NO.
Name
Def.
Valid
Description
1
Operation
Mode
All
Bit control.
0
Bit0
: reserve.
0
Bit1
: reserve.
0
Bit2
: reserve.
1
Bit3
: Set temperature unit.
0: Fahrenheit 1: Celsius
0
Bit4
: CH1 overheat notification
0:disable 1:enable
0
Bit5
: CH1 under heat notification
0:disable 1:enable
0
Bit6
: CH2 overheat notification
0:disable 1:enable
0
Bit7
: CH2under heat notification
0:disable 1:enable
2
Custom
Func
All
Bit control.
01
Bit0
、
Bit1
: Set CH1 thermocouple
type
00 → disable
,
01 → K-type
10 → T-type
,
11 → J-type
0
Bit2
: reserve.
00
Bit3
、
Bit4
: Set CH2 thermocouple
type
00 → disable
,
01 → K-type
10 → T-type
,
11 → J-type
0
Bit5
: reserve.
0
Bit6
: reserve.
0
Bit7
: reserve.
NO.
Name
Def.
Valid
Description
3
Auto
Report
Temperat
ure Time
5
0 ~
127
Temperaturn auto report time
0 : disable.
Default is 5. Tick Interval can
setting by configuration No.4.
4
Auto
Report
Tick
Interval
12
0 ~
0xFF
The interval time for auto report
each tick. Setting this configuration
will effect configuration No.3.
Units of one minute.
Caution1:
Setting to 0 means
turn off all auto report function.
Caution2
: The value is unsigned
byte, the range is from 0x00 ~
0xFF.
5
Temperat
ure
Differenti
al Report
0
0 ~
127
The temperature differential to
report.
0 means turn off this function.
The unit is Celsius.
And when the temperature is over
140 degree Fahrenheit, it will
continue report.
6
CH1
Temperat
ure High
threshold
32767 int16 CH1 overheat notification t
hreshold.
7
CH1
Temperat
ure Low
threshold
-32768 int16
CH1 underheat notification
t
hreshold.
8
CH2
32767 int16 CH2 overheat notification t
hreshold.
5