Before calling Service                                                                                       

Ambient temperature

Do not hang up the monitor above a
central heating or other heating sources.
If the power/standby indicator in front is
red and blinking, the temperature inside
the monitor has become too high and has
activated the protector.The monitor will
be turned off. Unplug the power cord and
wait for the monitor to cool down.

Care of the screen

Clean the anti-reflex coated flat glass
screen with a slightly damp soft cloth. Do
not use abrasives solvents as it can
damage the glass surface of the screen.

Plasma Display characteristics

Caution

: A video source (such as a video

game, DVD, or video information channel)
which shows a constant non-moving
pattern on the monitor, can cause damage
to the screen.When your Flat-Monitor is
continuously used with such a source, the
pattern of the non-moving portion of the
game (DVD, etc.) could leave an image
permanently on the screen.When not in
use, turn the video source 

OFF

.

To prevent or to reduce burn-in of the
screen, select a 

LONG LIFE

setting in the

OPTIONS1

menu. See p. 8.

Very incidentally and after a longer period
of unuse (approx. 1 year) the screen may
display some strange colour deficiencies.
This is quite normal for plasma displays
and these effects will disappear after the
set has been turned on for some time.

A plasma display consists of more than 1,2
Million colour pixels. It is within industry
standards that very few pixels (< 0.001%)
may be defective, even for a new set.
There is however no reason to doubt
about the quality of the set.

The plasma display technology operates
with rare gases which are being influenced
by air pressure. Up to an altitude of
2000m above sea-level (local air pressure
equal or above 800 hPa), the display is
functioning fine. Operating the set at a
higher altitude (lower air pressure), the
picture becomes unstable and the picture
performance is deteriorating.

The plasma display might then also
produce a humming sound. After bringing
the set below 2000 m (local air pressure
equal or above 800 hPa) it works fine
again.Transportation has no influence.

Control of peripheral equipment

The infrared radiation of the screen may
influence the reception sensitivity of other
peripherals. Solution: replace the batteries
of the remote control or change position
of other equipment. E.g. keep away a
wireless headphone from within a radius
of 1,5 m.

No stable or not synchronised VGA
picture

Check if you have selected the correct
display mode in your PC. See Table of
Signal Supported.

No picture 

Are the supplied cables connected
properly? (The power cable to the display,
the VGA  cables,...)
Is your PC switched on?
Do you see a black screen and the
indicator in front of the monitor lights up
green, this means that the display mode is
not supported.
Switch your VGA source to a correct
mode.

Remote control

If your monitor no longer responds to the
remote control, the batteries may be
exhausted.

If your problem is not solved:

Switch your monitor off and then on
again.

Never attempt to repair a defective
monitor yourself.

Check with your dealer or call a video
technician.

Transport

Keep the original packaging to transport the
monitor if needed.

End of life directives

Philips is paying a lot of attention to
produce environmentally-friendly in green
focal areas.Your new monitor contains
materials which can be recycled and
reused.
At the end of its life specialised companies
can dismantle the discarded monitor to
concentrate the reusable materials and to
minimise the amount of materials to be
disposed of.
Please ensure you dispose of your old
monitor according to local regulations.

How to dispose of batteries ?

The batteries supplied do not contain the
heavy metals mercury and cadmium.
Nevertheless in many countries batteries
may not be disposed of with your
household waste. Please ensure you dispose
of batteries according to local regulations.

Miscellaneous

. Ambient temperature: + 5~ + 40°C
. Maximum operating altitude:

2000 m/6526 ft
(min. air pressure 800hPa)

. Mains: AC 100-240V
. Standby consumption: 1 W
. Weight (excl. packaging)

Display: 46 kg

. Dimensions (wxhxd):

Display: 124,2 x 76,7 x 11 inch 

. Wall mounting bracket included

Settings are out of adjustment 

Select 

RESET

in the 

OPTIONS 1

menu, p. 8

to restore the predefined factory settings.

