background image

 

Supervision

 

1

 

None

 

Transport Service

 

2

 

None

 

Association

 

2

 

Highest granted Security Class

 

Association Group Information

 

3

 

Highest granted Security Class

 

Basic

 

2

 

Highest granted Security Class

 

Binary Switch

 

2

 

Highest granted Security Class

 

Configuration

 

4

 

Highest granted Security Class

 

Device Reset Locally

 

1

 

Highest granted Security Class

 

Firmware Update Meta Data

 

5

 

Highest granted Security Class

 

Indicator

 

3

 

Highest granted Security Class

 

Manufacturer Specific

 

2

 

Highest granted Security Class

 

Multi Channel Association

 

3

 

Highest granted Security Class

 

Notification

 

8

 

Highest granted Security Class

 

Powerlevel

 

1

 

Highest granted Security Class

 

Version

 

3

 

Highest granted Security Class

 

 

Disposal   

 

This marking indicates that this product should not be disposed with 
other household wastes throughout the EU. To prevent possible harm to 
the environment or human health from uncontrolled waste disposal, 
recycle it responsibly to promote the sustainable reuse of material 
resources. To return your used device, please use the return and 
collection systems or contact the retailer where the product was 
purchased. They can take this product for environmental safe recycling.

 

Philio Technology Corporation

 

8F.,No.653-2,Zhongzheng Rd., Xinzhuang Dist., New Taipei City 24257,Taiwan(R.O.C)   

 

www.philio-tech.com

 

 

FCC Interference Statement

 

This equipment has been tested and found to comply with the limit’s for a Class B digital 

device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide 

reasonable protection against harmful interference in a residential installation. This 

equipment generates, uses and can radiate radio frequency energy and, if not installed and 

used in accordance with the instructions, may cause harmful interference to radio 

communications. However, there is no guarantee that interference will not occur in a 

particular installation. If this equipment does cause harmful interference to radio or television 

reception, which can be determined by turning the equipment off and on, the user is 

encouraged to try to correct the interference by one of the following measures:

 

• Reorient or relocate the receiving antenna.

 

• Increase the separation between the equipment and receiver.

 

• Connect the equipment into an outlet on a circuit different from

 

that to which the receiver is connected.

 

• Consult the dealer or an experienced radio/TV technician for help.

 

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two 

conditions:

 

(1) This device may not cause harmful interference, and

 

(2) This device must accept any interference received, including interference that may cause 

undesired operation.

 

FCC Caution: Any changes or modifications not expressly approved by the party responsible 

for compliance could void the user's authority to operate this equipment.

 

This transmitter must not be co-located or operating in conjunction 

with any other antenna 

or transmitter.

 

 

 

 

Summary of Contents for PAN33

Page 1: ... informed about the standards and technical requirements of the appliance and its proper installation Check your local codes as they apply to your situation If the house wiring is of aluminum consult with an electrician about proper wiring methods Before proceeding with the installation TURN OFF THE POWER TO THE LIGHTING CIRCUIT AT THE CIRCUIT BREAKER OR FUSE BOX TO AVOID ELECTRICAL SHOCK Specific...

Page 2: ...3 Connect external Switch S1 and S2 to L Fig 1 Assembling and wiring For Instruction to http www philio tech com DANGER Danger of electrocution All works on the device may be performed only by a qualified and licensed electrician Observe national regulations Any works introducing changes into the configuration must be always performed with disconnected voltage Choosing a Suitable Location 1 Do not...

Page 3: ...be used for inclusion or exclusion for 3 minutes after power up Pressing Include button of PAN33 three times within 2 seconds will enter exclusion mode Node ID has been excluded 2s On 2s Off No node ID Reset Pressing Include button of PAN33 three times within 2 seconds will enter inclusion mode One press one flash Within 1 second press Include button of PAN33 again for 5 seconds IDs are excluded 2...

Page 4: ... 0xFF both the load attached to the Switch turns on Command Class Basic Basic Set Value 0 0x00 both the load attached to the Switch turns off Command Class Switch Binary Switch Binary Set Value 1 99 255 0xFF both the load attached to the Switch turns on Command Class Switch Binary Switch Binary Set Value 0 0x00 both the load attached to the Switch turns off 1 Z Wave s Groups Association Command Cl...

Page 5: ...H STATE SWITCH ON The default setting is LAST SWITCH STATE 3 3 Manual On Off Mode The On Off function of S1 S2 and learn switch can be disabled or enabled by this parameter default value is Enable But the learning operation won t be affected When manual On Off function is disabled the RF command can only switch On but not Off This is useful function for keeping the device in switch on state 3 4 LE...

Page 6: ...ted and found to comply with the limit s for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio ...

Page 7: ...7 警語 警語 警語 警語 取得審驗證明之低功率射頻器材 非經核准 公司 商號或使用者均不得擅自變更 頻率 加大功率或變更原設計之特性及功能 低功率射頻器材之使用不得影響飛航安全及干擾合法通信 經發現有干擾現象時 應 立即停用 並改善至無干擾時方得繼續使用 前述合法通信 指依電信管理法規定作業之無線電通信 低功率射頻器材須忍受合法 通信或工業 科學及醫療用電波輻射性電機設備之干擾 ...

Reviews: