background image

eW Burst Powercore    Product Guide

18

Installation

eW Burst Powercore LED fixtures offer a wash of high-intensity warm or neutral 

white light for spotlighting, site, and accent lighting. Powercore delivers line voltage 

directly to the fixture and eases installation by eliminating the need for external 

power supplies or special wiring. 

Owner / User Responsibilities 

It is the responsibility of the contractor, installer, purchaser, owner, and user to 

install, maintain, and operate eW Burst Powercore fixtures in such a manner as to 

comply with all applicable codes, state and local laws, ordinances, and regulations. 

Consult with the appropriate electrical inspector to ensure compliance.

Installing in Damp or Wet Locations

When installing in damp or wet locations, it is good practice to seal all fixtures and 

junction boxes with electronics-grade RTV silicone sealant to ensure that moisture 

cannot enter or accumulate in any wiring compartments, cables, or other electrical 

parts. You must use suitable outdoor-rated junction boxes when installing in wet or 

damp locations. Additionally, you must use gaskets, clamps, and other parts required 

for installation to comply with all applicable local and national codes

Prepare for the Installation

1.  Carefully inspect the box containing eW Burst Powercore and the contents for 

any damage that may have occurred in transit.

2.  Ensure that all additional parts and tools are available, including:

eW Burst Powercore Architectural Installations

•  The provided stainless steel screws for outdoor installations
•  The provided junction box gasket for outdoor installations
•  Unless surface-mounting, one 4 in (102 mm) round US electrical junction box 

per fixture, rated for your application, with 3.5 in (89 mm) center-to-center 

screw holes for attaching the fixture’s base. (Refer to the manufacturer’s 

literature for additional items required for mounting or sealing.)

•  A 5/16 in or 8 mm hex wrench for fixture tilting and locking
•  A 1/8 in or 3 mm hex wrench for fixture swiveling and locking

eW Burst Powercore Landscape Installations

•  The provided locking nut
•  One electrical junction box or mounting accessory per fixture, rated for your 

application. (Refer to the junction box or accessory manufacturer’s literature 

for specific information on mounting or sealing.)

•  A 6 mm hex wrench for fixture tilting and locking
•  A 33 mm wrench for locking the fixture in place

All Installations

 •  A sufficient length 3-conductor wire. We recommend 12 AWG (2.05 mm) 

stranded copper wire.

•  Conduit as required
•  Electronics-grade room temperature vulcanizing (RTV) silicone sealant as 

required

•  A 5/32 in hex wrench for installing accessories

E

 Refer to the eW Burst Powercore 

Installation Instructions for specific warning 

and caution statements.

Included in the box

eW Burst Powercore Architectural

eW Burst Powercore Architectural fixture
(4) 10-24 stainless steel screws for outdoor installation
Junction box gasket
Installation Instructions

eW Burst Powercore Landscape

eW Burst Powercore Landscape fixture
Locking nut
Installation Instructions

Summary of Contents for eW Burst Powercore

Page 1: ...SERIOUSLY F P O eW Burst Powercore High output exterior white spotlight for accent and site lighting ...

Page 2: ...lighting applications Native 8 beam angle offers extended light projection Available glare shields block spill light while honeycomb louvers limit the spread of light for a more focused and intense beam Versatile light positioning eW Burst Powercore fixtures can tilt through a full 180 eW Burst Powercore Architectural fixtures can also rotate through a full 360 for precise aiming Locking screws ac...

Page 3: ...Summary Zone Lumens Lamp Luminaire 0 30 1 095 8 93 8 93 8 0 40 1 135 7 97 3 97 3 0 60 1 167 0 99 9 99 9 0 90 1 167 8 100 100 90 180 0 0 0 0 180 1 167 8 100 100 Efficiency Total 100 Zonal Lumen Cd 0 6 500 13 000 19 500 26 000 32 500 39 000 VA 0º 10º 20º 30º 40º 90º 80º 70º 60º 50º 0º H 90º H 196 ft 59 7 m 1 fc maximum distance eW Burst Powercore 2700 K 8 primary optic Lumens 1168 Efficacy 39 9 lm W...

