Adding to Z-Wave

TM

 Network

 

In the front casing, there is an on/off button with LED indicator below which is used 
to  toggle  switch  on  and  off.  The  table  below  lists  an  operation  summary  of  basic 
Z-Wave  functions.  Please  refer  to  the  instructions  for  your  Z-Wave

TM

  Certificated 

Primary  Controller  to  access  the  Setup  function,  and  to  include/exclude/reset 
devices

 

 

Function

 

Description

 

LED Indication

 

No node ID

 

The Z-Wave Controller does not allocate 
a node ID to the Switch.

 

2-second on, 2-second off

 

Add

 

(Inclusion)

 

 
 
 

Have Z-Wave Controller entered 
inclusion mode.

 

One press one flash

 

 To support handling of the 

 

device when already installed 

 

the external switch can be 

 

used for inclusion or exclusion 

 

for 3 minutes after power up.

 

Pressing Include button of PAN33 three 
times within 2 seconds will enter 
inclusion mode.

 

 

SmartStart

 

 
 
 
 
 

1. To initiate the SmartSart process, 

please type in the first five digits of 
DSK string or scan the QR code. The 
QR Code can be found on PAN33 or 
in the box. Ex:

 

DSK:    18112-24021-58001-62259-

 

57092- 27453-08187-47408

 

2. PAN33 is supported with SmartStart, it 

can be added to Z-Wave™ network by 
scanning the Z-Wave™ QR code on 
the product.

 

3. Without further actions, PAN33 will be 

automatically included in a certified 
Z-Wave™ Controller with SmartStart 
inclusion ability in 10 minutes after it 
turned on.

 

 

Remove

 

(Exclusion)

 

Have Z-Wave Controller entered 
exclusion mode.

 

One press one flash

 

 To support handling of the 

 

device when already installed 

 

the external switch can be 

 

used for inclusion or exclusion 

 

for 3 minutes after power up. 

 

Pressing Include button of PAN33 three 
times within 2 seconds will enter 
exclusion mode.

 

Node ID has been excluded.

 

2s On, 2s Off (No node ID)

 

Reset

 

Pressing Include button of PAN33 three 
times within 2 seconds will enter 
inclusion mode.

 

One press one flash

 

Within 1 second, press Include button of 
PAN33 again for 5 seconds.

 

IDs are excluded.

 

2s On, 2s Off (No node ID)

 

Adding

 a node ID allocated by Z-Wave Controller means inclusion.   

Removing

 a node

 

ID allocated by Z-Wave Controller means exclusion.

 

Failed or success in including/excluding the node ID can be viewed from the Z-Wave 

Controller. 

 

    Sometimes people are not easy to execute exclusion or inclusion especially when PAN33 

 

already installed in a wall box. To solve this issue, PAN33 support a special feature that can 

 

use S1 or S2 to execute “exclusion, inclusion, Reset or Association” at the first 3 minutes when 

 

first time connect to main power. 

 

 

LED Indication

 

There is a LED for identify function in the front case. 

PAN33

 support the indicator 

ID 0x50 (Identify) and Properties ID 0x03, 0x04 and 0x05.

 

To distinguish what mode the switch is in, view from the LED for identification.

 

 

State Type

 

LED Indication

 

Normal

 

When PAN33 switch On the LED will lights up, when PAN33 switch 
Off the LED will lights off.

 

No node ID

 

Under normal operation, when the Switch has not been allocated a 
node ID, the LED flashes on and off alternately at 2-second intervals. 

 

Overload

 

When overload state occurs, the Switch is disabled of which LED

 

flashes on and off alternately at 0.2 second intervals. Overload

 

state can be cleared by disconnect and reconnect the Switch to

 

the main power.

 

 
 
Installation

 

 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for PAN33

Page 1: ... informed about the standards and technical requirements of the appliance and its proper installation Check your local codes as they apply to your situation If the house wiring is of aluminum consult with an electrician about proper wiring methods Before proceeding with the installation TURN OFF THE POWER TO THE LIGHTING CIRCUIT AT THE CIRCUIT BREAKER OR FUSE BOX TO AVOID ELECTRICAL SHOCK Specific...

Page 2: ...3 Connect external Switch S1 and S2 to L Fig 1 Assembling and wiring For Instruction to http www philio tech com DANGER Danger of electrocution All works on the device may be performed only by a qualified and licensed electrician Observe national regulations Any works introducing changes into the configuration must be always performed with disconnected voltage Choosing a Suitable Location 1 Do not...

Page 3: ...be used for inclusion or exclusion for 3 minutes after power up Pressing Include button of PAN33 three times within 2 seconds will enter exclusion mode Node ID has been excluded 2s On 2s Off No node ID Reset Pressing Include button of PAN33 three times within 2 seconds will enter inclusion mode One press one flash Within 1 second press Include button of PAN33 again for 5 seconds IDs are excluded 2...

Page 4: ... 0xFF both the load attached to the Switch turns on Command Class Basic Basic Set Value 0 0x00 both the load attached to the Switch turns off Command Class Switch Binary Switch Binary Set Value 1 99 255 0xFF both the load attached to the Switch turns on Command Class Switch Binary Switch Binary Set Value 0 0x00 both the load attached to the Switch turns off 1 Z Wave s Groups Association Command Cl...

Page 5: ...H STATE SWITCH ON The default setting is LAST SWITCH STATE 3 3 Manual On Off Mode The On Off function of S1 S2 and learn switch can be disabled or enabled by this parameter default value is Enable But the learning operation won t be affected When manual On Off function is disabled the RF command can only switch On but not Off This is useful function for keeping the device in switch on state 3 4 LE...

Page 6: ...ted and found to comply with the limit s for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio ...

Page 7: ...7 警語 警語 警語 警語 取得審驗證明之低功率射頻器材 非經核准 公司 商號或使用者均不得擅自變更 頻率 加大功率或變更原設計之特性及功能 低功率射頻器材之使用不得影響飛航安全及干擾合法通信 經發現有干擾現象時 應 立即停用 並改善至無干擾時方得繼續使用 前述合法通信 指依電信管理法規定作業之無線電通信 低功率射頻器材須忍受合法 通信或工業 科學及醫療用電波輻射性電機設備之干擾 ...

Reviews: