background image

16

Step 4. Use

Now press ALL three buttons on the controller at the same time.

Pressing this button reduces the flow setting by 10.

The controller will indicate this reduction:

If the pairing is successful the LED segments will stop circling and the ‘Fob’ will 

disappear from the controller display. Your fob should now operate the controller as 

described in 

1. Fob Overview

.

If the pairing is unsuccessful turn the controller off for 30 seconds then on again and 

repeat the steps above.

Pressing this button increases the flow setting by 10.

The controller will indicate this increase:

Step 4. Use Cont’d

Pressing and holding this button will start an auto calibration on your controller. 

(Ensure flow is set to your desired value e.g. 50).

All LEDs on the segment light to show auto calibration has started, the controller 

will indicate ‘AUt’.

When the controller has calibrated one LED on the segment will light to show 

this. ‘CAL’ will disappear from the controller display.

Pressing this button starts and stops the pump. If the pump is running press the 

button once to stop. All LEDs on the segment will light, the pump will stop and 

controller indicates ‘StP’.

If the pump is stopped press the button once to start.

A single LED on the segment will light, the pump will start and controller indi-

cates the current flow. e.g. ‘30’.

Summary of Contents for Shadow RODI-40 Manual

Page 1: ......

Page 2: ......

Page 3: ...em 17 How to Replace Cartridges 17 How to Flush RO Filters 17 How to Protect Your Hoses 18 Care Maintenance and Replacement of Cartridges 18 Carbon Cartridge 18 Reverse Osmosis Cartridge 18 DeIonizing Cartridge 18 Troubleshooting 19 Plumbing 19 Electrical 19 How to Connect the Fob hockey puck to Controller on the Unit 19 Pump is Cycling on and Off Rapidly 20 Trouble Shooting Flow Diagram 21 Recomm...

Page 4: ......

Page 5: ......

Page 6: ...4 ...

Page 7: ...s an RODI 40 or a dual reverse osmosis cartridge system RODI 80 Both the 40 or the 80 designate the overall length of reverse osmosis cartridge on the system which is indicated in inches DO NOT DRINK PURE WATER NOT FOR HUMAN OR ANIMAL CONSUMPTION Benefits of Pure Water Water spots left behind on windows or glass from dried mineral build up are a neg ative of soft washing The pure water system filt...

Page 8: ...he tank is filled to the desired level turn the power switch to 2 to spray You can make pure water WHILE ALSO spraying by turning the power switch to 1 AND 2 5 Use trigger sprayer to apply to desired surface or supplu a water fed pole es Auto System Description The auto version has two 12 volt pumps with a digital controller This unit is fully automatic with bluetooth remote capabilities The contr...

Page 9: ...MP controller it will not work with air in the system Always prime your system before starting work If air in the system causes false dead end detection increase Cal value less sensitive Do not set the Cal value too high Setting it higher than necessary places extra strain on both the pump and the controller in a dead end situation This can result in dam age to both the pump and your controller Sp...

Page 10: ... on the RO outlet or DI outlet TDS Sensor Battery Pump Battery Pump Autofill Solenoid Valve 12V Make sure correct fuse is fitted inline Failure to do so will ersult in damage to the unit Observe correct battery polarity Failure to do so will resultin damage to the unit All controller images operation and functionality are Copyright 2020 Spring Europe Ltd all rights reserved ...

Page 11: ...t Auto Cal starts from C99 After several moments the calculated CAL value e g C50 will be displayed and the controller is ready to use Press enter to exit calibration The CAL value can be adjusted manually by following the same steps and adjusting the CAL value by pressing the up or down button instead of using AUt To enable or disable the low battery cut off that stops your pump when the battery ...

Page 12: ...n demand FOd menu indicating a high TDS level has stopped the system The controller will turn the pump back on to resume pumping if the TDS level drops below the TDS cut off value NOTE When the controller is first turned on the TDS cut off is disabled for approxi mately 60 seconds to allow any dirty water above TDS cut off value to be pumped out To adjust TDS cut off value enter the set up menu by...

Page 13: ...xt item Set Up Autoflush Message Description Controller Messages An error has occured while using AutoCal This will happen when the motor is not connected or the enter button has been pressed to cancel it Controller Messages This message will start to flash when the battery is low 11 0V If the battery is below 10 5V the pump will be disabled to protect the battery unless low battery cutoff is disa...

Page 14: ...yed Press enter again to monitor TDS reading A TDS reading greater than 50ppm will display HI high Press enter again to return to the current flow rate To turn the controller off press and hold enter To start filling the tank press and hold the up and down buttons This will activate the solenoid valve allowing water to fill the tank until the float switch detects that the tank is full Operation Ta...

Page 15: ...nk is filling the display will flash FIL To manually stop the tank filling press and hold the up and down buttons again The display will stop showing FIL Fill on demand is effectively a tank level control that keeps the tank topped up to the level switch The solenoid valve will be turned off if the unit detects a low battery below 10 5V ...

