PAN08-1A/-2A/-3A  Roller shutter controller

     

 

Fig 1. Assembling 

The in-wall Roller Shutter Controller is designed to switch rise/lower roller shutter 

connected to its terminals using radio waves, controllers and a push button directly 

connected to this Roller Controller.

This in-wall Roller Shutter Controller is a transceiver which is a Z-Wave Plus

TM

 

enabled device and is fully compatible with any Z-Wave

TM

 enabled network. Slim 

design let the Controller can easily hide itself into the wall box and that will be good 

for the house decoration. 

The new smart relay calibration technology can reduce the inrush current caused by 

the load and let the module work perfectly with many kind of Roller Shutter.  

This in-wall Roller Shutter Controller is able to detect position of the Shutter by using

the patterned power measuring method, so it can be remote controlled not only fully

up   or   down   ,   but   also   can   be   adjusted   to   ex.   30%   or   50%.  And   when   manual

controlled by push button, the controller also can memorize the position and send the

new shutter position to its controller (ex. IP-Gateway).

Adding to Z-Wave

TM

 Network

In the front casing, there is an include button with LED indicator below which is used

to carry out inclusion, exclusion, reset or association. When first power is applied, its

LED flashes on and off alternately and repeatedly at 0.5 second intervals. It implies

that it has not been assigned a node ID and start auto inclusion. 

Auto Inclusion

The function of auto inclusion will be executed as long as the PAN08 does not have 

Node ID and just connect the PAN08 to main power.

1

Summary of Contents for PAN08-1A

Page 1: ...er Shutter This in wall Roller Shutter Controller is able to detect position of the Shutter by using the patterned power measuring method so it can be remote controlled not only fully up or down but also can be adjusted to ex 30 or 50 And when manual controlled by push button the controller also can memorize the position and send the new shutter position to its controller ex IP Gateway Adding to Z...

Page 2: ...ontroller into exclusion mode by following the instructions provided by the controller manufacturer One press one flash LED 2 Pressing Include button three times within 2 seconds will enter exclusion mode Node ID has been excluded LED 0 5s On 0 5s Off En ter auto inclusion Reset 1 Pressing Include button three times within 2 seconds will enter inclusion mode Use this procedure only in the event th...

Page 3: ...n learning mode LED flashes on and off alternately and repeatedly at 0 5 second intervals Overload When overload state occurs the PAN08 is disabled and LED flashes on and off alternately at 0 2 second intervals PAN08 will send alarm_type 8 alarm_Level 0xFF to Group1 Overload state can be cleared by disconnect and reconnect the PAN08 to the main power Choosing a Suitable Location 1 Do not locate th...

Page 4: ...ter simply press the external switch S1 or S2 The detail is described in 7 5 8 PAN08 built in meter function and can read the Watt KWh V Voltage I Current PF Power Factor of the load by using Z Wave command class user can set a threshold current to get the warning caused by abnormal operation 9 PAN08 have overload protection function and can help to prevent short circuit caused by load Programming...

Page 5: ... Command Command Class Binary Switch Binary Switch Get Binary Switch Report Command Command Class Binary Switch Binary Switch Report Value 0x00 BOT TOM Command Class Binary Switch Binary Switch Report Value 0xFE UN KNOWN Command Class Binary Switch Binary Switch Report Value 0xFF TOP 2 2 BINARY_SWITCH_SET PAN08 can only accept Binary Switch Set Command which value is either 0x00 Bottom or Top 0xFF...

Page 6: ...Command Command Class Multilevel Switch Multilevel Switch Report Value 0x00 BOTTOM Command Class Multilevel Switch Multilevel Switch Report Value 0x01 0x62 Between BOTTOM and TOP Command Class Multilevel Switch Multilevel Switch Report Value 0x63 0xFF TOP 3 3 MULTILEVEL SWITCH START LEVEL CHANGE This is the command which user can move the shutter up to the top or down to the bottom Command Class M...

Page 7: ...de bit 0 Level 0 99 or 255 The current setting of PAN08 will not be override Command Class Scene Actuator Configuration Scene Actuator Configuration Set Scene ID 1 255 Override bit 1 Level 0 99 or 255 The Level value in this Command is associated to the Scene ID 5 2 Scene Actuator Configuration Get Command Command Class Scene Actuator Configuration Scene Actuator Configuration Get Scene ID 1 255 C...

Page 8: ...Example Meter Value 1 0x00 W Meter Value 2 0x00 W Meter Value 3 0x03 W Meter Value 4 0xEA W Meter W Meter Value 3 256 Meter Value 4 100 2W 6 2 2 Accumulated Power Consumption KW h When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Meter Meter Get Scale 0x00 KW h Meter Report Command Command Class Meter Meter Report Rate Type 0x01 ...

Page 9: ...current Meter Value 1 256 Meter Value 2 2 89 A 6 2 5 load power factor PF When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Meter Meter Get Scale 0x06 PF Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x06 Size 1 Bytes Meter Value PF Example Scale 0x06 PF Precision 2 Size 1 ...

Page 10: ...erload Command_Class_Alarm Alarm_Report Alarm Type 0x08 Alarm Level 0x00 Normal When in Two Push Button switch type S1 or S2 are closed and not released to open and PAN08 receive any control moving command from Z Wave RF it will report alarm to Group1 Command_Class_Alarm Alarm_Report Alarm Type 0x01 Alarm Level 0xFF S1 or S2 close to L Command_Class_Alarm Alarm_Report Alarm Type 0x01 Alarm Level 0...

Page 11: ...lue is 1KWh and default value is 10000 kWh 7 5 External switch type 7 5 1 One Push Button When the configuration setting is One Push Button only S1 input will be valid The control moving commands can be accepted in this switch type while the shutter is moving In this switch type the inclusion exclusion reset association function can also be fulfilled by pressing S1 just like the operation of inclu...

Page 12: ... S2 7 6 Level Report mode Mode 1 In 5 seconds period after controlled by a moving command it will report the destination level when received request command Out of the 5 seconds period it will report the actual level of the shutter when received request command Mode 2 Whenever the shutter move pass a 10 percent level it will auto report the level to Group 1 node 8 Command Classes The Switch suppor...

Page 13: ... this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this...

Page 14: ... connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly a...