PFT RITMO
powercoat 110V
Operating Instructions
Last updated 12.2006
Knauf PFT GmbH & Co. KG
44
Program Group Parameters Frequency Power Flex RITMO 110V 1Phase
Parameter
Display
P031
Motor NP Volts
230 V
Set to the motor Nameplate
rated volts
P032
Motor NP Hertz
50 Hz
Set to the motor Nameplate
rated frequency
P033
Motor OL Current
5.8 A
Set to the maximum allowable
motor current
P034
Minimum Freq
20 Hz
Sets the lowest frequency the
drive will output continuously
P035
Maximum Freq
87 Hz
Sets the highest frequency the
drive will output
P036
Start Source
2 = 2-Wire
2
Sets the control scheme used
to start the drive
P038
Speed Reference
2
Sets the source of the speed
reference to the drive
P039
Accel Time 1
1.5 sec
Sets the rate of accel for all
speed increases
P040
Decel Time 1
1.5 sec
Sets the rate of decel for all
speed decreases
P041
Reset To Defaults
0= Idle State
1= Reset Defaults
0
Resets all parameter values to
factory defaults
A055
Relay Out Sel
2
Motor Running