PHILIPS 4000 and 3000 05 SERVICE MODE
14/18
Press the Espresso button to move BU to work
Action by user
LED INDICATION
Led
NoBeans
Led
NoWater
Led
GenAlarm
Led Dreg
drawer full
When the BU reaches the work position the Led NoBeans
is switched on
ON
NA
NA
NA
ERROR: Led NoBeans remains off, Check the work mi
-
croswitch (broken?), the BU motor (blocked?) and the wi
-
ring (JP16).
NA
NA
NA
NA
ERROR: led GenAlarm Switch ON; the absorbed current
is much more 300mA (with BU) or 200mA (without BU)
check the BU and the motor
NA
NA
ON
NA
Press the Coffee button to move BU to home
Action by user
LED INDICATION
Led
NoBeans
Led
NoWater
Led
GenAlarm
Led Dreg
drawer full
When the BU reaches the home position the Led NoBeans
is switched on
ON
NA
NA
NA
ERROR: Led NoBeans remains off, Check the work mi
-
croswitch (broken?), the BU motor (blocked?) and the wi
-
ring (JP16).
NA
NA
NA
NA
ERROR: led GenAlarm Switch ON; the absorbed current
is much more 300mA (with BU) or 200mA (without BU)
check the BU and the motor
NA
NA
ON
NA
Finish condition:
With BU, Drag Drawer,
door closed
LED INDICATION
Led
NoBeans
Led
NoWater
Led
GenAlarm
Led Dreg
drawer full
OFF
OFF
OFF
OFF
Level 4 (Pump)
Start condition:
BU not inserted, Drag drawer and
service door closed, no water sensor
LED INDICATION
Led
NoBeans
Led
NoWater
Led
GenAlarm
Led Dreg
drawer full
OFF
OFF
OFF
OFF
If the Dreg drawer is not inserted or the Service door is
not closed the EV cannot be opened and test cannot be
performed. If these 2 inputs are not in the right position,
Led Dreg drawer full will be RED
NA
NA
NA
ON
Start condition:
NO BU, Drag drawer, door
Closed and No Water sensor
LED INDICATION
Led
NoBeans
Led
NoWater
Led
GenAlarm
Led Dreg
drawer full
OFF
OFF
OFF
OFF
If the Dreg drawer is not inserted or the Service door is
not closed the BU test cannot be performed. If these 2
inputs are not in the right position, Led Dreg drawer full
will be RED
NA
NA
NA
ON
Level 3 (Brewing unit)
Press BUTTON Stand-By to move to the next screen
Press BUTTON Stand-By to move to the next screen
Summary of Contents for 3000 series
Page 3: ...PHILIPS 4000 and 3000 CHAPTER 1 INTRODUCTION ...
Page 10: ...PHILIPS 4000 and 3000 CHAPTER 2 TECHNICAL SPECIFICATIONS ...
Page 16: ...PHILIPS 4000 and 3000 CHAPTER 3 BRIEF INSTRUCTIONS ...
Page 30: ...PHILIPS 4000 and 3000 CHAPTER 4 OPERATING LOGIC ...
Page 41: ...PHILIPS 4000 and 3000 CHAPTER 5 SERVICE MODE ...
Page 60: ...PHILIPS 4000 and 3000 CHAPTER 6 SERVICE AND MAINTENANCE ...
Page 63: ...PHILIPS 4000 and 3000 CHAPTER 7 DISASSEMBLY ...
Page 73: ...PHILIPS 4000 and 3000 CHAPTER 8 NOTES ...
Page 74: ...PHILIPS 4000 and 3000 08 NOTES 1 1 ...
Page 75: ...PHILIPS 4000 and 3000 CHAPTER 9 WATER CIRCUIT DIAGRAM ...
Page 77: ...PHILIPS 4000 and 3000 CHAPTER 10 ELECTRICAL DIAGRAM ...
Page 78: ...PHILIPS 4000 and 3000 10 ELECTRICAL DIAGRAM 1 2 Philips 4000 ...
Page 79: ...PHILIPS 4000 and 3000 10 ELECTRICAL DIAGRAM 2 2 Philips 3000 ...