Page 4: ...00 99 98 99 98 96 98 96 95 97 95 94 96 94 92 95 93 91 94 92 91 93 91 90 92 90 89 0 1 00 98 97 95 94 93 92 91 90 89 88 Coefficients Of Utilization Zonal Cavity Method Zonal Lumen Summary Zone Lumens Lamp Luminaire 0 30 1 372 7 93 1 93 1 0 40 1 428 4 96 9 96 9 0 60 1 470 4 99 7 99 7 60 90 4 4 0 3 0 3 0 90 1 474 8 100 100 90 180 0 0 0 0 180 1 474 8 100 100 Efficiency Total 100 Zonal Lumen 217 ft 66 1...

Page 5: ...thod Zonal Lumen Summary Zone Lumens Lamp Luminaire 0 30 948 9 92 9 92 9 0 40 990 1 96 9 96 9 0 60 1 020 3 99 9 99 9 60 90 1 2 0 1 0 1 0 90 1 021 6 100 100 90 180 0 0 0 0 180 1 021 6 100 100 Efficiency Total 100 Zonal Lumen Cd 0 2 167 4 333 6 500 8 667 10 833 13 000 VA 0º 10º 20º 30º 40º 90º 80º 70º 60º 50º 0º H 90º H 109 5 ft 33 4 m 1 fc maximum distance eW Burst Powercore 2700 K 14 spread lens L...

Page 6: ...9 86 85 87 85 83 0 1 00 98 95 93 91 90 88 87 85 84 83 Coefficients Of Utilization Zonal Cavity Method Zonal Lumen Summary Zone Lumens Lamp Luminaire 0 30 1 191 6 93 1 93 1 0 40 1 243 5 97 2 97 2 0 60 1 278 5 99 9 99 9 60 90 1 2 0 1 0 1 0 90 1 279 6 100 100 90 180 0 0 0 0 180 1 279 6 100 100 Efficiency Total 100 Zonal Lumen 122 5 ft 37 3 m 1 fc maximum distance eW Burst Powercore 4000 K 14 spread l...

Page 7: ...l Lumen Summary Zone Lumens Lamp Luminaire 0 30 914 9 91 1 91 1 0 40 963 9 96 96 0 60 1 001 0 99 7 99 7 60 90 3 3 0 3 0 3 0 90 1 004 3 100 100 90 180 0 0 0 0 180 1 004 3 100 100 Efficiency Total 100 Zonal Lumen Cd 0 750 1 500 2 250 3 000 3 750 4 500 VA 0º 10º 20º 30º 40º 90º 80º 70º 60º 50º 0º H 90º H 66 7 ft 20 3 m 1 fc maximum distance eW Burst Powercore 2700 K 23 spread lens Lumens 1004 Efficac...

Page 8: ...80 78 75 73 71 Coefficients Of Utilization Zonal Cavity Method Zonal Lumen Summary Zone Lumens Lamp Luminaire 0 30 1 149 7 91 3 91 3 0 40 1 210 5 96 2 96 2 0 60 1 255 3 99 7 99 7 60 90 3 5 0 3 0 3 0 90 1 258 7 100 100 90 180 0 0 0 0 180 1 258 7 100 100 Efficiency Total 100 Zonal Lumen 74 7 ft 22 8 m 1 fc maximum distance eW Burst Powercore 4000 K 23 spread lens Lumens 1259 Efficacy 41 9 lm W eW Bu...

Page 9: ...thod Zonal Lumen Summary Zone Lumens Lamp Luminaire 0 30 795 3 80 3 80 3 0 40 917 4 92 6 92 6 0 60 982 7 99 2 99 2 60 90 8 1 0 8 0 8 0 90 990 8 100 100 90 180 0 0 0 0 180 990 8 100 100 Efficiency Total 100 Zonal Lumen Cd 0 350 700 1 050 1 400 1 750 2 100 VA 0º 10º 20º 30º 40º 90º 80º 70º 60º 50º 0º H 90º H 45 ft 13 7 m 1 fc maximum distance eW Burst Powercore 2700 K 41 spread lens Lumens 991 Effic...

Page 10: ... 59 0 1 00 94 89 84 79 75 71 67 64 61 58 Coefficients Of Utilization Zonal Cavity Method Zonal Lumen Summary Zone Lumens Lamp Luminaire 0 30 996 9 80 4 80 4 0 40 1 149 6 92 7 92 7 0 60 1 230 4 99 2 99 2 60 90 9 8 0 8 0 8 0 90 1 240 2 100 100 90 180 0 0 0 0 180 1 240 2 100 100 Efficiency Total 100 Zonal Lumen 50 3 ft 15 3 m 1 fc maximum distance eW Burst Powercore 4000 K 41 spread lens Lumens 1240 ...

Page 11: ...en Summary Zone Lumens Lamp Luminaire 0 30 910 4 87 87 0 40 992 4 94 9 94 9 0 60 1 041 2 99 5 99 5 60 90 4 8 0 5 0 5 0 90 1 046 0 100 100 90 180 0 0 0 0 180 1 046 0 100 100 Efficiency Total 100 Zonal Lumen Cd 0 1 233 2 467 3 700 4 933 6 167 7 400 VA 0º 10º 20º 30º 40º 90º 80º 70º 60º 50º 0º H 90º H 85 5 ft 26 1 m 1 fc maximum distance eW Burst Powercore 2700 K 10 x 41 spread lens Lumens 1046 Effic...

Page 12: ...ummary Zone Lumens Lamp Luminaire 0 30 1 151 3 87 5 87 5 0 40 1 253 0 95 2 95 2 0 60 1 311 3 99 6 99 6 60 90 5 2 0 4 0 4 0 90 1 316 5 100 100 90 180 0 0 0 0 180 1 316 5 100 100 Efficiency Total 100 Zonal Lumen Cd 0 1 533 3 067 4 600 6 133 7 667 9 200 VA 0º 10º 20º 30º 40º 90º 80º 70º 60º 50º 0º H 90º H 96 ft 29 3 m 1 fc maximum distance eW Burst Powercore 4000 K 10 x 41 spread lens Lumens 1317 Eff...

Page 13: ...hours L70 25 C 45 000 hours L70 50 C 120 000 hours L50 25 C 70 000 hours L50 50 C Electrical Input Voltage 100 277 VAC auto switching 50 60 Hz Power Consumption 30 W maximum at full output steady state Power Factor 978 120 V 2700 K 975 120 V 4000 K Control Dimming Compatible with many commercially available ELV trailing edge or reverse phase control dimmers Physical Dimensions Height x Width x Dep...

Page 14: ...sh Lens Tempered glass Fixture Connections 6 ft 1 8 m unified power data cable with flying leads Architectural 6 in 152 mm flying leads Landscape Temperature Ranges 40 122 F 40 50 C Operating 4 122 F 20 50 C Startup 40 176 F 40 80 C Storage Vibration Resistance ANSI C136 31 Architectural only Humidity 0 95 non condensing Certification and Safety Certification UL cUL FCC Class A CE Environment Dry ...

Page 15: ...Gray 523 000036 00 910503700694 Black 523 000036 08 910503701793 White 523 000036 16 910503701802 Compact Gray 523 000059 00 910503701661 Black 523 000059 08 910503701924 White 523 000059 16 910503701932 4000 K Standard Gray 523 000036 01 910503700695 Black 523 000036 09 910503701794 White 523 000036 17 910503701803 Compact Gray 523 000059 01 910503701662 Black 523 000059 09 910503701925 White 523...

Page 16: ...036 12 910503701797 White 523 000036 20 910503701806 Compact Gray 523 000059 04 910503701665 Black 523 000059 12 910503701928 White 523 000059 20 910503701936 4000 K Standard Gray 523 000036 05 910503701123 Black 523 000036 13 910503701798 White 523 000036 21 910503701807 Compact Gray 523 000059 05 910503701666 Black 523 000059 13 910503701929 White 523 000059 21 910503701937 eW Burst Powercore Ar...

Page 17: ...e Shield Standard Gray 120 000103 02 910503701214 Black 120 000103 05 910503701422 White 120 000103 08 910503701736 Compact Gray 120 000103 11 910503701825 Black 120 000103 14 910503701739 White 120 000103 17 910503701828 Honeycomb Louver Standard Black 120 000104 00 910503701215 Compact Black 120 000104 01 910503701419 Spread Lenses 14º Standard 120 000080 00 910503700609 Compact 120 000080 04 91...

Page 18: ...ncluding eW Burst Powercore Architectural Installations The provided stainless steel screws for outdoor installations The provided junction box gasket for outdoor installations Unless surface mounting one 4 in 102 mm round US electrical junction box per fixture rated for your application with 3 5 in 89 mm center to center screw holes for attaching the fixture s base Refer to the manufacturer s lit...

Page 19: ...ctural Fixtures to Junction Boxes 1 Mount junction boxes in accordance with the lighting design plan Each fixture is designed for mounting in a 4 in 102 mm round US electrical junction box rated for your application with 3 5 in 89 mm center to center screw holes for attaching the fixture s base 2 If installing fixtures in a series pull 3 conductor copper wire between the junction boxes If installi...

Page 20: ...oor wiring codes 8 If installing in parallel connect the wires from each fixture to the lead wire from the line power source in the common junction box 9 Connect the wire from the first fixture in the series to the line power source if installing in series or from the common junction box to the line power source if installing in parallel Surface Mounting eW Burst Powercore Architectural Fixtures 1...

Page 21: ...connect line neutral and ground and tuck wire connections into the junction box 7 Secure all junction box covers If installing in a damp or wet location seal all junction boxes with contractor grade RTV silicone sealant Use gaskets clamps and other parts and fittings required to comply with local outdoor wiring codes 8 If installing in parallel connect the wires from each fixture to the lead wire ...

Page 22: ...line power to a common junction box and from the common junction box to each fixture s junction box We recommend the use of 12 AWG 2 05 mm stranded 3 conductor copper wire 3 Thread the locking nut onto the eW Burst Powercore Landscape threaded post 4 If installing in a damp or wet location insert the fixture cable through a junction box gasket before making wire connections When attaching the junc...

Page 23: ... installing eW Burst Powercore fixtures to a wall or overhead use a safety cable to tether it to a secure anchor point When dictated by local or state code or advised by a structural engineer attach a safety cable to the eW Burst Powercore fixture housing and tether it to a secure anchor point 1 Thread a safety cable through the fixture housing as shown 2 Attach the safety cable to the mounting su...

Page 24: ...es are dry If using a spread lens also clean and dry both sides of the spread lens 3 Position the honeycomb louver or spread lens If using the honeycomb louver insert the tab on the honeycomb louver into the notch on the face of the eW Burst Powercore fixture housing If using a spread lens make sure that the beam angle designation on the edge of the lens is face up Handle the spread lens by the ga...

Page 25: ... glare shield with both hands flex it gently open and clip it to the front rim of the fixture housing 6 Insert the locking screw into the opening on the trim ring or glare shield Use a 5 32 in hex wrench and torque to 6 in lbs 6 Nm For eW Burst Compact Powercore use a 1 8 in hex wrench Standard 5 32 in 6 in lbs max 6 Nm max Compact 1 8 in 6 in lbs max 6 Nm max ...

Page 26: ...ard hex wrenches to secure fixtures firmly in position Aiming and Locking eW Burst Powercore Landscape Fixtures 1 Using a 6 mm hex wrench loosen the locking nut on the side of the fixture base 2 Aim the fixture by tilting the beam as desired 3 When the fixture is aimed as desired re tighten the locking nut to secure the fixture in place Torque to 25 ft lbs 33 9 Nm Do not over tighten 6 mm 25 ft lb...

Page 27: ...the beam as desired Re tighten the locking nuts to secure the fixture in place Torque to 25 ft lbs 33 9 Nm Do not over tighten 2 To rotate the fixture Loosen the locking nuts on either side of the fixture yoke s base using a 1 8 in or 3 mm hex wrench Rotate the fixture as desired Re tighten the locking nuts to secure the fixture in place 1 8 in hex 3 mm hex 360 5 16 in hex 8 mm hex 25 ft lb max 33...

Page 28: ...last ColorBlaze ColorBurst ColorGraze ColorPlay ColorReach iW Reach eW Reach eW Fuse DIMand EssentialWhite eW iColor iColor Cove IntelliWhite iW iPlayer Optibin and Powercore are either registered trademarks or trademarks of Philips Solid State Lighting Solutions Inc in the United States and or other countries All other brand or product names are trademarks or registered trademarks of their respec...

Reviews: