6 Interfaces
6.1 Interface overview
accessory
remote
1
2
3
4
5
C
D
6
7
Fig. 10:
Interfaces of the electronic drive unit
1 Mains connection ACin, C14
5
LED operating mode display
2 Remote connection
6
Accessory connection "C"
3 Stand-by button
7
Accessory connection "D"
4 On/Off button
6.2 "Remote" interface
The 15-pin sub-D connection with the "
remote
" designation offers the possibility to operate the electron-
ic drive unit via remote control. The following specifications are the factory settings for the electronic
drive unit. They can be configured with the Pfeiffer Vacuum parameter set.
► Utilize the screened plug and cable.
1
2
3
4
5
24 V DC*
RS 485 +
RS 485 -
n.c.
2
3
4
5
6
7
10
11
8
9
12
13
14
15
1
DI
n.c.
DI2
DI
DI
24 V DC* (V+)
DO1
DO2
RS 485 D+
RS 485 D-
FE
2
3
4
5
6
7
10
11
8
9
12
13
14
15
1
S2
S1
n. c.
n. c.
n.c.
n.c.
Fig. 11:
Connection diagram of 15-pin "remote" connection