7.2.2 NA
a) Detachable mains cord inlet has to withstand minimal 2500 insertions and withdrawals.
b) Mains cord operating force should be within the following limits:
•
Withdrawal Force, P: 10N
≤
P
≤
50N
•
Insertion Force, F:
F
≤
50N
7.3 Visibility of User Interface Displays & Indicators
NA
7.3.1 Viewing
Angle
The visibility of display is possible under a viewing angle of 30˚from Top, Bottom, Left and Right.
Note: Viewing angle with regard to the perpendicular at the front of the apparatus.
7.3.2 Display
illumination
The display / segment illumination should be uniform without undesirable light concentrations.
7.3.3 Brightness
As per reference. BDP2100.
7.3.4 Light
Leakage
No light leakage is allowed (e.g. at connector sockets).
Above to be judge in dark condition to a bright condition of 600-800 lux
7.4 Screw
Fixations
The screw fixations have to be designed in such a way, that after 10 times screwing and unscrewing, no
decrease of the quality of the fixation occurs.
The dimensions of thermoplastic bosses, intended for screw-fixations, have to be designed in such a way that
no deterioration of the fixation can take place, taken into account the environment conditions.
7.5 Support
Foot
7.5.1
Type of material
Refer to MUS [3] for the type of material used.
1. Material for the support foot cannot shrunk in such a degree, e.g. after the Cyclic Humidity Test of 21
x 24 hours, that the set touches the furniture or other equipment during shifting. Minimum of 1mm
height should still be attained.
2. Material of the support foot cannot leave stains on furniture surfaces after climatic tests e.g. 70deg x
96hr.
3. The support foots shall prevent the set from moving over the underneath surface while normally
operating the set.
2-7