control of the connected load is possible with other manufact

urer’s wireless Controller. 

Each switch is designed to act as a repeater. Repeaters will re-transmit the RF signal 
to ensure that the signal is received by its intended destination by routing the signal 
around  obstacles  and  radio  dead  spots.  Because  PAN03/PAN10  supports  Security 
Command Class, it can learn with Secured controller. Its functionality and supported 
command classes is identical when included as a secure and non-secure device. 
 

This plug-in ON/OFF switch is able to detect instance wattage and overload current 

(12A with resistive load) of connected lights or appliances. When detecting overload 

state, the Switch will be disabled and its On/Off button will be lockout of which LED will 

flash quickly.    However, unplug and re-connect the switch will reset its overload 

condition to normal status. 

 

Adding to Z-Wave

TM

 Network

 

 
In the front casing, there is an On/Off button with LED indicator which is used to toggle 
switch  on  and  off  or  carry  out  inclusion,  exclusion,  reset  or  association.  When  first 
power is applied, its LED flashes on and off alternately and repeatedly at 0.5 second 
intervals. It implies that it has not been assigned a node ID and start auto inclusion.   
 

Auto Inclusion

 

 
The function of auto inclusion will be executed as long as the switch does not have 
Node ID and just plug the switch into a wall outlet.

 

 
Note:

 Auto inclusion timeout is 2 minute during which the node information of explorer 

frame will be emitted once several seconds. Unlike “inclusion” function as shown in 
the table below, the execution of auto inclusion is free from pressing the On/Off button 
on the Switch. 
 
The table below lists an operation summary of basic Z-Wave functions. Please refer to 
the instructions for your Z-Wave

TM

 Certificated Primary Controller to access the Setup 

function, and to include/exclude/associate devices 
 

Function

 

Description

 

Annotation

 

No node ID

 

The Z-Wave Controller does not allocate 
a node ID to the Switch.

 

2-second on, 2-second off

 

Inclusion

 

1.  Put your Z-Wave controller into 

inclusion mode by following the 
instructions provided by the 
controller manufacturer.

 

 

2.    Pressing On/Off button three times 

within 2 seconds will enter inclusion 
mode.

 

Exclusion

 

1.    Put your Z-Wave controller into 

exclusion mode by following the 
instructions provided by the 
controller manufacturer.

 

 

2.

 

Pressing On/Off button three times 
within 2 seconds will enter exclusion 
mode.

 

Node ID has been excluded.

 

0.5s On, 0.5s Off (Enter 
auto inclusion)

 

Reset

 

1. 

Pressing On/Off button three times 
within 2 seconds will enter inclusion 
mode.

 

Use this procedure only in 
the event that the primary 
controller is lost or 
otherwise inoperable.

 

2. 

Within 1 second, press On/Off 
button again for 5 seconds.

 

3. 

IDs are excluded.

 

0.5s On, 0.5s Off (Enter 
auto inclusion)

 

Association

 

1.  The PAN03 is an always listening 

Z-Wave device, so associations may 
be added or removed by a controller 
at any time. 

Or    If your controller requires to have 

the PAN03 send a 'node information 
frame' or NIF for associations, then 
pressing the On/Off button three 
times within 2 seconds will cause 
the PAN03 to send its NIF.

 

 

2.    There are only one group for the 

switch

 

 

Including a node ID allocated by Z-Wave Controller means inclusion.    Excluding a node 
ID allocated by Z-Wave Controller means exclusion.

Failed or success in including/excluding the node ID can be viewed from the Z-Wave 

Controller. 

 

 

Sometimes people are not easy to execute exclusion or inclusion especially when 

Summary of Contents for Z-Wave Plus PAN03

Page 1: ... OFF switch PAN03 PAN10 is a security enabled wireless switch based on Z Wave Plus technology Z Wave Plus TM enabled devices displaying the Z Wave Plus TM logo can also be used with it regardless of the manufacturer and can also be used in other manufacturer s Z Wave TM enabled networks Remote On Off ...

Page 2: ...tton on the Switch The table below lists an operation summary of basic Z Wave functions Please refer to the instructions for your Z Wave TM Certificated Primary Controller to access the Setup function and to include exclude associate devices Function Description Annotation No node ID The Z Wave Controller does not allocate a node ID to the Switch 2 second on 2 second off Inclusion 1 Put your Z Wav...

Page 3: ...tors boiler etc 4 After putting it into use the body of Switch will become a little bit hot of which phenomenon is normal Installation 1 Put the in wall switch into a wall box and connect the AC power wire L N to PAN03 PAN10 connector L N 2 Connect the wall switch to the PAN03 PAN10 as Fig1 3 There are 3 mode PAN03 PAN10 can be configured to match different kind of wall switch please refer to 3 10...

Page 4: ... 0x02 Size 4 Meter Value W 2 1 3 Overload alarm report When PAN03 PAN10 detects the current is more than 12A it will send Alarm Report to Group 1 node The content of Alarm Report Alarm report command Command_Class_Alarm Alarm_Report Alarm Type 0x08 Alarm Level 0xFF 2 2 Response to Meter Get Command The Switch will report its 1 instant Power Consumption Watt or 2 accumulated power consumption KWH o...

Page 5: ...alue 2 230 5 V 2 2 5 AC load current I When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x05 I Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x05 Size 2 Meter Value I Example Scale 0x05 I Precision 2 Size 2 2 Bytes of I Meter Value 1 0x01 I Meter Value 2 0x...

Page 6: ...Threshold of KWh for Load Caution This is a warning when the KWh of load over the preset threshold value if the setting value is 10000 when the Accumulated Power Consumption of Relay1 over this value PAN03 PAN10 will send KWH meter report to warn the Group1 node minimum value is 1KWh and default value is 10000 kWh 3 5 Restore switch state mode Whenever the AC power return from lost PAN03 PAN10 wil...

Page 7: ...earn function does not change because learning will not be protected 5 Firmware update over the air OTA PAN03 is based on 500 series SoC and supports Firmware Update Command Class it can receives the updated firmware image sent by controller via the Z wave RF media It is a helpful and convenient way to improve some function if needed 6 Command Classes The Switch supports Command Classes including ...

Page 8: ...g it into use the body of Module will become a little bit hot of which phenomenon is normal Warning 1 Plug out to disconnect from power supply Do not plug in line 2 Do not exceed the max rating Disposal This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste dis...

Page 9: ...on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation...

Reviews: