Problem
Possible cuase
Corrective action
The burner
will not ignite.
The burner flame
is too low.
Carbon build-up
and/or thick
black smoke
is present.
The gas cylinder is frosted over.
An opening is blocked.
The control knob is not in the “ON” position.
(1)
(2)
(3)
The gas pressure is low.
The outdoor temperature is less than 40°F,
and the cylinder is less than 1/4 full.
(1)
(2)
There is dirt or film on the reflector and
burner screen.
The burner is blocked.
(1)
(2)
Wait until gas cylinder warms up and
becomes unfrosted.
Clear the blockage.
Turn the control knob to the
“ON” position.
(1)
(2)
(3)
Turn the cylinder valve off and replace
the cylinder.
Use a full gas cylinder.
Check the burner ports for blockage.
(1)
(2)
(3)
Clean the reflector and burner screen.
Remove any blockage, and clean the
burner inside and outside.
(1)
(2)
TROUBLESHOTTING
15