C-Splash 2
Product Guide
5
Center Beam fc
Beam Width
2.5 ft
5.0 ft
7.5 ft
10.0 ft
12.5 ft
15.0 ft
2227 fc
557 fc
247 fc
139 fc
89 fc
62 fc
0.4 ft
0.8 ft
1.3 ft
1.7 ft
2.1 ft
2.5 ft
�
�
Beam Spread: 9.6º
�
�
Illuminance at Distance
C-Splash 2
10° clear lens
Polar Candela Distribution
RCC %: Ceiling reflectance percentage, RW %: Wall reflectance percentage, RCR: Room cavity ratio
Effective Floor Cavity Reflectance: 20%
RCC %:
80
70
50
30
10
0
RW %:
RCR: 0
1
2
3
4
5
6
7
8
9
10
70
50
30
0
1.19 1.19 1.19 1.19
1.15 1.14 1.12 1.10
1.12 1.09 1.07 1.04
1.09 1.05 1.02 1.00
1.07 1.02
.99 .96
1.05 1.00
.96 .94
1.02
.97
.94 .91
1.01
.95
.92 .90
.99 .94
.90 .88
.97 .92
.89 .87
.96 .91
.88 .86
70
50
30
0
1.16 1.16 1.16 1.00
1.13 1.11 1.10
.98
1.10 1.08 1.05
.96
1.08 1.04 1.01
.94
1.05 1.01
.98 .92
1.03
.99 .96 .91
1.01
.97 .93 .89
1.00
.95 .92 .88
.98
.93 .90 .87
.97
.92 .89 .86
.95
.90 .87 .85
50
30
20
1.11 1.11 1.11
1.08 1.06 1.05
1.04 1.03 1.01
1.02
.99 .98
.99 .97 .95
.97 .95 .93
.95 .93 .91
.94 .91 .89
.92 .90 .88
.91 .88 .86
.90 .87 .85
50
30
20
1.06 1.06 1.06
1.04 1.03 1.02
1.02 1.00
.99
1.00
.98 .96
.98 .95 .94
.96 .94 .92
.94 .92 .90
.93 .90 .89
.92 .89 .87
.90 .88 .86
.89 .87 .85
50
30
20
1.02 1.02 1.02
1.01 1.00
.99
.99 .98 .97
.97 .96 .95
.96 .94 .93
.95 .93 .91
.93 .91 .90
.92 .90 .88
.91 .89 .87
.90 .88 .86
.89 .86 .85
0
1.00
.98
.96
.94
.92
.90
.89
.87
.86
.85
.84
Coefficients Of Utilization -
Zonal Cavity Method
Zonal Lumen Summary
Zone Lumens % Lamp % Luminaire
0-30
524.4 89.9%
90.1%
0-40
555.1 95.2%
95.4%
0-60
579.9 99.5%
99.6%
60-90
2.1
0.4%
0.4%
0-90
582.0 99.8%
100%
90-180
0
0%
0%
0-180
582.0 99.8%
100%
Total Efficiency: 99.8%
Zonal Lumen
Center Beam fc
Beam Width
2.5 ft
5.0 ft
7.5 ft
10.0 ft
12.5 ft
15.0 ft
319 fc
80 fc
35 fc
20 fc
13 fc
9 fc
0.9 ft
1.9 ft
2.8 ft
3.8 ft
4.7 ft
5.6 ft
�
�
Beam Spread: 21.3º
�
�
Illuminance at Distance
C-Splash 2
22° frosted lens
Candela Table
0
5
15
25
35
45
55
65
75
85
90
0 22.5 44 67.5 90
1996
1689
583
182
79
43
24
13
5
0
0
1996
1689
583
182
79
43
24
13
5
0
0
1996
1689
583
182
79
43
24
13
5
0
0
1996
1689
583
182
79
43
24
13
5
0
0
1996
1689
583
182
79
43
24
13
5
0
0
Polar Candela Distribution
RCC %: Ceiling reflectance percentage, RW %: Wall reflectance percentage, RCR: Room cavity ratio
Effective Floor Cavity Reflectance: 20%
RCC %:
80
70
50
30
10
0
RW %:
RCR: 0
1
2
3
4
5
6
7
8
9
10
70 50 30
0
1.19 1.19 1.19 1.19
1.14 1.11 1.09 1.06
1.08 1.04 1.00 .97
1.03 .97 .93 .89
.99 .92 .87 .83
.95 .87 .82 .78
.91 .83 .78 .74
.87 .79 .74 .70
.84 .76 .71 .67
.81 .73 .68 .64
.79 .70 .65 .62
70 50 30
0
1.16 1.16 1.16 1.00
1.11 1.09 1.07 .94
1.06 1.02 .98 .89
1.01 .96 .92 .84
.97 .91 .86 .79
.93 .86 .81 .75
.90 .82 .77 .72
.86 .79 .74 .69
.83 .75 .70 .66
.80 .72 .68 .63
.78 .70 .65 .61
50 30 20
1.11 1.11 1.11
1.05 1.03 1.01
.99 .96 .93
.93 .90 .87
.89 .85 .81
.84 .80 .77
.81 .76 .73
.77 .73 .70
.74 .70 .67
.72 .67 .64
.69 .65 .62
50 30 20
1.06 1.06 1.06
1.01 1.00 .98
.96 .93 .91
.91 .88 .85
.87 .83 .80
.83 .79 .76
.79 .75 .72
.76 .72 .69
.73 .69 .66
.71 .67 .64
.68 .64 .61
50 30 20
1.02 1.02 1.02
.98 .97 .96
.93 .91 .90
.89 .86 .84
.85 .82 .80
.81 .78 .76
.78 .75 .72
.75 .72 .69
.72 .69 .66
.70 .66 .64
.68 .64 .61
0
1.00
.94
.88
.83
.78
.74
.71
.68
.65
.62
.60
Coefficients Of Utilization -
Zonal Cavity Method
Zonal Lumen Summary
Zone Lumens % Lamp % Luminaire
0-30
390.9 75.9%
76%
0-40
441.3 85.7%
85.8%
0-60
496.4 96.4%
96.5%
60-90
18.0
3.5%
3.5%
0-90
514.5 99.9%
100%
90-180
0
0%
0%
0-180
514.5 99.9%
100%
Total Efficiency: 99.9%
Zonal Lumen
Photometrics
Photometric data is based on test results from an independent NIST traceable testing
lab. IES data is available at www.colorkinetics.com/support/ies.
For lux multiply fc by 10.7
118 ft (36 m)
1 fc maximum distance
44.6 ft (13.6 m)
1 fc maximum distance
Candela Table
0
5
15
25
35
45
55
65
75
85
90
0 22.5 44 67.5 90
1996
1689
583
182
79
43
24
13
5
0
0
1996
1689
583
182
79
43
24
13
5
0
0
1996
1689
583
182
79
43
24
13
5
0
0
1996
1689
583
182
79
43
24
13
5
0
0
1996
1689
583
182
79
43
24
13
5
0
0
Cd: 0
2,319
4,639
6,958
9,277
11,597
13,916
VA: 0º
10º 20º
30º
40º
90º
80º
70º
60º
50º
�
- 0º H
�
- 90º H
Cd: 0
333
665
998
1,331
1,663
1,996
VA: 0º
10º 20º
30º
40º
90º
80º
70º
60º
50º
�
- 0º H
�
- 90º H
LED Lumens
Watts Efficacy
RGB
583
25
23.3
LED Lumens
Watts Efficacy
RGB
515
25
20.6