background image

 

Report Period

 

0x7FFF

 

3

 

Threshold of 
current for Load 
caution

 

2

 

10-1100

 

0.01A

 

1100

 

1100*0.01A = 11A

 

4

 

Threshold of 
KWh for Load 
caution

 

2

 

1-10000

 

1KWh

 

10000

 

 

5

 

Restore switch 
state mode

 

1

 

0-2

 

 

 

1

 

0 : Switch off 

1 : Last switch state 

2 : Switch on

 

6

 

Manual On/Off 
mode

 

1

 

0-1

 

 

1

 

0

Disable 

manual On/Off 

1

Enable 

manual On/Off

 

7

 

LED indication 
mode

 

1

 

1-3

 

 

1

 

1 : Show switch state 

2 : Show night mode 

3 : One flash mode

 

8

 

Auto off timer

 

2

 

0-0x7FFF

 

1s

 

0

 

0 : Disable auto off 

function 

1-0x7FFF : 1s ~ 

32767s

 

9

 

RF off 
command mode

 

1

 

0-3

 

 

0

 

0 : Switch off 

1 : Ignore 

2 : Switch toggle 

3 : Switch on

 

10

 

Edge or Pulse 

mode or 

Edge-Toggle 

mode

 

1

 

1-3

 

 

1

 

1

Edge mode 

2

Pulse mode 

3

Edge-Toggle mode

 

11

 

Manual  Switch 

Report mode

 

1

 

0-1

 

 

1

 

0 : Disable 

1 : Enable

 

 

3-1

 Watt 

Meter Report Period: 

    If the setting is configured for 1hour (set value =720), the PAN03/PAN10 will report 

its  instant  power  consumption  every  1  hour  to  Group1  node.    The  maximum 
interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr). 

 

3-2 KWH Meter Report Period: 

      If the setting is configured for 1hour (set value =6), the PAN03/PAN10 will report its 

Accumulated  Power  Consumption  (KW/h)  every  1  hour  to  Group1  node.    The 
maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 
days (10min*32767/1440=227.55 days). 

 

3-3 Threshold of current for Load Caution 

This  is  a  warning  when  the  current  of  load  over  the  preset threshold  value,  if  the 

setting  value  is  1100,  when  the  load  current  of  Relay1  over  this  value, 
PAN03/PAN10 will send current meter report to warn the Group1 node, the Range 
of the setting value is from 10 to 1100, and the default value is 1100. 

3-4 Threshold of KWh for Load Caution 

This  is  a  warning  when  the  KWh  of  load  over  the  preset  threshold  value,  if  the 
setting value is 10000, when the Accumulated Power Consumption of Relay1 over 
this value, PAN03/PAN10  will send KWH meter report to warn the Group1 node, 
minimum value is 1KWh and default value is 10000 kWh. 

3-5 Restore switch state mode: 

  Whenever  the  AC  power  return  from  lost,  PAN03/PAN10  will  restore  the  switch 

state which could be SWITCH OFF

LAST SWITCH STATE

SWITCH ON. The 

default setting is LAST SWITCH STATE. 

3-6 Manual On/Off Mode: 

The On/Off function of S1

S2 and learn switch can be disabled or enabled by this 

parameter, default value is Enable. But the learning operation won

’t be affected.   

When manual On/Off function is disabled, the RF command can only switch On 
but not Off. This is useful function for keeping the device in switch on state. 

3-7 LED indication mode: 

  3-7-1 Show Switch State

When switch is on, LED is on. When switch is off, LED is 

off. The default setting is Show Switch State. 

  3-7-2 Show Night mode

When switch is on, LED is off. When switch is off, LED is 

on. 

  3-7-3 One Flash mode

When the state of switch changes, LED will be on only one 

second, then LED keeps off. 

3-8 Auto off timer

 

  Whenever PAN03/PAN10 switches to on, the auto off timer begin to count down. 

After the timer decrease to zero, it will switch to off automatically. However if Auto 
off timer is set as 0, the auto off function will be disabled. The default setting is 0. 

3-9 RF off command mode 

  Whenever  a  switch  off  command,  BASIC_SET

BINARY_SWITCH_SET

SWITCH_ALL_OFF, is received, it could be interpreted as 4 variety of commands.   

3-9-1 Switch Off

It switches to OFF state. The default setting is Switch Off. 

3-9-2 Ignore

The switch off command will be ignored. 

3-9-3 Switch Toggle

It switches to the inverse of current state. 

Summary of Contents for Z-Wave Plus PAN03

Page 1: ... OFF switch PAN03 PAN10 is a security enabled wireless switch based on Z Wave Plus technology Z Wave Plus TM enabled devices displaying the Z Wave Plus TM logo can also be used with it regardless of the manufacturer and can also be used in other manufacturer s Z Wave TM enabled networks Remote On Off ...

Page 2: ...tton on the Switch The table below lists an operation summary of basic Z Wave functions Please refer to the instructions for your Z Wave TM Certificated Primary Controller to access the Setup function and to include exclude associate devices Function Description Annotation No node ID The Z Wave Controller does not allocate a node ID to the Switch 2 second on 2 second off Inclusion 1 Put your Z Wav...

Page 3: ...tors boiler etc 4 After putting it into use the body of Switch will become a little bit hot of which phenomenon is normal Installation 1 Put the in wall switch into a wall box and connect the AC power wire L N to PAN03 PAN10 connector L N 2 Connect the wall switch to the PAN03 PAN10 as Fig1 3 There are 3 mode PAN03 PAN10 can be configured to match different kind of wall switch please refer to 3 10...

Page 4: ... 0x02 Size 4 Meter Value W 2 1 3 Overload alarm report When PAN03 PAN10 detects the current is more than 12A it will send Alarm Report to Group 1 node The content of Alarm Report Alarm report command Command_Class_Alarm Alarm_Report Alarm Type 0x08 Alarm Level 0xFF 2 2 Response to Meter Get Command The Switch will report its 1 instant Power Consumption Watt or 2 accumulated power consumption KWH o...

Page 5: ...alue 2 230 5 V 2 2 5 AC load current I When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x05 I Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x05 Size 2 Meter Value I Example Scale 0x05 I Precision 2 Size 2 2 Bytes of I Meter Value 1 0x01 I Meter Value 2 0x...

Page 6: ...Threshold of KWh for Load Caution This is a warning when the KWh of load over the preset threshold value if the setting value is 10000 when the Accumulated Power Consumption of Relay1 over this value PAN03 PAN10 will send KWH meter report to warn the Group1 node minimum value is 1KWh and default value is 10000 kWh 3 5 Restore switch state mode Whenever the AC power return from lost PAN03 PAN10 wil...

Page 7: ...earn function does not change because learning will not be protected 5 Firmware update over the air OTA PAN03 is based on 500 series SoC and supports Firmware Update Command Class it can receives the updated firmware image sent by controller via the Z wave RF media It is a helpful and convenient way to improve some function if needed 6 Command Classes The Switch supports Command Classes including ...

Page 8: ...g it into use the body of Module will become a little bit hot of which phenomenon is normal Warning 1 Plug out to disconnect from power supply Do not plug in line 2 Do not exceed the max rating Disposal This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste dis...

Page 9: ...on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation...

Reviews: