Basic Get Command: 

[Command Class Basic, Basic Get]

 

Basic Report Command:

 

Report OFF: 

[Command Class Basic, Basic Report, Value = 0(0x00)]

 

Report ON:

[Command Class Basic, Basic Report, Value = 255(0xFF)]

 

 

Binary Switch Get Command:

[Command Class Switch Binary, Switch Binary 

Get]

 

Binary Switch Report Command:

 

Report OFF:

[Command Class Switch Binary, Switch Binary Report, Value 

=0(0x00)]

 

Report ON:

[Command Class Switch Binary, Switch Binary Report, Value = 

255(0xFF)]

 

 

1-2 BASIC_SET / SWITCH_BINARY_SET

 

        Upon  receipt  of  the  following  commands  from  a  Z-Wave  Controller,  the  load 

attached to the Switch will turn on or off.

 

 

[Command  Class  Basic,  Basic  Set,  Value  =  1~99,255(0xFF)]

:  the  load 

attached to the Switch turns on.

 

[Command Class Basic, Basic Set, Value = 0(0x00)]

: the load attached to the 

Switch turns off.

 

[Command  Class  Switch  Binary,  Switch  Binary  Set,  Value  =  1~99, 
(255)0xFF]

: the load attached to the Switch turns on.

 

[Command Class Switch Binary, Switch Binary Set, Value = 0(0x00)]

: the load 

attached to the Switch turns off.

 

 

2.  Z-Wave’s Groups (Association Command Class Version 2)

 

 
The  Switch  can  be  set  to  send  reports  to  associated  Z-Wave  devices.    It  supports 
one association group with one node support for Grouping 1. For group 1, the Switch 
will report its latest status to Z-Wave Controller. 

 

 
Grouping 1 includes, SWITCH_BINARY_REPORT, METER_REPORT, 
ALARM_REPORT.

 

 
 

2-1 Auto report to Grouping 1 (Maximum Node 1)

 

 
2-1-1 On/Off Event Report 

 

      When “on” or “off ” state has been changed, it will send Binary Switch Report to the 

node of Grouping 1. 

 

     

 

Binary Switch Report

 

 

ON:

[Command Class Switch Binary, Switch Binary Report, Value 

=255(0xFF)]

 

OFF:

[Command Class Switch Binary, Switch Binary Report, Value =0(0x00)]

 

 

2-1-2 Instant Power Consumption vary over 5% report

 

 
When the power consumption of load vary over 5%, it will send Meter report to the 

nodes of Grouping 1.

 

 

Meter Report Command: 

 

[Command Class Meter

Meter Report

Rate Type = 0x01

Meter Type = 0x01

Precision = 1

Scale = 0x02

Size = 4

Meter Value(W) ]

 

 

2-1-3 Overload alarm report

 

When PAN16 detects the current is more than 14.5A, it will send Alarm Report to 
Group 1 node. 

 

The content of Alarm Report 

 

Alarm report command:

 

[Command_Class_Alarm,  Alarm_Report,  Alarm  Type  =  0x08,  Alarm  Level  = 
0xFF]

 

 

2-2 Response to Meter Get Command

 

      The  Switch  will  report  its  (1)  instant  Power  Consumption  (Watt)    or  (2) 

accumulated power consumption(KWH) or (3)

 

AC load Voltage (V) or (4)

 

AC load 

current  (  I  )  (5)

 

load  power  factor  (PF)    to  Z-Wave  Controller  after  receive  the 

Meter Get Command from Z-Wave Controller.

 

 
2-2-1 Instant Power Consumption (Watt) of Switch

 

        When receiving Meter Get Command, it will report Meter Report Command to the 

node.

 

 

Summary of Contents for PAN16

Page 1: ...Off button with LED indicator which is used to toggle switch on and off or carry out inclusion exclusion reset or association When first power is applied its LED flashes on and off alternately and repeatedly at 0 5 second intervals It implies that it has not been assigned a node ID and start auto inclusion Auto Inclusion The function of auto inclusion will be executed as long as the switch does no...

Page 2: ...ternately at 2 second intervals By pressing On Off button it will stop flashing temporarily Learning When PAN16 is in learning mode LED flashes on and off alternately and repeatedly at 0 5 second intervals Overload When overload state occurs the Switch is disabled of which LED flashes on and off alternately at 0 2 second intervals Overload state can be cleared by unplugging and reconnecting the Sw...

Page 3: ...e Switch will report its latest status to Z Wave Controller Grouping 1 includes SWITCH_BINARY_REPORT METER_REPORT ALARM_REPORT 2 1 Auto report to Grouping 1 Maximum Node 1 2 1 1 On Off Event Report When on or off state has been changed it will send Binary Switch Report to the node of Grouping 1 Binary Switch Report ON Command Class Switch Binary Switch Binary Report Value 255 0xFF OFF Command Clas...

Page 4: ...learing accumulated power consumption Whenever re start counting the accumulated power consumption is needed you can use Meter Reset Command to clear it Meter Reset Command Command Class Meter Meter Reset 2 2 4 AC load Voltage V When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x04 V Meter Report Command Command ...

Page 5: ... 0 01A 14 5A 3 1 Watt Meter Report Period If the setting is configured for 1hour set value 720 PAN16 will report its instant power consumption to Group1 node every 1 hour The maximum interval to report its instant power consumption is 45 hours 5s 32767 3600 45hr When the setting is 0 PAN16 will disable Watt auto report function The default value is 720 3 2 KWH Meter Report Period If the setting is...

Page 6: ...enever PAN16 is repowered it will check this parameter for if sending a BINARY_SWITCH_ REPORT to the node of group1 or not The default setting is Disable the function 3 12 Adjustable Overload The overload current can be adjustable from 4 5A to 14 5A The default value is 1450 for 14 5A 1450 0 01A 14 5A 4 Protection Command Classes PAN16 supports Protection Command Class version 2 it can protect the...

Page 7: ...1 France type PAN16 2 UK type PAN16 3 Switzerland type PAN16 4 Note Please make sure that the intensity of the plug of the electrical device must be 16A and have same head as the enclosed plug before inserting to the socket ...

Page 8: ...oad occurs Remove the load attached or check max load cannot exceed 13A Resistive load Specification Operating Voltage 220V 240V 50Hz for EU Type Operating Voltage 100V 120V 50Hz 60Hz for US Type Maximum Load Ampere 13A Resistive load PAN16 1 PAN16 2 PAN16 3 Maximum Load Ampere 10A Resistive load PAN16 4 Switzerland Socket Type Germany type PAN16 1 France type PAN16 2 UK type PAN16 3 Switzerland t...

Page 9: ...ccordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the follow...