Before calling Service

126 1022.4 gb  20-12-2002  11:54  Pagina 12

Summary of Contents for 50FD9934/01S

Page 1: ...maged please contact the dealer This plasma display mounting unit is for use only with PHILIPS 50 inch plasma displays Do not use with any other equipment since the equipment could fall and cause injury Do not obstruct the ventilation holes of the plasma display Doing so will prevent the dissipation of heat and may result a fire Do not use the plasma display in the following ways Do not install th...

Page 2: ...urface Remove the plasma display form the carton place the protective sheet that was used in the packaging on a flat surface which is larger than the display then lay the display down on top of this with the screen surface facing downward Special technology is required in the mounting of the plasma display Such work should never be undertaken by the customer For the safety of the customer we ask t...

Page 3: ...or level positioning Note It is recommended that the power cable and various signal cables be plugged into the display before mounting the display After mounting the display plugging in the cables may be difficult If the display is tilted to the left or right the display fitting is not properly placed on the wall mounting unit Slide in the direction of the lower side and adjust for level positioni...

Page 4: ...ft side of the monitor VGA Input for analog RGB signal of PC etc DVI Inputs a PC with a digital RGB signal RS 232c Serial I O port This connector allows you to control your monitor via external equipment e g PC and a replacement of the remote control VGA DVI EXTERNAL CONTROL Connect Peripheral Equipment ...

Page 5: ...r at the rear side of the receiver box Fix the connectors firmly with the screws on the plug é In case of a Multimedia computer connect the audio cable to the audio outputs of your computer and to the AUDIO VGA IN R right and L left inputs of the receiver box Insert the mains plug supplied into the mains inlet at the bottom of the monitor and in the wall socket For safety please only use the suppl...

Page 6: ... picture or restore it if the plasma display is used in the VGA mode When activated a green indicator starts blinking in front of the plasma display q Picture format Press the q key to switch between the different picture formats BRIGHTNESS to adjust the brightness level of the picture CONTRAST to adjust the contrast level of the picture ZOOM ON OFF to activate de activate the zoom function ZOOM I...

Page 7: ...ou to select a picture mode according to the brightness of the environment in which you are viewing the pictures on the monitor display Press the cursor left right to select THEATRE in a dark room NORMAL in a bright room MEMORY to keep the picture adjustments you adjusted yourself RESET to reset the picture to the settings predefined in the factory Colour temperature This control allows you to sel...

Page 8: ... input source screen mode etc to appear on screen during presentation etc OSD ADJ Select OSD ADJ 1 9 to position the menus that appear on screen The position can be set between 1 and 9 POWER MGT only in VGA mode Select POWER MGT ON to turn the power management function on The power management function is an energy saving function and automatically reduces the monitor s power consumption if the com...

Page 9: ... set the timer functions Select WORKING TIME and enter the hours h and minutes m with the cursor keys to select the time the inverse mode has to be active Select WAITING TIME and enter the hours h and minutes m with the cursor keys to select the time after which the inverse mode should become active Select SCREEN WIPER ON or OFF Select ON and press the OK key a white vertical bar is moving from le...

Page 10: ...s select WIDE 2 DTV select this mode when watching digital broadcasting 480p Setting high definition images to the suitable screen size This control allows you to set whether the number of vertical lines of the input high definition image is 1035 or 1080 Select HD SELECT é Press the cursor left right to select the correct HD mode 1080A for special digital broadcasts e g DTC 100 1080B for standard ...

Page 11: ...ES YES YES YES YES YES YES YES FULL 16 9 YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES 3 YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES 6 YES 6 Model Signal Type IBM PC AT compatible computers Work Station EWS4800 Work Station HP Work Station SUN Work Station SGI IDC 3000G PAL625P NTSC525P Supported resolution When the screen m...

Page 12: ...e again Transportation has no influence Control of peripheral equipment The infrared radiation of the screen may influence the reception sensitivity of other peripherals Solution replace the batteries of the remote control or change position of other equipment E g keep away a wireless headphone from within a radius of 1 5 m No stable or not synchronised VGA picture Check if you have selected the c...

Reviews: