background image

 

1.  Put  the  in  wall  switch  into  a  wall  box  and  connect  the  AC  power  wire  L,  N  to 

PAN33 connector L, N.

 

2.  Connect the wall switch to the PAN33 as Fig1.

 

3.  There  are  3  mode  PAN33  can  be  configured  to  match  different  kind  of  wall 

switch,  please  refer  to  3-1 

External  switch  mode

  which  described  in  next 

section of this user manual 

 

4.  If  Edge-Toggle  mode  has  been  set,  and  the  S1/S2  is  connect  to  normal 

bi-stable  switch,  every  time  when  change  the  state  of  the  wall  switch  will  also 
swap the state of Relay1.

 

 

Programming

 

 

1.    Basic Command Class / Binary Switch Command Class

 

The Switch will respond to BASIC and BINARY commands that are part of the 
Z-Wave system.

 

 

1-1 BASIC_GET / BINARY_SWITCH_GET 
PAN33 will report ON when relay 1 is ON, or report OFF when relay1 is OFF.

 

 

       

 

Basic Get Command: [Command Class Basic, Basic Get]

 

Basic Report Command:

 

Report OFF: [Command Class Basic, Basic Report, Value = 0(0x00)]

 

Report ON:[Command Class Basic, Basic Report, Value = 255(0xFF)]

 

 

Binary  Switch  Get  Command:[Command  Class  Switch  Binary,  Switch  Binary 
Get]

 

Binary Switch Report Command:

 

Report OFF:[Command Class Switch Binary, Switch Binary Report, Value 
=0(0x00)]

 

Report ON:[Command Class Switch Binary, Switch Binary Report, Value = 
255(0xFF)]

 

 

1-2 BASIC_SET / SWITCH_BINARY_SET

 

PAN33  will  turn  on  or  off  upon  receipt  of  the  following  commands  from  a 
Z-Wave Controller.

 

 

[Command  Class  Basic,  Basic  Set,  Value  =  1~99,  255(0xFF)]:  both  the  load 
attached to the Switch turns on.

 

[Command Class Basic, Basic Set, Value = 0(0x00)]: both the load attached to 
the Switch turns off.

 

[Command  Class  Switch  Binary,  Switch  Binary  Set,  Value  =  1~99, 
255(0xFF)]
: both the load attached to the Switch turns on.

 

[Command  Class  Switch  Binary,  Switch  Binary  Set,  Value  =  0(0x00)]:  both 
the load attached to the Switch turns off.

 

 

1.  Z-Wave’s Groups (Association Command Class Version 2)

 

The Switch can be set to send reports to the associated Z-Wave devices.    It 
supports one groups and every group has five nodes support. Group1 is called 
Lifeline which support SWITCH_BINARY_REPORT

NOTIFICATION_REPORT

 

INDICATOR_REPORT and DEVICE_RESET_LOCALLY_NOTIFICATION.

 

 

2-1 Auto report to Grouping 1(Maximum Node 5)

 

2-1-1 On/Off Event Report 

 

      When “on” or “off” state has been changed (ex. Press S1 or S2 or include on/off 

button), it will send Binary Switch Report to the nodes of Group1. 

 

     

 

          Binary Switch Report

 

ON:[Command Class Switch Binary, Switch Binary Report, Value 

=255(0xFF)]

 

OFF:[Command Class Switch Binary, Switch Binary Report, Value =0(0x00)]

 

 

2-1-2 Overload Notification report command

 

      When PAN33 detect the overload, it will send Notification Report to Group1.   

 

 
      The content of Notification Report

 

Notification report command:[Command Class Notification, Notification 

Report, Notification Type = 0x08, Event state = 0x08]

 

 

2.  Z-Wave’s Configuration

 

Configura

tion

 

Paramete

r

 

Function

 

Size

 

(Byte)

 

Value

 

Unit

 

Default

 

Description

 

1

 

External 
switch mode

 

1

 

1-3

 

 

1

 

1

Edge mode

 

2

Pulse mode

 

3

Edge-Toggle           

mode

 

2

 

Restore switch 
state mode

 

1

 

0-2

 

 

1

 

0 : Switch off

 

1 : Last switch 

Summary of Contents for PAN33

Page 1: ... informed about the standards and technical requirements of the appliance and its proper installation Check your local codes as they apply to your situation If the house wiring is of aluminum consult with an electrician about proper wiring methods Before proceeding with the installation TURN OFF THE POWER TO THE LIGHTING CIRCUIT AT THE CIRCUIT BREAKER OR FUSE BOX TO AVOID ELECTRICAL SHOCK Specific...

Page 2: ...3 Connect external Switch S1 and S2 to L Fig 1 Assembling and wiring For Instruction to http www philio tech com DANGER Danger of electrocution All works on the device may be performed only by a qualified and licensed electrician Observe national regulations Any works introducing changes into the configuration must be always performed with disconnected voltage Choosing a Suitable Location 1 Do not...

Page 3: ...be used for inclusion or exclusion for 3 minutes after power up Pressing Include button of PAN33 three times within 2 seconds will enter exclusion mode Node ID has been excluded 2s On 2s Off No node ID Reset Pressing Include button of PAN33 three times within 2 seconds will enter inclusion mode One press one flash Within 1 second press Include button of PAN33 again for 5 seconds IDs are excluded 2...

Page 4: ... 0xFF both the load attached to the Switch turns on Command Class Basic Basic Set Value 0 0x00 both the load attached to the Switch turns off Command Class Switch Binary Switch Binary Set Value 1 99 255 0xFF both the load attached to the Switch turns on Command Class Switch Binary Switch Binary Set Value 0 0x00 both the load attached to the Switch turns off 1 Z Wave s Groups Association Command Cl...

Page 5: ...H STATE SWITCH ON The default setting is LAST SWITCH STATE 3 3 Manual On Off Mode The On Off function of S1 S2 and learn switch can be disabled or enabled by this parameter default value is Enable But the learning operation won t be affected When manual On Off function is disabled the RF command can only switch On but not Off This is useful function for keeping the device in switch on state 3 4 LE...

Page 6: ...ted and found to comply with the limit s for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio ...

Page 7: ...7 警語 警語 警語 警語 取得審驗證明之低功率射頻器材 非經核准 公司 商號或使用者均不得擅自變更 頻率 加大功率或變更原設計之特性及功能 低功率射頻器材之使用不得影響飛航安全及干擾合法通信 經發現有干擾現象時 應 立即停用 並改善至無干擾時方得繼續使用 前述合法通信 指依電信管理法規定作業之無線電通信 低功率射頻器材須忍受合法 通信或工業 科學及醫療用電波輻射性電機設備之干擾 ...

Reviews: