eW Burst Powercore Product Guide
21
• Disengage the leader cable from the fixture’s canopy base.
2. Mount junction boxes in accordance with the lighting design plan.
3. Position each eW Burst Powercore Architectural fixture in its designated
mounting location. Make sure the mounting surface is flat, suitable for the
mounting hardware, and clear of debris and other obstructions.
4. Use four suitable mounting screws to secure each eW Burst Powercore
Architectural fixture to the mounting location.
5. If installing fixtures in a series, pull 3-conductor copper wire between the junction
boxes. If installing fixtures in parallel, pull 3-conductor copper wire from line
power to a common junction box, and from the common junction box to each
fixture’s junction box.
We recommend the use of 12 AWG (2.05 mm), stranded 3-conductor copper
wire.
6. Use wire nuts to connect line, neutral, and ground, and tuck wire connections
into the junction box.
7. Secure all junction box covers. If installing in a damp or wet location, seal all
junction boxes with contractor-grade RTV silicone sealant. Use gaskets, clamps,
and other parts and fittings required to comply with local outdoor wiring codes.
8. If installing in parallel, connect the wires from each fixture to the lead wire from
the line power source in the common junction box.
9. Connect the wire from the first fixture in the series to the line power source if
installing in series, or from the common junction box to the line power source if
installing in parallel.
RTV Silicone
RTV Silicone
UL / cUL
UL / cUL
L
N
CE / PSE
CE / PSE
L
N
UL / cUL
CE / PSE
L
N
L
N
L N
L N
UL / cUL
CE / PSE
L N
L N
UL / cUL
UL / cUL
L
N
CE / PSE
CE / PSE
L
N
UL / cUL
CE / PSE
L
N
L
N
L N
L N
UL / cUL
CE / PSE
L N
L N
Fixture cable dimensions
.38 in
(9.6 mm)
18 AWG
.04 in (1 mm)
E
Ensure that all junction boxes are
suitable for the environment and that all
wiring between junction boxes complies with
local codes.