eW Burst Powercore Product Guide
14
4.5 in
(114 mm)
5.625 in
(143 mm)
9.85 in
(250 mm)
7 in
(178 mm)
5/16 in hex
(8 mm hex)
4.5 in
(114 mm)
8.06 in
(205 mm)
7 in
(178 mm)
eW Burst Compact Powercore Specifications
Due to continuous improvements and innovations, specifications may change without notice.
Item
Specification
Details
Output
Beam Angle
8° primary optic
14° / 23° / 41° spread lenses
10° x 41° asymmetric spread lens
CRI
83 (2700 K) 81 (4000 K)
Lumen Maintenance
‡
90,000 hours L70 @ 25° C 50,000 hours L70
@ 50° C
120,000 hours L50 @ 25° C 90,000 hours L50
@ 50° C
Electrical
Input Voltage
100 – 277 VAC, auto-switching, 50 / 60 Hz
Power Consumption
15 W maximum at full output, steady state
Power Factor
.995 @ 120 VAC (2700 K) .994 @ 120 VAC (4000 K)
Control
Dimming
Compatible with many commercially available ELV, trailing edge,
or reverse-phase control dimmers
§
Physical
Dimensions
(Height x Width x Depth)
9.85 x 4.5 x 7.0 in (250 x 114 x 178 mm) Architectural
8.06 x 4.5 x 7.0 in (205 x 114 x 178 mm) Landscape
Weight
8.7 lb (3.9 kg) Architectural 4.4 lb (2.0 kg) Landscape
Housing
Die-cast aluminium, powder-coated finish
Lens
Tempered glass
Fixture Connections
6 ft (1.8 m) unified power / data cable with flying leads Architectural
6 in (152 mm) flying leads Landscape
Temperature Ranges
-40° – 122° F (-40° – 50° C) Operating
-4° – 122° F (-20° – 50° C) Startup
-40° – 176° F (-40° – 80° C) Storage
Vibration Resistance
ANSI C136.31 (Architectural only)
Humidity
0 – 95%, non-condensing
Certification
and Safety
Certification
UL / cUL, FCC Class A, CE
Environment
Dry / Damp / Wet Location, IP66
Item
Color Temp.*
8° primary
14°
23°
41°
10° x 41°
Lumens
†
2700 K
624
543
540
520
557
4000 K
812
685
674
646
695
Efficacy (lm / W)
2700 K
41.9
36.4
36.2
34.8
37.4
4000 K
53.8
45.7
44.6
42.8
46.3
eW Burst Compact
Powercore Landscape
eW Burst Compact
Powercore Architectural
* Color temperatures conform to nominal CCTs as defined in ANSI Chromaticity
Standard C78.377A.
† Lumen measurement complies with IES LM-79-08 testing procedures
‡ L70 = 70% maintenance of lumen output (when light output drops below 70% of initial output).
L50 = 50% maintenance of lumen output (when light output drops below 50% of initial output).
Ambient temperatures specified. Based on measurements that comply with IES LM-80-08 testing
procedures. Refer to www.colorkinetics.com/support/appnotes/lm-80-08.pdf for more information.
§
Refer to www.colorkinetics.com/support/appnotes/ for specific details