Meridian 3 111
Fig. 2: 2 monitors standing back to back.
The monitors may influence each other. So Monitor 1 may produce unexpected brightness-switches in monitor 2
(and vice versa). Furthermore, user 1 could perhaps (via monitor 1) influence the powersensor readout on monitor 2.
Fig. 3: set up of multiple monitors under an angle
Visual Characteristics
Test conditions
Unless otherwise specified, this specification is defined under the following conditions.
(1) Input signal: As defined in 3.3, Panel Native non-interlaced mode (@75Hz), signal sources
must have 75 ohm output impedance.
(2) Luminance setting: controls to be set to max. Panel brightness with full screen 100 % duty cycle
white signal
(3) Warm up: more than 30 minutes after power on with signal supplied.
(4) Ambient light: 400 -- 600 lux.
(5) Ambient temperature: 20 ± 5
q
C
Brightness
Follow Panel specification.
Color temperature adjustment
There are three factory preset white color 9300K, 6500K, sRGB.
Apply full white pattern, with brightness in 100 % position and the contrast control at 50 % position.
The 1931 CIE Chromaticity (color triangle) diagram (x, y) coordinate for the screen center should be: