2-2-6 load power factor (PF)
When receiving Meter Get Command, it will report Meter Report Command to the
node.
Meter Get Command:
[Command Class Meter, Meter Get, Scale =0x06(PF)]
Meter Report Command:
[Command Class Meter
,
Meter Report
,
Rate Type = 0x01
,
Meter Type = 0x01
,
Precision = 2
,
Scale = 0x06
,
Size = 1 Bytes
,
Meter Value(PF)]
Example:
Scale = 0x06 (PF)
Precision = 2
Size = 1 (1 Byte of PF)
Meter Value 1 = 0x63(PF) (It means that the load power factor is 0.99)
3. Z-Wave’s Configuration
Configuration
Parameter
Function
Size
(Byte)
Value
Unit
Default
Description
1
Watt Meter
Report Period
2
0x00-
0x7FFF
5s
720
0: Disable Watt Report
1~32767 : 5s~ 45h
2
KWH Meter
Report Period
2
0x00-
0x7FFF
10min
6
0:Disable KWh Report
1~32767 : 10min~
227days
3
Threshold of
current for Load
caution
2
10-1300
0.01A
1300
1300*0.01A = 13A
4
Threshold of
KWh for Load
caution
2
1-10000
1KWh
10000
10000*1KWh = 10000
KWh
5
Restore switch
state mode
1
0-2
1
0 : Switch off
1 : Last switch state
2 : Switch on
6
Mode of Switch
Off function
1
0-1
1
0 : Disable
1 : Enable
7
LED indication
mode
1
1-3
1
1 : Show switch state
2 : Show night mode
3 : One flash mode
8
Auto off timer
2
0-0x7FFF
1s
0
0 : Disable auto off
function
1-0x7FFF : 1s ~
32767s
9
RF off
command mode
1
0-3
0
0 : Switch off
1 : Ignore
2 : Switch toggle
3 : Switch on
11
Manual Switch
Report mode
1
0-1
1
0 : Disable
1 : Enable
12
Auto Report
after Reset
1
0-1
0
0 : Disable
1 : Enable
13
Adjustable
Overload
2
450-1450
0.01A
1450
1450*0.01A=14.5A
3-1
Watt
Meter Report Period:
If the setting is configured for 1hour (set value =720), PAN16 will report its instant
power consumption to Group1 node every 1 hour. The maximum interval to report
its instant power consumption is 45 hours (5s*32767/3600=45hr). When the
setting is 0, PAN16 will disable Watt auto report function. The default value is 720.
3-2 KWH Meter Report Period:
If the setting is configured for 1hour (set value =6), PAN16 will report its
Accumulated Power Consumption (KWh) to Group1 node every 1 hour. The
maximum interval to report its Accumulated Power Consumption (KWh) is 227.55
days (10min*32767/1440=227.55 days). When the setting is 0, PAN16 will disable
KWH auto report function. The default value is 6.
3-3 Threshold of current for Load Caution
This is a warning when the current of load over the preset threshold value, if the
setting value is 1300, when the load current of Relay1 over this value, PAN16
will send current meter report to warn the Group1 node, the range of the setting
value is from 10 to 1300,and the default value is 1300.
3-4 Threshold of KWh for Load Caution
This is a warning when the KWh of load over the preset threshold value, If the
setting value is 10000, when the Accumulated Power Consumption of Relay1 over
this value, PAN16 will send KWH meter report to warn the Group1 node,
minimum value is 1KWh and default value is 10000 kWh.
3-5 Restore switch state mode :
Whenever the AC power return from lost, PAN16 will restore the switch state which
could be SWITCH OFF
、
LAST SWITCH STATE
、
SWITCH ON. The default setting
is LAST SWITCH STATE.