PFT Conveying Pump ZP 3 XL MIX Part 2 Overview – Operation - Spare Parts Lists
Troubleshooting Tasks
30
Fehler! Formatvorlage nicht definiert.
10.4 Safety
Personnel
The work described here for eliminating a fault can be done by
the operator provided it is not indicated otherwise.
Several tasks may be executed only by specially trained
professional personnel or exclusively by the manufacturer; this
is separately indicated in the description of the individual faults.
Work on the electrical system may only be carried out by
electricians.
Personal Protective Equipment
Wear the following protective gear when doing all kinds of
maintenance work:
Safety clothing
Protective goggles, safety gloves, safety shoes, hearing
protection.
10.5 Troubleshooting Table
Fault
Possible cause
Fault elimination
Elimination by
Main switch not activated
Activate the main switch
Operator
Power line not in order
Repair the power line
Service fitter
Protection switch was released
Reset the FI-safety switch
Service fitter
Motor protection switches
released
In the switch cabinet, turn the motor
protection switch to Position 1
Service fitter
"Operation button On" not pressed Press "Operation button On"
Operator
Protection defective
Change protection
Service fitter
Control connector is missing
Plug in the control connector
Operator
Machine does
not start:
Power
Safety fuse is defective
Replace the safety fuse
Service fitter
Too much solidified material in the
container. Possible tunnel
formation
Attention:
Main switch
OFF
- pull
off the main power cable. Empty the
material container to half level. Start
the machine anew.
Operator
Hardened material blocks, the
pump unit (rotor/stator)
Attention:
Main switch
OFF
- pull
off the main power cable. Dismount
the pump, clean it and mount it
back.
Operator
Machine does
not start:
Material
Too dry material in the pump
Attention:
Main switch
OFF
- pull
off the main power cable. Clean the
material container
Operator
Machine does,
not start:
Fine fuse on the transformer
defective
Replace the fine fuse
Service fitter
Pump motor defective
Replace the pump motor
Service fitter
pump does not
start
Connection cable defective
Replace the connection cable
Service fitter