9
Step 2. Set Up - Auto Calibrate
Connect your hose and brush to the pump.
Turn on the controller by pressing the up or down button. Keep the button held until
the display lights up.
Press up until the display shows 30.
Press and hold the up and enter buttons to calibrate. CAL will be displayed.
Press the down button to select Auto Cal, AUt will be displayed. Press the enter
button to start. Auto Cal starts from C99.
After several moments the calculated CAL value (e.g. C50) will be displayed and the
controller is ready to use. Press enter to exit calibration.
The CAL value can be adjusted manually by following the same steps and adjusting
the CAL value by pressing the up or down button instead of using AUt.
To enable or disable the low battery cut-off (that stops your pump when the battery
voltage is below 10.5V) press and hold the down and enter buttons on PUMP 1.
Then use the up or down button to select ON or OFF. Press enter to save.
NOTE:
‘
ON
’ keeps your battery protected.
,
+
,
+