Page 16: ...o 40 o C Pump Decrease Each press will reduce pump flow by 10 LED segments indicate this Auto Calibrate Press and hold until whole LED segment lights One LED lights to indicate calibration has finished Pump Increase Each press will increase pump flow by 10 LED segments indicate this DISCLAIMER THE MANUFACTURER RESERVES THE RIGHT TO MAKE CHANGES TO ANY PRODUCT HEREIN TO IMPROVE RELIABILITY FUNCTION...

Page 17: ...ns on the fob If the fob is charged and working the LED segments will appear to circle around the fob The controller will respond by displaying FOb To Charge Plug in micro USB phone charger or similar to the charging connector Charging LED is red when charging Charging LED is green when charged Charging LED DO NOT IMMERSE FOB IN WATER Doing so will result in damage to the unit DO NOT LEAVE IN DIRE...

Page 18: ...ill indicate this increase Step 4 Use Cont d Pressing and holding this button will start an auto calibration on your controller Ensure flow is set to your desired value e g 50 All LEDs on the segment light to show auto calibration has started the controller will indicate AUt When the controller has calibrated one LED on the segment will light to show this CAL will disappear from the controller dis...

Page 19: ... reach an acceptable level Flush RO filters or consider replacing the DI cartridge Filter replacement and flush How to Flush RO Filters See picture 1 and 2 ň Manual System ʼn Open the back flush valve ʼn Turn your water supply on and allow water to run through the machine for about 10 minutes ʼn Turn off the water supply ʼn Close the back flush valve to return to normal operating position ň Powered Sy...

Page 20: ...solids of minerals in the water to zero Reverse Osmosis cartridges will need to be backflushed regularly depending on frequency of use and quality of water Please see backflush instruc tions depending on your model The RO cartridges are back flushable and have a longer service life than the Carbon or DeIonizing cartridges DeIonizing Cartridge DeIonizing Cartridge is a 40 cartridge that is responsi...

Page 21: ...inch quick connects Electrical If the digital Controller does not activate or light up it means it is a blown fuse Re place with 30 amp fuse which is located near the batteries Tank doesn t fill Check fuse replace with 30 amp fuse If you see the FUL notification on display and the tank is not full check for loose wire on float switch or a bad float switch If the tank won t fill the battery may be ...

Page 22: ...tch failure If the pump starts to cycle while spraying auto set flow to a lower value or while making pure water increase the pump shutoff pressure To do this use a 1 16 allen wrench turn the screw on the pressure switch clockwise to increase shut off pressure Observe pressure gauges so you can adjust the pressure switch on the pump properly powered only The powered system has two pressure gauges ...

Page 23: ...WORKING NO STILL NOT WORKING Soft reset press and hold all four buttons until lights appear Hard reset open case and disconnect battery for 10 seconds WFP Link fob is broken Did the message FOb appear on the controller Hard reset controller disconnect the power for 10 seconds Either controller or fob is not working WFP Link is working RETRY RETRY RETRY ...

Page 24: ...g and Care of Your Batteries Deep cycle batteries require daily charging Make sure to visit your battery manu facturer s website for care and maintenance guidelines Poorly charged batteries will diminish the performance of the modules BATTERY VOLTAGE STATE OF CHARGE TABLE State of Charge Sealed of Flooded Lead Acid Battery Voltage AGM Battery Voltage 100 12 70 12 80 75 12 40 12 60 50 12 20 12 30 2...

Page 25: ...51 522 Blend 6X 50 0 Blend 6X 100 0 Rinse DC Plus 50 129 59 546 248 Rinse DC Plus 100 185 84 1019 462 Phantom Shadow RODI 50 170 77 620 281 Phantom Shadow RODI 100 209 95 1069 485 Power Wash 50 255 116 672 305 Power Wash 100 311 141 1145 519 Power Washer Alone 206 93 Reels 12 U Frame 25 11 105 48 12 Full Frame 27 12 107 49 12 Electric 49 22 129 59 18 U Frame 28 13 108 49 18 Full Frame 30 14 110 50...

Page 26: ... NA Single Module Extension NA NA Aluminum Accessories Ladder Rack Standard NA NA Ladder Rack Commercial NA NA Reel Stand Light 25 11 NA NA Reel Stand Extension 18 8 NA NA Battery Tray 5 2 NA NA Graduated Tank Strap 17 8 NA NA Cradle Ladder Rack Combo 95 43 NA NA Hose Hanger 3 1 NA NA Flat Surface Cleaner Rack 34 15 NA NA Tanks with Graduated Straps 6 Gallon Saddle 17 8 77 35 7 Gallon Saddle 18 8 ...

Page 27: ...nty claim needs to be made claims should be filed with the distributor from which you purchased your Phantom Window Works product The distributor will contact Phantom Window Works for warranty parts to repair or replace the broken or defective component WARNING These materials may contain a chemical known to the State of California to cause birth defects or other reproductive harm www P65Warnings ...

Page 28: ......

Reviews: