Philips Hadco ZoneScape 1-A Documentation Download Page 25

   

 

 

 

 

ZoneScape 1-A  module documentation

.

 

 

 

 

      Proposal 

Page 

25 of 28

 

 

Ridgid conduit and connection for hard wire installation 

 

 

1. Mount the ZoneScape enclosure to a solid surface, utilizing the keyhole slot in the 
mounting bracket. 
THE ZONESCAPE MUST BE MOUNTED AT LEAST ONE FOOT ABOVE GROUND LEVEL. 
 
2. Before any connections, make sure the transformer is not plugged into an 
electrical outlet and that the power switch is in the OFF position. 
 
3. Attach waterproof connectors and conduit using the 7/8” knockouts located on 
the bottom of the enclosure. 

(All connections to be waterproof. May use waterproof sealant or silicone) 

 
4. Strip approximately 3/8” to 1/2” of the insulation o of each low voltage wire. 
5. Push the bare wires under the terminal screws on the terminal blocks and tighten 
the screws securely. 

Summary of Contents for Hadco ZoneScape 1-A

Page 1: ...ZoneScape 1 A module documentation Proposal Page 1 of 28 ZoneScape 1 A module documentation All specifications are subject to change ...

Page 2: ...schedule 10 Configuring Weekly Repeats schedule 11 Controlling the Lights Directly from the App 12 Pairing two or more ZoneScape units together 12 Example scenario two ZoneScape units paired to work together 12 Connecting ZoneScape to WiFi Router 15 Configuring ZoneScape for wired connection to a Wireless LAN Router 16 ZoneScape Customizations 21 Naming custom Zones defining button names 21 Naming...

Page 3: ...Schedule Types GB 1 14 25 8 2016 Formatting Layout GB 1 15 2 9 2016 Connecting ZoneScape to a WiFi router GB BC Overview The ZoneScape module is a programmable home automation module that provides four relay outputs for connecting light groups zones The user will be able to control independently four light groups zones per unit Furthermore the user can setup Schedules for every zone by connecting ...

Page 4: ... configured to serve IPv4 addresses via DHCP Once a device Smartphone connect to the unit via Wi Fi the unit assigns an IP address to the connected client via DHCP Every ZoneScape unit comes preconfigured with the following IP PORT settings IP 192 168 16 254 PORT 8080 The above network parameters are needed for the ZoneScape app to communicate with the ZoneScape hardware The above defaults can be ...

Page 5: ...e These settings by default are 57600 8 n 1 There are cases where after factory reset the serial settings are reset to 115200 8 n 1 and this can be seen on the module WEB configuration page 192 168 16 254 If the user encounters a 115200 8 n 1 setting after a factory reset these values need to be set to 57600 8 n 1 in the module s web configuration page as shown on the screenshot below ...

Page 6: ...peat every day Start time and End time 1x Weekly repeats Schedule Specify repeats on MON TUE WED THU FRI SAT SUN Start time and End time The table below show how many schedules can be configured in one ZoneScape unit Schedule Type Zone 1 Zone 2 Zone 3 Zone 4 Specific Day Schedule Daily repeat Schedule Weekly repeat Schedule All the above can run simultaneously and in total every ZoneScape unit can...

Page 7: ...ent Date and Time as well as the current Day of the Week and those data will be recorded and stored into the ZoneScape unit non volatile memory and the time date settings will be set to the on board Real time clock of the ZoneScape unit The above process is executed every time the user connects and starts the ZoneScape app The Time and Date taken from the user s Smartphone is considered to be the ...

Page 8: ...fic Weekdays e g MON TUE WED All of the above schedules are configured in the module via the ZoneScape App for Android and or IOS The App allows configuring of schedules via the Schedule tab Once the user tap on the Schedule tab he will be able to configure a schedule for any of the Zones Relays The procedure for configuring a Schedule for a Light Zone relay starts with the selection of the target...

Page 9: ...in order to send and apply the schedule to the ZoneScape board the user needs to tap on the OK button The application will try to establish a connection with the target ZoneScape board and once established the configured schedule will be sent and applied to the target ZoneScape board Once the user taps on the OK button a new progress dialog pops up informing the user that the settings are being se...

Page 10: ...er to send and apply the schedule to the ZoneScape board the user needs to tap on the OK button The application will try to establish a connection with the target ZoneScape board and once established the configured schedule will be sent and applied to the target ZoneScape board Once the user taps on the OK button a new progress dialog pops up informing the user that the settings are being sent to ...

Page 11: ...he schedule triggered Then in order to send and apply the schedule to the ZoneScape board the user needs to tap on the OK button The application will try to establish a connection with the target ZoneScape board and once established the configured schedule will be sent and applied to the target ZoneScape board Once the user taps on the OK button a new progress dialog pops up informing the user tha...

Page 12: ... module allows for pairing two or more units together The process involves accessing the ZoneScape unit web configuration interface and setting IP addresses net mask and ports in the respective configuration web pages The maximum number of Paired Connected ZoneScape units in one subnet is 255 Example scenario two ZoneScape units paired to work together By default the units are shipped in WiFi Acce...

Page 13: ... FI using the WI FI credentials used with Unit 1 The SSID and the KEY By default the credentials are SSID ZoneScape_xxxx where xxxx is a unique number that identifies the ZoneScape unit KEY 12345678 the default WiFi password Once the above procedure is completed then we can enter the Unit 2 ZoneScape_7899 IP parameters in the ZoneScape Application settings tab and we will have access to both of th...

Page 14: ...ape in this field or click scan and select ZoneScape from the scan results list 3 Password You need to enter the ZoneScape unit one key in this field 4 IP Type Choose STATIC from the drop down selector 5 IP Address You need to enter an IP different to 192 168 16 254 In the example below the IP 192 168 16 253 is selected 6 Subnet Mask Enter 255 255 255 0 7 Default Gateway 192 168 16 254 8 Primary D...

Page 15: ...d hit scan select the customer s wifi name and press apply Encrypt type remains wpa2 aes Change the password to the customer s wifi password Change ip type to static this will open up more settings Change ip address to first 3 sections of gateway then 200 xxx xx x 200 With our example it would be 192 168 1 200 Write down save for use in step 3 Subnet mask remains 255 255 255 0 Default gateway to x...

Page 16: ... to all the units configured in the network The Benefit of using a Wireless router is that the router can be connected to the internet allowing the user to browse the internet and at the same time control and setup schedules for the ZoneScape modules configured in that network Prerequisites RJ45 Ethernet cables from each ZoneScape unit to the Wireless WiFi Router A Standard 802 11 b g n ac router ...

Page 17: ...lease follow the steps from 1 11 and make sure that you set ZoneScape in the same network as the WiFi 802 11 router Below is a example showing a configuration of ZoneScape in the 192 168 1 network and a wired connection to a TP LINK wireless router Net Mode Default By default the ZoneScape WEB configuration interface can be accessed by visiting http 192 168 16 254 and entering the default credenti...

Page 18: ...ds the user needs to select Operation mode from the list of available options as shown in the screenshot below The user needs to select Bridge mode and click on the Apply Button and wait for around 20 seconds for the module to save settings and reboot Once done the user needs to reconnect to the ZoneScape unit and access once again the web configuration page http 192 168 16 254 home asp From the w...

Page 19: ...s and reboot After configuring the target units the user has to physically connect the units via RJ45 Ethernet cable to the Wireless LAN Router in the system and also set the unit s IP parameters and ports in the ZoneScape App Depending on the router the user may need to configure its LAN settings Below is a sample configuration for a TP LINK Wireless 802 11 b g n router ...

Page 20: ...ion parameters and set the LAN settings as follows IP Address 192 168 1 2 Network Mask 255 255 255 0 Then the user should configure a DHCP Server on the wireless interface to serve IP addresses in the same network as the LAN interfaces so that when connecting via a Smartphone with Android or iOS the units are reachable ...

Page 21: ...s a possibility to edit and add custom zone naming for every single controller configured in the ZoneScape application Furthermore the application provides the possibility to change the name of every controller configured in the system allowing the user to add customized references for the target areas zones to be controlled Naming custom Zones defining button names By default the ZoneScape applic...

Page 22: ...s After that a textbox appears and provides the user to edit and save the Zone name button name The above option is available for every single ZoneScape controller unit configured in the ZoneScape application The image below shows a screenshot showing the edit text textbox that gives the ability to change zone names After entering the Zone name button name the user taps on Done and the entered val...

Page 23: ... controller configured in the system The controller name is displayed in ZoneScape Light Switch tab in the top left corner see the image below It gives the user a reference for the target controller to be controlled ZoneScape app screenshot showing where unit names are displayed In order to edit the unit name the user needs to tap on the Settings tab and select the relevant controller from the lis...

Page 24: ...the module next to the door lock The All On and All Off buttons are push buttons With these buttons the user can turn ON and OFF all of the four zone Relays simultaneously for testing After pushing the All On pushbutton all the Zone Relays will be turned on and respectively if there are any lights wired to the ZoneScape outputs the lights will lit When the All Off pushbutton is pushed all the zone...

Page 25: ...e any connections make sure the transformer is not plugged into an electrical outlet and that the power switch is in the OFF position 3 Attach waterproof connectors and conduit using the 7 8 knockouts located on the bottom of the enclosure All connections to be waterproof May use waterproof sealant or silicone 4 Strip approximately 3 8 to 1 2 of the insulation o of each low voltage wire 5 Push the...

Page 26: ...e Wiring Diagram ZoneScape has one low voltage AC power input refer to the module specifications sheet for absolute maximum ratings for connecting to a standard low voltage garden lighting transformer Every unit also have four outputs which provide power for every single relay Zone The outputs are named Zone 1 2 3 and 4 The ZoneScape input voltage as per the specifications sheet is 15 5V AC Maximu...

Page 27: ...n try to access ZoneScape and connect via WiFi to the module and use the default key 12345678 After Applying factory defaults please make sure that you have edited and applied the settings written on page 5 of this Manual I am connected to ZoneScape I can t control the ZoneScape Zones from the App I can t set schedules Check whether you have set the ZoneScape IP address in the ZoneScape APP Settin...

Page 28: ...t you have edited and applied the settings written on page 5 of this Manual I have reinstalled the ZoneScape App and I cannot see the schedules that I have previously configured The current implementation saves the schedules both in ZoneScape App database and also saves the schedule in the Actual unit however there is no read schedules feature implemented currently that will read the existing sche...

Reviews: