background image

You cannot receive free warranty service under the following conditions:
1. Damage by improper operation, such as improper components connection, improper
    installation, deprived of manual use, mis-operation.
2. Negligence and damage because of transportation or other accident.
3. Maintenance and modification without approval.
4. Other damage caused by force majeure (such as natural disaster, abnormal voltage, etc.).
5. Damage caused by general use outside home (e.g. industrial and commercial use).
6. Aging, wearing and tearing caused by normal operation of the product without affecting
    normal operation of the product.

This statement serves as a publicity for free maintenance within the specified time limit and
conditions, and does not limit the legal rights of consumers.

12  Packing list

Dispenser
Water drain
User Manual
Quick Start Guide
Cleaning brush

1x
1x
1x
1x
1x

20

Summary of Contents for ADD6910

Page 1: ...ADD6910 淨水器 RO純淨飲水機 Water Purifier RO Dispenser 使用說明書 1 10 User Manual 11 20 ...

Page 2: ...產品功能 1 1 6 主要技術參數 2 1 結構示意圖 3 2 操作與顯示介面 4 2 安裝步驟 5 3 使用說明 6 3 注意事項 7 5 日常保養 8 6 濾芯更換 8 9 故障診斷 9 產品保修服務指南 10 11 裝箱清單 12 10 目錄 繁體中文 ...

Page 3: ...的 水溫 可方便地用於製作各類飲品 機身內附有一體複合濾芯 通過有效的過濾系統及UV殺菌功能 可 清除自來水中99 999 的細菌和病毒 99 9 的重金屬 農藥殘留及餘氯 基於國際認證測試機構BV於實驗室條件下測得 1 產品功能 2 主要技術參數 產品名稱 額定電壓 額定總功率 加熱功率 濾芯額定總淨水量 適用水源 進水壓力 進水水溫 濾水能力 ADD6910 220 V 240 V 2200 W 2100 W 2000 L 本地自來水 0 0 06 MPa 5 38 0 13 L min ...

Page 4: ...Ambient 定制按鍵 童鎖鍵 C 500ml 300ml 210ml 150ml 淨水箱 外觀不可見 顯示面板 原水箱 電源線 單向閥 原水箱蓋 一體複合濾芯 濾芯蓋 出水鍵 出水燈 出水嘴 接水盤 UV LED殺菌指示燈 換水指示燈 濾芯壽命指示燈 水量鍵 水溫鍵 濾水指示燈 出水溫度可能存在 3 的溫度 差 水量可能存在 10 的容量 差 實際出水水溫及水量可能受使用環境及當地水質影響 會存在偏差 95 Customize Child lock ...

Page 5: ...水指示燈 閃爍時 不可取水 2 取水 根據所需的水溫和杯量 選擇水溫 水量 顯示幕顯示當前選擇的水 溫 點擊 童鎖鍵 常溫水自動解鎖 後 點按出水即可取出 相應溫度 水量的淨水 再點按出水鍵或任意鍵都可停止出水 持續出水 長按出水鍵3秒 持續出水 最大出水量為1L 注意 取熱水時 不可把手伸向出水嘴下方 以免熱水燙傷 2 首次使用 首次使用時 需觀察機器在使用過程中產品內部是否有水流出或周邊積水 機器內部是否有異常聲音 焦糊味 煙等 如發現上述情況請斷開電源連接並與售後人員聯繫 首次使用或長期未使用時 應裝滿水箱 在濾水完成後使用一鍵排空功能 即長按 85 C鍵 和 300ml鍵 3秒 如此反復操作兩次 注意 為防止乾燒 機器首次通電取熱水時 將先取出一段常溫水 再取出熱水 45 Ambient Customize Child Lock C 210ml 150ml 3S ...

Page 6: ...水倒出 再往原水箱 裏注滿水後裝回機器並蓋好 注意 切勿在未倒掉濃縮水的情況下直接往原水箱中加水 原水箱換水後請蓋好原水箱蓋 否則 換水指示燈 也會點亮 4 沖洗 機器通電並蓋上原水箱蓋 在機器濾水前和濾水完成後進入沖洗狀態 強制沖洗 同時長按 常溫水鍵 童鎖鍵 3秒鐘機器自動 進入自動沖洗3分鐘 淨水箱處於滿水狀態時不能進行強制沖洗 5 一鍵排空 長按 85 C 鍵 和 300ml鍵 3秒 機器進入一鍵排空狀 態 此時機器的出水嘴開始出水 直至淨水箱排空 注意 一鍵排空操作時 請準備大於2L的容器用於接排出水 C C C C C C C 95 85 45 Ambient Customize C 500ml 300ml 210ml 150ml 95 85 45 Ambient Customize Child Lock C 500ml 300ml 210ml 150ml 95 85 45 A...

Page 7: ...菌10分鐘 當UV LED殺菌模組工作時 UV LED指示燈 常亮 當UV LED殺 菌模組不工作時 UV LED指示燈 熄滅 8 休眠模式 1分鐘內沒有任何操作 機器進入休眠狀態 機器在休眠狀態中 除 童鎖鍵 常亮外其他所有指示燈熄滅 機器在休眠狀態中 觸摸任意鍵 喚醒機器 5 7 注意事項 警告 本産品使用原水水質爲政府供應食水 不明水源請勿使用 應看管好兒童 避免他們將産品當作玩具 請務必非常小心地處理濾芯 請勿改裝或跌撞濾芯 如果濾芯已經過改裝 外部損壞或跌撞過 請加以 更換 本産品僅限於家用 注意 請注意小心輕放 以免産品跌撞造成砸傷 2 45 Ambient Customize Child Lock C 210ml 150ml 3S 1 ...

Page 8: ...清洗完畢後 方可使用 本機器的維修保養需使用指定的部件或配件 嚴禁使用汽油等有機溶劑擦拭本機外殼 確需清潔時 應斷電後用濕抹布輕擦本產品表面 倘若發生故障 應立即關掉電源 切勿將有缺陷的機器置於工作狀態 隨著產品的升級 說明書上的某些文字或圖案 可能與實際有所不同 請以產品實物為準 本機器建議在海拔高度不高於1200m的地區使用 如果用戶先取熱水後馬上取常溫水或45 的水 會先出一段殘留熱水 請注意防止燙傷 建議先放常溫 水10秒後再取水 如果電源軟線損壞 請停止使用機器 為了避免危險 必須由製造商的專業人員更換 請勿擅自拆解維修本機器或交由非授權的售後人員維修 因不當的維修可能造成危險 8 日常保養 1 如果兩天以上不使用 建議更換原水箱的水並進行兩次一鍵排空操作 長按 85 鍵 和 300ml鍵 2 如果計劃長期 一周左右 不使用機器 請先排空機器中和水箱裏的水 斷開電源並將濾芯密封好...

Page 9: ...1 濾芯壽命顯示 濾芯壽命指示燈 顔色代表濾芯剩餘壽命概況 藍色時 表示濾芯 剩餘壽命大於10 紫色時 表示濾芯剩餘壽命小於10 紅色時 表示濾 芯剩餘壽命小於7天或壽命到期 2 濾芯更換步驟 拔出電源 按下濾芯蓋旋鈕 濾芯蓋彈出 將需要更換的濾芯逆時針旋轉至開鎖位置並提出 將新的濾芯塞進機器並順時針旋入至鎖上位置 然後蓋上濾芯蓋 恢復機器電源 長按 常溫水鍵 和 150ml鍵 鍵3秒鐘時間 樂音提示3聲 重置濾芯壽命計算器 濾芯指示燈恢復藍色 按首次使用進行兩次一鍵排空操作 名稱 一體複合濾芯 MAX 型號 ADD550 建議更換週期 1年 1 2 2 1 取出 安裝 ...

Page 10: ...取水操作 先取用幾次常溫水 再取其他溫度的熱水 檢查原水箱蓋是否合攏到位 檢查原水箱是否正確安裝 拔出電源 打開濾芯蓋 將濾芯拆下後重新安裝到位 機器啓動 強制沖洗 1 3次 把氣堵排除 更換濾芯後重新觀察 清空接水盤 用小頂針或手指頂住密封閥動作 將異物移除 關閉電源及水源 請聯繫售後人員 取2個原水箱水量濾水並排空淨水箱 取2個原水箱水量濾水並排空淨水箱 更換濾芯 請聯繫售後人員 必須使用有可靠接地的插座 請聯繫售後人員 請聯繫售後人員 關閉電源1 2分鐘 再重新連接電源 等待片刻 當 濾水指示燈 常亮或熄滅顯 示時即可正常取熱水 請提出原水箱進行換水 然後觀察濾水時是否 有異常聲音 請提出原水箱進行換水 然後觀察濾水時是否有 異常聲音 用小頂針將單向閥調整歸位或聯繫售後人員更換 單向閥 淨水箱 非原水箱 缺水 淨水箱 非原水箱 缺水 原水箱水位處於低水位狀態 原水箱水位處於低水位狀態...

Page 11: ...服務 此免費服務不包括需時常更換的易耗零配件 凈水器濾芯 凈水壺濾芯 活性炭 樹脂 超濾膜片等 輔助裝置 運輸費及維修人員上門服務費 維修時請攜同購買憑證正本方爲有效 故障代碼 取300ml常溫水 如仍然無法解除警報 請聯繫 售後維修人員 檢查原水箱座的單向閥是否到位 如不到位 用 小頂針將單向閥調整歸位或聯繫售後人員更換 單向閥 EH 加熱體高溫 故障代碼 E4 E1 E2 故障原因 加熱體異常 原水溫度探測器異常 加熱體溫度探測器異常 解決方案 聯繫售後維修人員 聯繫售後維修人員 聯繫售後維修人員 暫停使用 等待加熱體溫度恢復正常後 該警報 會自動解除 EH消失 E8 EU TDS探測器異常 通訊警報 聯繫售後維修人員 聯繫售後維修人員 溢水警報 E9 ...

Page 12: ...適當配件 不適當之安裝 不依說明書使用 錯 使用或疏忽而 造成損壞等 2 因運輸及其他意外而造成之損壞 3 非經本公司認可之維修和改裝 4 其他因不可抗力 如自然災害 電壓異常等 造成的損壞 5 一般家庭以外使用 如工業 商業用等 而造成的損壞 6 正常使用引起的產品老化 磨損等 但不影響產品的正常使用 該說明作爲在規定期限及條件之內進行免費維修的宣貫 並不限制消費者的法定權利 12 裝箱清單 主機 接水盤 使用說明書 快速入門指南 清潔刷 1x 1x 1x 1x 1x ...

Page 13: ...請保留此說明書以便查閱 ...

Page 14: ...ifications 2 11 Product overview 3 12 User interface 4 12 Installation 5 13 Usage instruction 6 13 Precautions 7 15 Routine maintenance 8 16 Filter cartridge change 18 19 Trouble shooting 9 Guarantee Service 10 11 Packing list 12 20 CONTENTS English ...

Page 15: ...drinks and beverages The innovative all in one RO filtration system and UV LED guarantee cleanness of water by removing up to 99 999 bacteria and virus 99 9 heavy metal pesticides and chlorine 1 Product introduction 2 Main technical specifications Product model Rated voltage Total rated power Heating power Applicable water source Inlet water pressure Inlet water temperature Water filtration flow r...

Page 16: ...here could be a temperature deviation of 3 There could be a volume deviation of 10 the actual temperature and volume depends on using environment and local tap water quality Extraction indicator light Nozzle 85 45 Ambient C 500ml 300ml 210ml 150ml Indicator of UV LED sterilization Indicator of changing water Indicator of filter lifetime Volume selection button Temperature selection button Indicato...

Page 17: ...lected Tap the extraction button once to get the water you choose Tap it again or tap any other button to stop Continuous water extraction Long press water extraction button for 3 seconds The maximum volume extracted is 1 L for a time Note To avoid being scalded keep the distance from the nozzle during extracting hot water 2 First time using During first time use please check if any water leaks fr...

Page 18: ...48 hours Empty and refill the raw water tank in these cases Note Never refill the raw water tank before emptying it Cover the raw water tank lid after changing the water otherwise the Indicator of changing water will keep flashing 4 Rinsing The dispenser will do auto rinsing before and after water filtration once it is connected with power supply and the raw water tank is covered Forced rinsing lo...

Page 19: ...ll be off 8 Sleep mode If no operation in 1 minute the dispenser will automatically go to sleep mode When the dispenser is in sleep mode the lights of all buttons are off except the Child lock button Touch any button to end the sleep mode 7 Precautions Warning Use municipal tap water as the source Do not use any water of unknown source Keep the dispenser away from children Be sure to handle the di...

Page 20: ...ith wet cloth after it is disconnected from power supply If there is any abnormality unplug the product from power supply immediately and do not leave the defective dispenser in working mode With upgrade of the product certain words or pictures on the manual may be different from the actual product and the actual product shall govern in this case The dispenser is suggested to be used in areas whos...

Page 21: ...time for the filter cartridge as follows Blue more than 10 lifetime left Purple less than 10 lifetime left Red less than 7 day lifetime left 2 Filter cartridge replacement instruction Unplug the product from power supply Press the button on the cover of filter cartridge and the cover will pop up Rotate the old filter cartridge counterclockwise to the unlocked position and take it out Insert the ne...

Page 22: ...s from the dispenser Raw water tank lid is not well covered Check the raw water tank lid and cover it Raw water tank is not installed properly Check the raw water tank and install it properly Force rinsing for 1 3 times Change the filter cartridge and check it again Cartridge is not installed properly Filtering system is blocked by air Disconnect the dispenser from the power supply Open the cartri...

Page 23: ...ice personnel during maintenance Heating element abnormality Raw water temperature sensor abnormality Heating element temperature sensor abnormality Heating element overheats TDS sensor abnormality The dispenser overflows Communication abnormality Contact customer services Contact customer services Contact customer services Stop using the dispenser and wait for the heating element to cool down to ...

Page 24: ...amage caused by force majeure such as natural disaster abnormal voltage etc 5 Damage caused by general use outside home e g industrial and commercial use 6 Aging wearing and tearing caused by normal operation of the product without affecting normal operation of the product This statement serves as a publicity for free maintenance within the specified time limit and conditions and does not limit th...

Page 25: ...Please keep this user manual for future reference ...

Page 26: ... has been manufactured by and is sold under the responsibility of Shanghai AquaShield Health Technology Company Limited and Shanghai AquaShield Health Technology Company Limited is the warrantor in relation to this product Rev A AUG 19 Specifications are subject to change without notice www philips com welcome Register your product and learn more in the website link below ...