2. Using a standard RJ45 or Ethercon cable for Ethernet, or XLR-5 data cable for
DMX, connect data directly from an Ethernet or DMX controller’s data output
port to a data input port on the first ColorBlaze TRX fixture in a series.
3. If connecting in series for data, connect a data output port on the first fixture to
a data input port on the next fixture in sequence, using a standard RJ45, Ethercon,
or XLR-5 data cable.
4. If connecting in series for power, connect the power output port on the first
fixture to the power input port on the next fixture using a power cable with a
gray Neutrik NAC3FCB Power Connector Type B on one end and a blue Neutrik
NAC3FCA Power Connector Type A on the other end.
PUSH
PUSH
1
5
3
2
4
XLR-5
RJ45
PUSH
1
5
3
2
4
XLR-5
RJ45
To next fixture
E
We recommend using 22 AWG 5-pin
XLR shielded cable with all five pins wired.
E
For EMI suppression, loop each XLR-5
cable and snap the included ferrite core
onto the cable as close as possible to the
fixture's data input port.