INSTALLATION INSTRUCTION 94 DP 6000 DIGITAL PAGING SYSTEM
May 1999. Page 9
(S) Not Used
(T) Location detection/ System ID
Bit 3:
Location detection enable/disable (1 = enable, 0 = disabled)
Bit 2:
Location transmission mode. Location transmission from the mobile to the central control desk can be set
to take place directly after the mobile has received a new location, or only when the mobile transmits a
check-in call to the control desk. The reason for this programmable option is to provide the installer with the
possibility to avoid too many uncontrolled location calls in very busy systems. In systems using many
mobiles and/or location transmitters it is advisable to set the transmission of locations when the mobile
transmits a check-in call.
(1 = direct transmit, 0 = only with check-in calls)
Bit 1:
System ID (range HEX 0 - HEX 3) The System identity is transmitted with the ‘mode word’ in the DP6000
code to separate two neighbouring systems which are operated on the same frequency. This feature can
only be used in future systems when this function has also been implememted in the central desk. At
present the system ID digit should be set to ‘0’.
Bit 0:
System ID (range HEX 0 - HEX 3) (see Bit 1).
(U) Location digit
Enter location digit (range 0 - F (Hex)) (refer to Chapter 3.2 for a description).
4.3.2 OPCODES 2
(P) Turn on time No-move/Not-vertical alarm
Opcode digit 2(P) sets the turn on time of the No-move/Not-vertical pre-alarm in steps of 5 seconds. The mobile
should detect the No-move / Not-vertical status during the time set before it enters in to the pre-alarm status, range
0 - 75 seconds in steps of 5 seconds. Enter digits (Hex) 0 - F.
(Q) Pre-alarm time No-move/Not-vertical alarm
Opcode digit 2(Q) sets the pre-alarm time of the No-move/Not-vertical alarm in steps of 5 seconds. The mobile
should go through a prealarm status before the real alarm is transmitted to the central control unit , range 0 - 75 sec-
onds in steps of 5 seconds. Enter digits (Hex) 0 - F.
(R) Pre-alarm time Tear-out alarm
Opcode digit 2(R) sets the time a prealarm status should occur before a real alarm is transmitted to the central con-
trol, range 0 - 75 seconds in steps of 5 seconds. Enter digits (Hex) 0 - F.
(S) Options mobile mode
Bit 3:
GS procedure enable/disable (1 = enabled, 0 = disabled)
Bit 2:
No-move coupled with Not-vertical alarm: If enabled, only a No-move alarm is generated if a No-move and
a Not-vertical alarm situation is present (1 = coupled, 0 = not coupled)
Bit 1:
Not used
Bit 0:
Not used
(T) Alarm settings
Bit 3:
No-move alarm enable/disable (1 = enabled, 0 = disabled)
Bit 2:
Not-vertical alarm enable/disable (1 = enabled, 0 = disabled)
Bit 1:
Tear out enable/disable (1 = enabled, 0 = disabled)
Bit 0:
Not used
(U) Silent settings
Bit 3:
Manual alarm silent: (1 = silent, 0 = with audible bleep signal). Manual alarm with audible bleep signal to
enable rescuers to locate the individual at risk.
Bit 2:
Tear-out alarm silent (1 = silent)
Bit 1:
Not used
Bit 0:
Not used