tab To set display options Step 1 At main touch screen window press Settings tab to access option controls Step 2 At Display section use drop down menus to configure screen saver activation times and backlight off settings Configure screen saver Configure backlight ...

Page 10: ... 3 Press Change Password Step 4 Enter old password if applicable and press OK Step 5 Enter new password and press OK Be sure to record and store in a safe place the new password for future reference Calibrate Screen The screen can be calibrated for more accurate recognition of touch commands To calibrate screen Step 1 At main touch screen window press Settings tab Step 2 At Hardware Setup tab pres...

Page 11: ...Settings tab To set date time Step 1 At main touch screen window press Settings tab Step 2 At Hardware Setup drop down menu select Set Clock Step 3 At Date Time Properties window make required changes Step 4 Press Apply Step 5 Save registry to flash when prompted Hardware Setup Drop Down Menu Enter Date and Time information ...

Page 12: ...Master Remote functions such as storing scenes fader levels and fade rates can all be controlled by touch screen commands Refreshing Network Display If a network device has been changed or a new one has been added it may be necessary to refresh the touch screen display To refresh At main touch screen window press Refresh tab Touch screen will poll the network and display any relevant device s Pres...

Page 13: ... Master tab Controls for the ILS Master or Remote will be displayed To select a new Master for control Step 1 At ILS Master window press Select New Unit tab Step 2 At Select Master window choose a Master from drop down menu Step 3 Press OK Selected Master will now be displayed in main window Press to access Master control screen Press to launch Select Master window Currently selected Master Choose...

Page 14: ...r Scenes E L first press arrow button to bring up 8 button icon then select desired scene by pressing appropriate Scene button Changing Lighting Levels The current lighting levels can be changed at any time using the virtual faders associated with each channel To change lighting levels Step 1 Select a Master or Remote device for control Refer to Select a Master For Control on page 11 Step 2 Using ...

Page 15: ...and fade rate into that Scene The cycling will then stop and the stored Scene button will illuminate To store a scene Step 1 Select a Master or Remote device for control Refer to Select a Master For Control on page 11 Step 2 Using virtual faders make level changes for each channel as required Step 3 At Fade Rate pop up menu select fade rate as required or leave in the default Instant setting Step ...

Page 16: ...y scene including ON and OFF can be skipped at any time by pressing the Scene button twice The lighting scene change will occur instantly To turn lights on instantly Press ON button twice Turning Lights Off Pressing the OFF button will cause the lights to fade out The OFF button will blink until the fade is complete To turn lights off in the stored fade rate Press OFF Note The OFF button cannot st...

Page 17: ...nside name field to launch keypad and enter a custom name Step 3 Press OK Name will now be displayed under the Master s icon along with its ID number Setting Global Remotes A Master Station will respond to up to 8 Global Remote Stations by specifying their IDs and Sub IDs A Global Remote Station has the ability to communicate with multiple masters To set global IDs Step 1 At ILS Master window pres...

Page 18: ... IR Room as Off Room 1 Room 2 Room 3 or Room 4 as required Step 3 Press OK Setting LED Intensity LED intensity brightness for a Master s buttons can be set from the touch screen To set LED intensity Step 1 At ILS Master window press Configure Master tab Step 2 At LED Intensity drop down menu select required intensity level Step 3 Press OK Press to launch Setup window Enter IR Room Setting Enter In...

Page 19: ...n be excluded from any Scene If a channel is excluded from a Scene its level will not change when that Scene button is pressed This will allow a single unit to control two rooms with some Scenes in one room some in the other and some in both To exclude a channel s Step 1 At ILS Master window press Configure Master tab Step 2 At Setup window press Scenes tab Step 3 At Scene section select desired S...

Page 20: ... Rates to be changed To set Scene as Designer Scene Step 1 At ILS Master window press Configure Master tab Step 2 At Setup window press Scenes tab Step 3 At Scene section select desired Scene using drop down menu Step 4 At Designer Scene section use buttons to specify Learn Lock setting for selected Scene Step 5 Press OK Press to launch Setup window Specify Learn Lock setting for selected scene Se...

Page 21: ...y channel can be configured as Non Dim Channels set as Non Dim do not fade but go directly from Off to Full This function is useful for inductive loads and conventional fluorescent ballasts To configure a channel as Non Dim Step 1 At ILS Master window press Configure Master tab Step 2 At Setup window press Channels tab Step 3 At Channel drop down menu select required channel Step 4 Use buttons to ...

Page 22: ...t Setup window press Options tab Step 3 At Options section check boxes for Auto Cycle settings Step 4 Press OK Enabling Panel Remote Lock To prevent unwanted tampering at a Master or Remote unit it is possible to lock the entire control panel including the Scene buttons When locked pressing any buttons at the device will have no effect To set panel lock Step 1 At ILS Master window press Configure ...

Page 23: ...his strip is divided into eight inputs with common and six LED outputs with drive The function of these inputs and outputs can be changed by configuring the Master Mode Functions include Cinema Cycle A remote closure causes the unit to cycle through Scenes A B C and D This closure comes from a projector and can automatically control the lights in a movie theater The ON scene is reserved for clean ...

Page 24: ...enu select required mode Step 4 Press OK Table 1 Terminal Strip Signals by Mode Pin Mode 0 Mode 1 Mode 2 Mode 3 1 LED Common LED Common Not Used 2 OFF LED OFF LED 3 D LED I LED 4 C LED H LED 5 B LED G LED 6 A LED F LED 7 ON LED E LED 8 Button Common Button Common Button Common Alarm Cycle Panel Lock Remote Lock 9 Lower 1 Lower 1 10 Raise 1 Raise 1 11 OFF Button OFF Button 12 D Button I Button 13 C...

Page 25: ...ab Step 2 At Hardware Setup drop down menu select Save Registry To Flash Step 3 Check appropriate Save Options box es Step 4 Press Apply Reset Software The LyteScene II Touch Screen software can be restarted just as any other computer application To reset software Step 1 From main touch screen window press Settings tab Step 2 At Hardware Setup drop down menu select Software Reset Application will ...

Page 26: ... II Touch Screen software version can be checked at any time To check software version Step 1 From main touch screen window press Settings tab Step 2 Press About tab Touch screen application information will be displayed Step 3 Press Close to return to normal operation Press to launch information window ...

Page 27: ...xceptions for holidays or other special events Events are displayed as icons or a list in the Real Time Clock screen From this screen events can be added modified or deleted In order for this feature to function properly your specific location will need to be configured in the Set Location window To access Real Time Clock event screen At main touch screen window press Real Time Clock tab Icon View...

Page 28: ...itude or by City and State to provide accurate sunrise sunset forecasting and compensation for daylight savings time To set location Step 1 At Real Time Clock screen press Set Location tab Step 2 At Set Location window enter Latitude and Longitude coordinates Use LookUp menu as required Step 3 Press OK Press to launch Set Location window ...

Page 29: ...f during the checking period a new one time event is added which schedules an Off event in the Shutoff period specified maximum 4 hours To add a new event Step 1 At Real Time Clock screen press New Event tab Step 2 At Modify Event window configure event as required Use Preset and ID drop down menus to specify which ILS Master Remote Scene will be triggered Step 3 If this is a one time event check ...

Page 30: ...gs window use drop down menus to specify times Press OK Step 8 At Modify Event window check box for Local override shutoff Step 9 Press OK to save event and return to icon list view Edit an Event The edit feature can be used to modify an existing event To edit an event Step 1 At Real Time Clock screen select icon or list item of event you wish to edit Step 2 Press Edit Event tab Step 3 At Modify E...

Page 31: ...TURE 29 Delete an Event Events can be deleted from the system at any time To delete an event Step 1 At Real Time Clock screen select icon or list item of event you wish to delete Step 2 Press Delete Event tab Step 3 At Remove Event window confirm delete action ...

Page 32: ...USER S GUIDE 30 Specifications Electrical Input power 10V 28VDC powered from Lytemode ILS Network Power draw 600mA Operating Temperature 0 to 50 C Dimensions Station 188mm x 139mm x 39 1mm 7 4 x 5 4 x 1 54 Front Bezel 204mm x 155mm 8 03 x 6 1 ...

Page 33: ...LYTESCENE II TOUCH SCREEN USER S GUIDE SPECIFICATIONS 31 Notes ...

Page 34: ...SPECIFICATIONS LYTESCENE II TOUCH SCREEN USER S GUIDE 32 Notes ...

Page 35: ...with removal and re installation of the product and shipping to Philips Controls or its authorized supplier PHILIPS CONTROLS LIMITS THE DURATION OF THE IMPLIED WARRANTY OF MERCHANTABILITY WITH RESPECT TO THE PRODUCT TO THE LIMITED WARRANTY PERIOD SET FORTH ABOVE AND OTHERWISE DISCLAIMS ALL IMPLIED WARRANTIES WITH RESPECT TO THE PRODUCT AND ITS PARTS Some states disallow certain limitations on impl...

Page 36: ......

Reviews: