Troubleshooting

 

                                 

 

Symptom

 

Cause of Failure

 

Recommendation

 

The Switch not working and 
LED off

 

1.

 

The Switch is not 
plugged into the 

electrical outlet 

properly

 

2.

 

The Switch break down

 

1.

 

Check power connections

 

2. Don’t open up the Switch and send it for 

repair.

 

The Switch LED 
illuminating, but cannot 

control the ON/OFF

 

Switch of the load attached

 

1.Check if the load 

plugged into the Switch 

has its own ON/OFF 

switch

 

2. The switch is protected

 

1. Set the ON/OFF switch of the load 

attached to ON

 

2. Unprotected the switch or follow the 

instruction of protection.

 

The Switch LED 
illuminating, but the 

Detector cannot control

 

the Switch

 

1. Not carry out 

association

 

2. Same frequency 

interference

 

1. Carry out association

 

2. Wait for a while to re-try

 

LED keep flashing, but 

cannot control

 

Overload occurs

 

Remove the load attached or check max. 

load cannot exceed 13A (Resistive load)

 

 

Specification

 

 

Operating Voltage

 

220V~240V / 50Hz for EU Type

 

Operating Voltage

 

100V~120V / 50Hz/60Hz for US Type

 

Maximum Load (Ampere)

 

13A (Resistive load) 

 

PAN16-1; PAN16-2; PAN16-3

 

Maximum Load (Ampere)

 

10A (Resistive load) 

 

PAN16-4

 

(Switzerland)

 

Socket Type:

 

Germany type: PAN16-1

 

France type: PAN16-2

 

UK type: PAN16-3

 

Switzerland type: PAN16-4

 

Range

 

Minimum 40 m in door 100m outdoor line of sight

 

Operating Temperature

 

0°C ~ 40°C

 

Frequency Range

 

868.40MHz & 869.85MHz/ EU (PAN16-1/-2/-3/-4); 

 

RF Maximum Power

 

+5dBm

 

** Specifications are subject to change and improvement without notice.                           

 

 
           

 

 

 

       

 

 

 

Warning:

 

1.Plug out to disconnect from power supply; Do not plug in line. 

 

2. Do not exceed the max rating.

 

Warnung:

 

1.Trennen Sie das Gerät von der Stromzuführung. Verwenden Sie das Gerät 

nicht mit einem DIP Schalter. 

 

2. Achten Sie darauf, dass die maximale Spannung niemals überschritten wird.

 

Warnung:

 

für    zwischenstecker:

 

nicht hintereinander stecken

 

 
 
 
 
 
 

Summary of Contents for PAN16

Page 1: ...Off button with LED indicator which is used to toggle switch on and off or carry out inclusion exclusion reset or association When first power is applied its LED flashes on and off alternately and repeatedly at 0 5 second intervals It implies that it has not been assigned a node ID and start auto inclusion Auto Inclusion The function of auto inclusion will be executed as long as the switch does no...

Page 2: ...ternately at 2 second intervals By pressing On Off button it will stop flashing temporarily Learning When PAN16 is in learning mode LED flashes on and off alternately and repeatedly at 0 5 second intervals Overload When overload state occurs the Switch is disabled of which LED flashes on and off alternately at 0 2 second intervals Overload state can be cleared by unplugging and reconnecting the Sw...

Page 3: ...e Switch will report its latest status to Z Wave Controller Grouping 1 includes SWITCH_BINARY_REPORT METER_REPORT ALARM_REPORT 2 1 Auto report to Grouping 1 Maximum Node 1 2 1 1 On Off Event Report When on or off state has been changed it will send Binary Switch Report to the node of Grouping 1 Binary Switch Report ON Command Class Switch Binary Switch Binary Report Value 255 0xFF OFF Command Clas...

Page 4: ...learing accumulated power consumption Whenever re start counting the accumulated power consumption is needed you can use Meter Reset Command to clear it Meter Reset Command Command Class Meter Meter Reset 2 2 4 AC load Voltage V When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x04 V Meter Report Command Command ...

Page 5: ... 0 01A 14 5A 3 1 Watt Meter Report Period If the setting is configured for 1hour set value 720 PAN16 will report its instant power consumption to Group1 node every 1 hour The maximum interval to report its instant power consumption is 45 hours 5s 32767 3600 45hr When the setting is 0 PAN16 will disable Watt auto report function The default value is 720 3 2 KWH Meter Report Period If the setting is...

Page 6: ...enever PAN16 is repowered it will check this parameter for if sending a BINARY_SWITCH_ REPORT to the node of group1 or not The default setting is Disable the function 3 12 Adjustable Overload The overload current can be adjustable from 4 5A to 14 5A The default value is 1450 for 14 5A 1450 0 01A 14 5A 4 Protection Command Classes PAN16 supports Protection Command Class version 2 it can protect the...

Page 7: ...1 France type PAN16 2 UK type PAN16 3 Switzerland type PAN16 4 Note Please make sure that the intensity of the plug of the electrical device must be 16A and have same head as the enclosed plug before inserting to the socket ...

Page 8: ...oad occurs Remove the load attached or check max load cannot exceed 13A Resistive load Specification Operating Voltage 220V 240V 50Hz for EU Type Operating Voltage 100V 120V 50Hz 60Hz for US Type Maximum Load Ampere 13A Resistive load PAN16 1 PAN16 2 PAN16 3 Maximum Load Ampere 10A Resistive load PAN16 4 Switzerland Socket Type Germany type PAN16 1 France type PAN16 2 UK type PAN16 3 Switzerland t...

Page 9: ...ccordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the follow...

Reviews: