NO.

Name

Def.

Valid 

Description

1

Operation
Mode

All

Bit control.

0

Bit0

: reserve.

0

Bit1

: reserve.

0

Bit2

: reserve.

1

Bit3

: Set temperature unit.

  0: Fahrenheit 1: Celsius

0

Bit4

: CH1 overheat notification 

0:disable 1:enable

0

Bit5

: CH1 under heat notification 

0:disable 1:enable

0

Bit6

: CH2 overheat notification 

0:disable 1:enable

0

Bit7

: CH2under heat notification 

0:disable 1:enable

2

Custom 
Func

All

Bit control.

01

Bit0

Bit1

: Set CH1 thermocouple 

type
00 → disable

01 → K-type

10 → T-type

11 → J-type

0

Bit2

: reserve.

00

Bit3

Bit4

: Set CH2 thermocouple 

type
00 → disable

01 → K-type

10 → T-type

11 → J-type

0

Bit5

: reserve.

0

Bit6

: reserve.

0

Bit7

: reserve.

NO.

Name

Def.

Valid 

Description

3

Auto 
Report 
Temperat
ure Time

5

0 ~

127

Temperaturn auto report time
0 : disable.
Default is 5. Tick Interval can 
setting by configuration No.4.

4

Auto 
Report 
Tick 
Interval

12

0 ~

0xFF

The interval time for auto report 
each tick. Setting this configuration
will effect configuration No.3.
Units of one minute.
Caution1: 
Setting to 0 means 
turn off all auto report function.
Caution2
: The value is unsigned 
byte, the range is from 0x00 ~ 
0xFF.

5

Temperat
ure 
Differenti
al Report

0

0 ~

127

The temperature differential to 
report.
0 means turn off this function. 
The unit is Celsius.
And when the temperature is over 
140 degree Fahrenheit, it will 
continue report.

6

CH1 
Temperat
ure   High
threshold

32767 int16 CH1 overheat notification t

hreshold.

7

CH1 
Temperat
ure   Low 
threshold

-32768 int16

CH1 underheat notification 
t

hreshold.

8

CH2 

32767 int16 CH2 overheat notification t

hreshold.

5

Summary of Contents for PAT14

Page 1: ...work act as repeaters to increase the stability and reliability of the Z Wave network The product is supported with Over the Air OTA feature for firmware upgrade Specification Rated DC5 24V 6mA RF distance Min 40M indoor 100M outdoor line of sight RF Frequency 868 40 MHz 869 85 MHz EU 908 40 MHz 916 00 MHz US 920 9MHz 921 7MHz 923 1MHz TW SG Thai KR RF Maximum Power 10dBm Peak 10dBm Average Dimens...

Page 2: ...For Instruction to http www philio tech com Add to Remove from Z WaveTM Network There is a button with LED indicator in front of PAT14 It is used to dim on off the light and carry out the inclusion exclusion reset or association of PAT14 from Z wave controller When the fist power one the LED indicator flashes once per second for 30 seconds With the SmartStart function PAT14 will be automatically i...

Page 3: ...tions provided by the controller manufacturer 2 Press the button on PAT14 three times within 3 sec onds to enter exclusion mode 3 Node ID will be excluded Reset 1 Press the button of PAT14 four times within 3 sec onds and hold the last press until the LED light turns off Adding a node ID allocated by Z Wave Controller means inclusion Removing a node ID allocated by Z Wave Controller means exclusio...

Page 4: ... status Temperature report Every 1 hours report once in default It could be changed by setting the configuration NO 5 Notice The configuration NO 5 could be setting to zero to disable the auto report And the configuration NO 6 could change the tick interval the default value is 12 if setting to 1 that means the minimum auto report interval will be one minute And please notice if setting this value...

Page 5: ...uto Report Temperat ure Time 5 0 127 Temperaturn auto report time 0 disable Default is 5 Tick Interval can setting by configuration No 4 4 Auto Report Tick Interval 12 0 0xFF The interval time for auto report each tick Setting this configuration will effect configuration No 3 Units of one minute Caution1 Setting to 0 means turn off all auto report function Caution2 The value is unsigned byte the r...

Page 6: ...y Class CAUTION Risk of explosion if battery is replaced by an incorrect type Dispose of used battery according to the instructions Choosing a Suitable Location 1 The suitable ambient temperature for the module device is 10 C 40 C 2 Do NOT place the module device direct under sunlight in a humid place or in any location where they may contact moisture dirt dust 3 Do NOT place the module device whe...

Page 7: ... to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modi...

Reviews: