2
control of the connected load is possible with other manufact
urer’s wireless Controller.
Each switch is designed to act as a repeater. Repeaters will re-transmit the RF signal
to ensure that the signal is received by its intended destination by routing the signal
around obstacles and radio dead spots. Because PAN03/PAN10 supports Security
Command Class, it can learn with Secured controller. Its functionality and supported
command classes is identical when included as a secure and non-secure device.
This plug-in ON/OFF switch is able to detect instance wattage and overload current
(12A with resistive load) of connected lights or appliances. When detecting overload
state, the Switch will be disabled and its On/Off button will be lockout of which LED will
flash quickly. However, unplug and re-connect the switch will reset its overload
condition to normal status.
Adding to Z-Wave
TM
Network
In the front casing, there is an On/Off button with LED indicator which is used to toggle
switch on and off or carry out inclusion, exclusion, reset or association. When first
power is applied, its LED flashes on and off alternately and repeatedly at 0.5 second
intervals. It implies that it has not been assigned a node ID and start auto inclusion.
Auto Inclusion
The function of auto inclusion will be executed as long as the switch does not have
Node ID and just plug the switch into a wall outlet.
Note:
Auto inclusion timeout is 2 minute during which the node information of explorer
frame will be emitted once several seconds. Unlike “inclusion” function as shown in
the table below, the execution of auto inclusion is free from pressing the On/Off button
on the Switch.
The table below lists an operation summary of basic Z-Wave functions. Please refer to
the instructions for your Z-Wave
TM
Certificated Primary Controller to access the Setup
function, and to include/exclude/associate devices
Function
Description
Annotation
No node ID
The Z-Wave Controller does not allocate
a node ID to the Switch.
2-second on, 2-second off
Inclusion
1. Put your Z-Wave controller into
inclusion mode by following the
instructions provided by the
controller manufacturer.
2. Pressing On/Off button three times
within 2 seconds will enter inclusion
mode.
Exclusion
1. Put your Z-Wave controller into
exclusion mode by following the
instructions provided by the
controller manufacturer.
2.
Pressing On/Off button three times
within 2 seconds will enter exclusion
mode.
Node ID has been excluded.
0.5s On, 0.5s Off (Enter
auto inclusion)
Reset
1.
Pressing On/Off button three times
within 2 seconds will enter inclusion
mode.
Use this procedure only in
the event that the primary
controller is lost or
otherwise inoperable.
2.
Within 1 second, press On/Off
button again for 5 seconds.
3.
IDs are excluded.
0.5s On, 0.5s Off (Enter
auto inclusion)
Association
1. The PAN03 is an always listening
Z-Wave device, so associations may
be added or removed by a controller
at any time.
Or If your controller requires to have
the PAN03 send a 'node information
frame' or NIF for associations, then
pressing the On/Off button three
times within 2 seconds will cause
the PAN03 to send its NIF.
2. There are only one group for the
switch
Including a node ID allocated by Z-Wave Controller means inclusion. Excluding a node
ID allocated by Z-Wave Controller means exclusion.
Failed or success in including/excluding the node ID can be viewed from the Z-Wave
Controller.
Sometimes people are not easy to execute exclusion or inclusion especially when