C-Splash 2
Product Guide
9
3. Verify that all additional supporting equipment (switches, controllers) is in place,
and that all additional parts and tools are available.
Install the Fixtures
C-Splash 2 fixtures can be installed in fresh or salt water to a maximum depth of
15 ft (4.6 m). If your lighting design plan calls for submerging or partially submerging
fixtures (in a fountain or pool, for example), make sure that the mounting location is
dry when installing, addressing, and testing your fixtures.
Make sure the power is OFF before mounting and connecting C-Splash 2 fixtures.
1. When pre-drilled pilot holes are required, you can use the provided C-Splash 2
template or the fixture’s base to mark the three screw holes for each fixture.
2. Mount the fixtures to the mounting surface with three 3/8 in-16 silicon bronze cap
screws and washers.
3. Pull the cables from the fixtures to the power / data supply.
4. Pull each fixture cable through a knockout in the side of the power / data supply.
5. Connect 24 VDC, common, ground, and data to a provided connector, then snap
the connector into the connector terminal inside the power / data supply housing.
Leader Cable dimensions
.4 in
(10 mm)
18 AWG
.1 in (2.5 mm)
W
R
R
W
B
B
Ground
z
R W B
.4 in
(10 mm)
18 AWG
.1 in (2.5 mm)
W
R
R
W
B
B
Ground
z
R W B
C
Do not remove or loosen the fixture’s
sealing bolts, as doing so will destroy
the watertight seal.
CC
.5 in
13 mm
.7 in
18 mm
8.3 in Diameter
212 mm
6.2 in
157 mm
6.5 in Diameter
165 mm
5º
120º
9 in
229 mm
1.6 in
43 mm
1.5 in
38 mm
6.88 in
175 mm
9.5 in
241 mm
10.3 in
262 mm