Connection "Profibus"
15
5.3.4
control-/status byte
5.3.5
Parameterization data
To set a configuration that deviates from the delivery state (="start-up configuration") or
to define actions in the Profibus "fail-safe" state and/or when response monitoring lapses
(e.g. master fails) (="fail-safe action"), up to six parameters, described with predefined
values on a case-by-case basis, can be defined for all modules. Eight-byte parameter-
ization data are added per parameter in the following format (undefined points to be as-
signed 0):
5.4
Expanded diagnostics data
*Device errors and warnings are anchored in the electronic drive unit
.
** see PPO1
Bit
Output data (1 byte)
Input data (1 byte)
7
Error acknowledgement, -> automatic trip
switch (switching back on only by pumping sta-
tion off and back on)
Warning, general
6
Standby
Warning, temperature
5
Enable venting
Operation: No error, pumping station and motor
pump are on, no automatic trip switch
4
Heating
Rotation speed switch point attained
3
-
Errors
2
Enable process data (control byte):
0 = ignore
1 = accept
0
1
-
Pump rotates
0
Pumping station
Set rotation speed attained
Byte
Description
0, bit 7
0: Parameter for "start-up configuration"
1: Parameter for "fail-safe action"
0, bit 6
0: Parameter value is integer
1: Parameter value rounded to nearest number to IEEE 754
2-3
Parameter number
4-7
Parameter value
Designation
Example of module designation
Module without additional parameter
PPO1, PPO3, control-/status word, control-/status byte
Module with one to six additional parame-
ters
PPO1 (1 prm) ... (6prm)
PPO1 (1 prm) ... (6prm)
control-/status word (1 prm) ... (6prm)
control-/status byte (1 prm) ... (6prm)
Byte
Designation
Description
1-6
Standard diagnostics Profibus
Defined by Profibus specification
7
Length of the external diagnostics data
8-36
Reserved
37-38 Current error code
0: No error
1-999: Device error*
1001-1999: Device warning 1-999*
2000: Unrecognised module
3xxx: Parameterization data incorrect in accor-
dance with error number in the parameter chan-
nel**
39-69 Internal state