background image

A

B

C

D

E

G

F

H

PACKAGE CONTENTS

DESCRIPTION

PART

QUANTITY

A

AA
BB
CC
DD

 

Metal shield

1

 

B

 

Glass fixture

1
4

 

C

 

Wide glass

4

D

1

E

Narrow glass
Base

1

F

Door

1

G

Weather cover

4

4

2

2

24

H

Foot glider (PRE-ASSEMBLED)
Bolt (M6 x 5 mm)

Caster with locking device
Ground fixer

Caster

HARDWARE CONTENTS

AA

Bolt (M6 x 5 mm)

X24

X2

Caster

Caster with locking device

Ground fixer

BB

X2

CC

X4

DD

 

NOTE: 

Hardware not shown to actual size.

 

5

LIFE GETS BETTER WITH PHI VILLA

Summary of Contents for E02GS021

Page 1: ...ing to the store please contact our Customer Service service alphamarts com We appreciate the trust and confidence you have placed in PHI VILLA through the purchase of our product We strive to continu...

Page 2: ...Improper installation adjustment alteration service or maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing or serv...

Page 3: ...equent cleaning may be required as necessary It is imperative that the control compartment burners and circulating air passageways of the appliance are kept clean CAUTION The propane gas pressure regu...

Page 4: ...ty of 20 Ibs cylinder Height approximately 18 in Tank Body approximately 12 in diameter Base approximately 8 in diameter The cylinder supply system must be arranged for vapor withdrawl The cylinder us...

Page 5: ...E Narrow glass Base 1 F Door 1 G Weather cover 4 4 2 2 24 H Foot glider PRE ASSEMBLED Bolt M6 x 5 mm Caster with locking device Ground fixer Caster HARDWARE CONTENTS AA Bolt M6 x 5 mm X24 X2 Caster C...

Page 6: ...en any mechanical or propane fueled equipment is involved These precautions are necessary when using storing and servicing Using this equipment with the respect and caution demanded will reduce the po...

Page 7: ...opane vapors are heavier than air and can accumulate in low places If you smell gas leave the area immediately Never install or remove propane cylinder while heater is lighted near flame other ignitio...

Page 8: ...set up for vapor withdrawal Store or use propane gas in compliance with local ordinances and codes or with ANS NFPA 58 Turn off propane when not in use Alert children and adults to the hazards of high...

Page 9: ...on the ground fixer DD with the corresponding holes on the base E then insert the bolt on foot glider H into the holes and hand tighten them clockwise To prevent heater from strong wind or incline gr...

Page 10: ...much to avoid the glass pieces being damaged See Figure 5 5 Insert the four wide glass C into the L clips which have been welded together with table top then attach them with bolts AA using the Phill...

Page 11: ...ecure the cylinder by tightening clockwise the retention point found on the cylinder holder so that the cylinder cannot move from side to side or fall down Connect the regulator screw the black handle...

Page 12: ...rol panel to access the battery compartment The ignitor module requires one AAA size battery BATTERY IS NOT INCLUDED OFF APG MAX M X 1 AAA 1 5V IGNITOR Encendedor ON MIN ENC M N LIGHTING INSTRUCTIONS...

Page 13: ...in gas control knob slightly and turn to OFF To perform a leak test gas valve regulator hose connection Figure 13 inlet tube bellows connection Figure 14 Figure 15 gas control knob ignition button OFF...

Page 14: ...vapors and liquids b Do not obstruct the flow of combustion and ventilation air c Keep the ventilation opening s of the cylinder enclosure free and clear from debris 3 Air flow must be unobstructed Ke...

Page 15: ...and the cylinder is less than 1 4 full 1 2 There is dirt or film on the reflector and burner screen The burner is blocked 1 2 Wait until gas cylinder warms up and becomes unfrosted Clear the blockage...

Page 16: ...7 606 2818 Questions problems missing parts Before returning to the store please contact our Customer Service service alphamarts com Heater Burner all mechanical parts and fittings to control panel an...