Installation

C-Splash 2 submersible, color-changing LED fixtures are designed to be installed in 

fresh or salt water to a depth of 15 ft (4.6 m). When using in fountains, basins, or 

other man-made water-based environments, make sure that the mounting locations 

are dry before installing, addressing, and testing your fixtures. C-Splash 2 fixtures are 

not for use in human-occupied installations such as swimming pools and spas.

Owner / User Responsibilities

It is the responsibility of the contractor, installer, purchaser, owner, and user to 

install, maintain, and operate the C-Splash 2 fixture in such a manner as to comply 

with all applicable codes, state and local laws, ordinances, and regulations. Consult 

with the appropriate electrical inspector to ensure compliance.

Installing in Wet or Damp Locations

When installing in wet or damp locations, you must seal all junction boxes and power 

/ data supplies with electronics-grade RTV silicone sealant so that water or moisture 

cannot enter or accumulate in wiring compartments, cables, fixtures, or other electrical 

parts. You must use suitable submersible junction boxes when installing under water. 

Additionally, you must use gaskets, clamps, and other parts required for installation to 

comply with all applicable local and national codes.

Create a Lighting Design Plan 

1.  Determine the appropriate location of each power / data supply in relation to the 

fixtures, and of the fixtures in relation to each other. Refer to the power / data 

supply’s Installation Instructions or Product Guide for guidelines on configuring 

and positioning the power / data supply in relation to the controller.

  With the native 60 ft (18.3 m) Leader Cable supplied with each fixture, you can 

connect up to six C-Splash 2 fixtures to each PDS-150e, or up to two fixtures to 

each PDS-60. Using 18 AWG, 4-conductor stranded copper wire, you can extend 

the cable for each individual fixture to a maximum length of 150 ft (45.7 m), as 

long as the total cable length for each power / data supply does not exceed 400 ft 

(121.9 m). 

  C-Splash 2 fixtures can be submerged or partially submerged, and can be 

 

installed in both fresh water and salt water. The maximum submersion depth is 

 

15 ft (4.6 m). 

2.  On an architectural diagram or other diagram that shows the physical layout of 

the installation, identify the locations of all switches, controllers, power supplies, 

fixtures, and cables.

3.  Each C-Splash 2 fixture comes pre-programmed with a unique serial number. As 

you unpack the fixtures, record the serial numbers in a layout grid (typically a 

spreadsheet or list) for easy reference and light addressing.

4.  Assign each fixture to a position in the lighting design plan. 
5.  To streamline installation and aid in light show programming, you can affix a 

weatherproof label identifying the order or placement in the installation to an 

inconspicuous location on each light fixture’s housing.

Start the Installation

1.  Install all power / data supplies, including any interfaces with controllers. 
2.  Ensure that the number of free power / data supply power ports is adequate.

For complete instructions on how to wire the 

power / data supply, refer to the specific power / 

data supply’s Installation Instructions. For sample 

wiring diagrams, visit www.colorkinetics.com/

support/wiring/ls_prod.html.

Refer to the C-Splash 2 Installation Instructions for 

specific warning and caution statements.

C-SPLASH 2 SHOULD NOT BE USED IN HUMAN-OCCUPIED UNDERWATER LOCATIONS, 

SUCH AS POOLS AND SPAS.

C-Splash

® 

2

C K

I N T E L L I G E N T S E R I E S

FOR USE UNDER ONE OR MORE OF THE FOLLOWING U.S. 

PATENTS AND THEIR FOREIGN COUNTERPARTS:

6,016,038, AND 6,150,774.

TURN POWER OFF BEFORE INSTALLING OR REPLACING. NO USER SERVICEABLE PARTS.  

DO NOT OPEN.  REMOVE FIXTURE FROM SERVICE IF DAMAGED. 

FOR USE ONLY WITH COLOR KINETICS CLASS 2 UL/cUL LISTED POWER SUPPLIES

REFER TO INSTALLATION INSTRUCTIONS FOR ADDITIONAL WARNINGS AND USER INFORMATION.

SUITABLE FOR OPERATION IN; WET LOCATIONS (IP68), 

AMBIENT TEMPERATURES NOT EXCEEDING 50°C

(t

a

=50°C).

88UF

INPUT 24V 

===

,

25W Max. 

No-Niche Submersible Luminaire

(Also listed as Low Voltage Luminaire) 

88UF

www.colorkinetics.com

0000 00

DC: 0752 ABC 1234

FFAB0099

Item: 999-999999-99

ABCD abcd ABCD abcd 24CHR

ABCD abc 40CHR

12NC: 9104 036 00112

S/N:

Record fixture serial numbers

C-Splash 2 is not for use in human-occupied 

installations such as pools and spas. Philips 

Color Kinetics provides LED-based pool and spa 

illumination products through its partners Balboa 

Instruments and Hayward Pool Products. 

Summary of Contents for C-Splash 2

Page 1: ...C Splash 2 Submersible color changing LED spotlight for use in fresh and salt water ...

Page 2: ...llers including iPlayer 3 and Light System Manager as well as third party DMX controllers Versatile light positioning Locking base and pivot allows vertical and horizontal rotation through a full 360 Temperature monitoring C Splash 2 has a temperature monitoring feature that automatically interrupts operation to protect the fixtures from damage due to extreme operating temperatures C Splash 2 is a...

Page 3: ...ace into a spectacular light and water show The entire system spans 25 DMX universes for individual control of each C Splash 2 fixture This precise level of control allowed the lighting designer to devise a series of eye catching sequences and seamless transitions including intricate patterns and psychedelic colors that complement video images projected onto a waterwall rising 150 ft behind the la...

Page 4: ...4 The dynamic effects of Philips Color Kinetics technology can also be seen in the resort s resident show Le Rêve The theater in the round set incorporates 300 C Splash 2 units to light the central pool and water based effects ...

Page 5: ...583 182 79 43 24 13 5 0 0 1996 1689 583 182 79 43 24 13 5 0 0 1996 1689 583 182 79 43 24 13 5 0 0 Polar Candela Distribution RCC Ceiling reflectance percentage RW Wall reflectance percentage RCR Room cavity ratio Effective Floor Cavity Reflectance 20 RCC 80 70 50 30 10 0 RW RCR 0 1 2 3 4 5 6 7 8 9 10 70 50 30 0 1 19 1 19 1 19 1 19 1 14 1 11 1 09 1 06 1 08 1 04 1 00 97 1 03 97 93 89 99 92 87 83 95 ...

Page 6: ...ed or Ethernet Control System Philips full range of controllers including Light System Manager and iPlayer 3 or third party DMX controllers Physical Dimensions Height xWidth x Depth 10 3 x 9 x 1 6 in 262 x 229 x 41 mm Weight 22 lb 10 kg Housing Cast brass Lens Clear tempered glass Tempered ground glass Fixture Connections 60 ft 18 3 m unified power data cable Temperature 40 122 F 40 50 C Operating...

Page 7: ...0616 Power data supplies PDS 150e 24V DMX Ethernet 109 000008 01 910503700092 PDS 60 24V Pre programmed 109 000017 00 910503700096 DMX Ethernet 109 000017 03 910503700097 You can use any Philips controller or third party DMX controller Light System Manager Ethernet 103 000015 02 910503700221 iPlayer 3 North America Power Cord DMX 103 000019 00 910403327101 iPlayer 3 Europe Power Cord DMX 103 00001...

Page 8: ...resh water and salt water The maximum submersion depth is 15 ft 4 6 m 2 On an architectural diagram or other diagram that shows the physical layout of the installation identify the locations of all switches controllers power supplies fixtures and cables 3 Each C Splash 2 fixture comes pre programmed with a unique serial number As you unpack the fixtures record the serial numbers in a layout grid t...

Page 9: ...ash 2 template or the fixture s base to mark the three screw holes for each fixture 2 Mount the fixtures to the mounting surface with three 3 8 in 16 silicon bronze cap screws and washers 3 Pull the cables from the fixtures to the power data supply 4 Pull each fixture cable through a knockout in the side of the power data supply 5 Connect 24 VDC common ground and data to a provided connector then ...

Page 10: ...e nuts connect the green ground wire from each fixture Leader Cable to the earth ground on the power data supply 7 Repeat for each power data supply in your installation R W B PDS 150e PDS 60 From C Splash 2 fixtures From C Splash 2 fixtures ...

Page 11: ... Pro can automatically discover all of your fixtures and controllers for quick configuration In DMX installations you can address and configure your fixtures using QuickPlay Pro with iPlayer 3 or SmartJack Pro You can manually enter fixture serial numbers or you can import a spreadsheet listing each fixture s serial number and starting DMX address For complete details on addressing and configuring...

Page 12: ... ColorBlast ColorBlaze ColorBurst ColorGraze ColorPlay ColorReach DIMand EssentialWhite eW iColor iColor Cove IntelliWhite iW iPlayer Light Without Limits Optibin and Powercore are either registered trademarks or trademarks of Philips Solid State Lighting Solutions Inc in the United States and or other countries All other brand or product names are trademarks or registered trademarks of their resp...

Reviews: