Safety
Revision 4 | Operating instructions sample cleaner SLN 4
11 | 40
2.2
Interfaces at sample cleaner SLN 4
Figure 2: Interfaces
Item Name
Item Name
1
Filler hole
7
Outlet - Cleaned sample
2
ON/OFF control switch
8
Outlet for small grain (4. Grading sieve)
3
Control switch - Manually open the
bottom of the deawner
9
Outlet for sand, weeds and coarse dirt particles
4
Potentiometer - Deawner time
10
Outlet for small grain (3. Grading sieve)
5
Locking lever for base of deawner
11
Service holes (right and left on the casing)
6
Door
12
Cyclone
2.3
Operating and hazard areas associated with the machine
Operating area
Ensure a sufficient working height (depending on the body size of the operating personnel) of
approximately 60-65 cm. For this, a suitable base frame is necessary so that the operating personnel can
access the collecting pans ergonomically.
Hazard area
The entire area of one metre around the machine is dangerous during adjustment, maintenance and
repair work. The swivelling range of the self-opening door as well as of the filler cap must also be taken
into consideration.
Do not keep any objects around the machine.
2.4
Operating and maintenance personnel
Operating and maintenance personnel are responsible for transport, assembly, installation, operation,
adjustment and cleaning of the machine as well as for fault rectification.
1.
Sample cleaner
SLN 4
is allowed to be operated by authorised and instructed persons only.
2.
The responsibilities associated with operating the machine must be clearly defined and adhered to so