Philio PAU01 Manual Download Page 6

3.1. Include Device

Add a Z-Wave device to the Z-Wave network, the controller should 
include it. But before you execute the include operation, please make 
sure that device is not be included to other network. If it is, please 
operate the exclude procedure first. 

To execute the include operation; please press the “Include” button.

The all buttons of the main function part will be disabled. And the 
controller will into to inclusion mode. If you want to abort the include 
operation, please press the “Abort” button in the controller function 
part.

Figure 

Controller into inclusion mode

Now press the learning key on the device, usually the Z-Wave devices 
made from Philio, press the learning key three times the device will 
into the learn mode. If the controller got that message, the UI will 
show a progress bar, the dongle will query some information from the 
device. 

Figure 

Query the information from the device

After all done, the all buttons of the main function part will recover,

and in the device list part will add a new device record. The message

part will show a new device was added, and which node id it is.

6

Summary of Contents for PAU01

Page 1: ...Specifications Operating Voltage DC5V 1A from USB Operating Temperature 10 C 55 C 85 humidity Storage Temperature 30 C 85 C RF Range distance Minimum 40M in door and 100M in outdoor line of sight Frequency Range 868 40MHz 869 85MHz EU 908 40MHz 916 00MHz US 916 00 MHz IL Israel PAU01 IL 920 924MHz Taiwan Korea RF Power 5dBm FCC ID RHHPAU01 Specifications are subject to change and improvement witho...

Page 2: ...is a uzb inf file Insert the dongle to the PC in the first time the PC will issue the driver can t found You can observe the Control Panel System and Security System Hardware Device Manager Click the Device Manager Right Click the Unknown device And select Update Driver Software Click Browse my computer for driver software 2 ...

Page 3: ...Fill the driver file location And click Next Select Install this driver software anyway Wait a while Install OK 3 ...

Page 4: ...u can easily use the Windows Update to install that Windows 7 already install Net Framework in default 2 Start Insert the USB dongle and execute the PhilioZWaveUtil exe to start the application If the application can t find the USB dongle it will show the pop window and click the OK button to close the application Figure 1 USB dongle not found Normally the application will read controller informat...

Page 5: ...e 3 Binding This function tab is for user to maintain the Z Wave network include or remove a device from the network or add dongle to the other network Figure 4 Binding page The binding page has 5 parts 1 Controller Info The information of the controller 2 Main Function Include or exclude the device from the network and also can add the dongle to the other network 3 Controller Function User can ab...

Page 6: ...he include operation please press the Abort button in the controller function part Figure 5 Controller into inclusion mode Now press the learning key on the device usually the Z Wave devices made from Philio press the learning key three times the device will into the learn mode If the controller got that message the UI will show a progress bar the dongle will query some information from the device...

Page 7: ...part will be disabled And the controller will into to the exclusion mode If you want to abort the exclude operation please press the Abort button in the controller function part Figure 8 Controller into exclusion mode Now remove the device from the controller press the learning key three times If the controller got the message the controller will remove it The all buttons of the main function part...

Page 8: ...nd class And the time of receive the report You can see there are two time in this part the second time it the time of now the last number is the discrepancy seconds of these two times 3 Content The content of the report 4 Operation Buttons You can save reload or clear the history report And also can close the Report Form Note When you load the report from the saved file that history report will d...

Page 9: ...options First one is Send Instantly if the device is awake you can check this option after you click the send button the command will send to the device instantly otherwise please don t check it And after you click the send button the application will put the command into the queue wait the device to wake up or got the node information from that device When it happen the application will send out ...

Page 10: ...means the version of that command type 2 means version 2 At the end click the send button to send out the command Some command types will response the report So the Report Form will pop up please refer to the 8 Report Form 6 Consistent Test This page is for test the RF command is send to the device correctly Figure 16 Consistent Test Page You can do some settings by press the settings button Figur...

Page 11: ...provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause ...

Page 12: ...e return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling www philio tech com Philio Technology Corporation 8F No 653 2 Zhongzheng Rd Xinzhuang Dist New Taipei City 24257 Taiwan Warning Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local go...

Reviews: